Agreement between Electrical Cardiometry and Pulmonary Artery Thermodilution for Measuring Cardiac Output in Isoflurane-Anesthetized Dogs

被引:5
|
作者
Paranjape, Vaidehi V. [1 ]
Henao-Guerrero, Natalia [1 ]
Menciotti, Giulio [1 ]
Saksena, Siddharth [2 ]
Agostinho, Manuela [1 ]
机构
[1] Virginia Maryland Coll Vet Med, Dept Small Anim Clin Sci, 205 Duck Pond Dr, Blacksburg, VA 24061 USA
[2] Virginia Polytech Inst & State Univ, Dept Civil & Environm Engn, 750 Drillfield Dr, Blacksburg, VA 24061 USA
来源
ANIMALS | 2023年 / 13卷 / 08期
关键词
canine; anesthesia; hemodynamics; monitoring; hemorrhage; hypovolemia; colloids; electrical velocimetry; noninvasive; blood transfusion; FLUID RESPONSIVENESS; PREEJECTION PERIOD; SPINAL-ANESTHESIA; VELOCIMETRY; HEART; HEMODYNAMICS; METAANALYSIS; SEVOFLURANE; MONITORS; ABILITY;
D O I
10.3390/ani13081420
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Simple Summary Using general anesthesia on animals causes significant changes to the heart and blood vessels that disrupt normal cardiovascular performance. Blood pressure (BP) is used for closely monitoring hemodynamics in anesthetized animals. However, BP is affected by various factors and may not always accurately correlate with the total body blood flow. Pulmonary artery thermodilution (PATD) is the gold standard for cardiac output (CO) measurements, but, due to the high risks associated with its invasiveness, it is not performed in clinical settings. This study evaluates noninvasive electrical cardiometry's (EC) performance in measuring CO and other hemodynamic variables in healthy anesthetized dogs during acute blood volume manipulation. The EC measurements consistently underpredict the CO values as compared with PATD, but have a better performance when acute blood loss occurs. Even though the EC readings have a slightly higher error than the accepted error, this method is very good at showing trends in the CO measured using PATD. Other EC-derived variables are able to closely track the changes in the CO measured using PATD. In clinics, noninvasive EC may benefit the patient care quality for anesthetized dogs by monitoring the trends in hemodynamics and guiding anesthetists to diagnose and treat cardiovascular complications. In animals, invasive pulmonary artery thermodilution (PATD) is a gold standard for cardiac output (CO) monitoring, but it is impractical in clinical settings. This study evaluates the agreement between PATD and noninvasive electrical cardiometry (EC) for measuring CO and analyzes the other EC-derived hemodynamic variables in six healthy anesthetized dogs subjected to four different hemodynamic events in a sequential order: (1) euvolemia (baseline); (2) hemorrhage (33% blood volume loss); (3) autologous blood transfusion; and (4) 20 mL/kg colloid bolus. The CO measurements obtained using PATD and EC are compared using Bland-Altman analysis, Lin's concordance correlation (LCC), and polar plot analysis. Values of p < 0.05 are considered significant. The EC measurements consistently underpredict the CO values as compared with PATD, and the LCC is 0.65. The EC's performance is better during hemorrhage, thus indicating its capability in detecting absolute hypovolemia in clinical settings. Even though the percentage error exhibited by EC is 49.4%, which is higher than the standard (<30%), EC displays a good trending ability. Additionally, the EC-derived variables display a significant correlation with the CO measured using PATD. Noninvasive EC may have a potential in monitoring trends in hemodynamics in clinical settings.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Comparison of pulmonary artery and transpulmonary thermodilution cardiac output measurements in unsedated newborn calves
    Kutter, Annette P. N.
    Schefer, Rahel S. Jud
    Bircher, Barbara
    Bleul, Uli
    Bettschart-Wolfensberger, Regula
    VETERINARY ANAESTHESIA AND ANALGESIA, 2015, 42 (06) : 614 - 622
  • [42] Cardiac output-pulse contour analysis vs. pulmonary artery thermodilution
    Ostergaard, M.
    Nielsen, J.
    Rasmussen, J. P.
    Berthelsen, P. G.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (09) : 1044 - 1049
  • [43] Arterial thermodilution:: an alternative to pulmonary artery catheter for cardiac output assessment in burn patients
    Holm, C
    Melcer, B
    Hörbrand, F
    von Donnersmarck, GH
    Mühlbauer, W
    BURNS, 2001, 27 (02) : 161 - 166
  • [44] TECHNIC FOR MEASURING CARDIAC OUTPUT DIRECTLY BY CANNULATION OF THE PULMONARY ARTERY
    SEELY, RD
    GREGG, DE
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1950, 73 (02): : 269 - 270
  • [45] THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS BY INJECTION IN PULMONARY-ARTERY VS CVP CATHETER
    MARTIN, C
    SAUX, P
    AUFFRAY, JP
    FULACHIER, V
    SETBON, F
    GOUIN, F
    CRITICAL CARE MEDICINE, 1983, 11 (06) : 460 - 461
  • [46] Relation between cardiac frequency and its output in non anesthetized dogs.
    Lequime, J
    Denolin, H
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1938, 129 : 899 - 901
  • [47] Agreement between ccNexfin CO-trek cardiac output and intermittent cold-bolus pulmonary thermodilution in a prospective multicenter study
    Sperna Weiland, Nicolaas H.
    de Wever, Jim W.
    van Duivenvoorde, Yoni
    Boer, Christa
    Mitrev, Ludmil
    Muntazar, Muhammad
    Patel, Kinjal
    Hollmann, Markus W.
    Preckel, Benedikt
    MINERVA ANESTESIOLOGICA, 2018, 84 (04) : 473 - 480
  • [48] Ventilation distribution assessed with electrical impedance tomography and the influence of tidal volume, recruitment and positive end-expiratory pressure in isoflurane-anesthetized dogs
    Ambrosio, Aline M.
    Carvalho-Kamakura, Tatiana P. A.
    Ida, Keila K.
    Varela, Barbara
    Andrade, Felipe S. R. M.
    Faco, Lara L.
    Fantoni, Denise T.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2017, 44 (02) : 254 - 263
  • [49] Letter to the editor in response to "Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis"
    Fellery de Lange
    Inge T. Bootsma
    E. Christiaan Boerma
    Critical Care, 25
  • [50] MEASURING CARDIAC-OUTPUT UNDER POSITIVE END-EXPIRATORY PRESSURE WITH THE NONINVASIVE CONTINUOUS CARDIAC-OUTPUT MONITOR NCCOM-3 BY BIOIMPEDANCE AS COMPARED WITH THERMODILUTION MEASUREMENTS - A STUDY IN ANESTHETIZED DOGS
    WEBER, J
    HEIDELMEYER, CF
    KUBATZ, E
    BRUCKNER, JB
    ANAESTHESIST, 1986, 35 (12): : 744 - 747