Agreement between Electrical Cardiometry and Pulmonary Artery Thermodilution for Measuring Cardiac Output in Isoflurane-Anesthetized Dogs

被引:5
|
作者
Paranjape, Vaidehi V. [1 ]
Henao-Guerrero, Natalia [1 ]
Menciotti, Giulio [1 ]
Saksena, Siddharth [2 ]
Agostinho, Manuela [1 ]
机构
[1] Virginia Maryland Coll Vet Med, Dept Small Anim Clin Sci, 205 Duck Pond Dr, Blacksburg, VA 24061 USA
[2] Virginia Polytech Inst & State Univ, Dept Civil & Environm Engn, 750 Drillfield Dr, Blacksburg, VA 24061 USA
来源
ANIMALS | 2023年 / 13卷 / 08期
关键词
canine; anesthesia; hemodynamics; monitoring; hemorrhage; hypovolemia; colloids; electrical velocimetry; noninvasive; blood transfusion; FLUID RESPONSIVENESS; PREEJECTION PERIOD; SPINAL-ANESTHESIA; VELOCIMETRY; HEART; HEMODYNAMICS; METAANALYSIS; SEVOFLURANE; MONITORS; ABILITY;
D O I
10.3390/ani13081420
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Simple Summary Using general anesthesia on animals causes significant changes to the heart and blood vessels that disrupt normal cardiovascular performance. Blood pressure (BP) is used for closely monitoring hemodynamics in anesthetized animals. However, BP is affected by various factors and may not always accurately correlate with the total body blood flow. Pulmonary artery thermodilution (PATD) is the gold standard for cardiac output (CO) measurements, but, due to the high risks associated with its invasiveness, it is not performed in clinical settings. This study evaluates noninvasive electrical cardiometry's (EC) performance in measuring CO and other hemodynamic variables in healthy anesthetized dogs during acute blood volume manipulation. The EC measurements consistently underpredict the CO values as compared with PATD, but have a better performance when acute blood loss occurs. Even though the EC readings have a slightly higher error than the accepted error, this method is very good at showing trends in the CO measured using PATD. Other EC-derived variables are able to closely track the changes in the CO measured using PATD. In clinics, noninvasive EC may benefit the patient care quality for anesthetized dogs by monitoring the trends in hemodynamics and guiding anesthetists to diagnose and treat cardiovascular complications. In animals, invasive pulmonary artery thermodilution (PATD) is a gold standard for cardiac output (CO) monitoring, but it is impractical in clinical settings. This study evaluates the agreement between PATD and noninvasive electrical cardiometry (EC) for measuring CO and analyzes the other EC-derived hemodynamic variables in six healthy anesthetized dogs subjected to four different hemodynamic events in a sequential order: (1) euvolemia (baseline); (2) hemorrhage (33% blood volume loss); (3) autologous blood transfusion; and (4) 20 mL/kg colloid bolus. The CO measurements obtained using PATD and EC are compared using Bland-Altman analysis, Lin's concordance correlation (LCC), and polar plot analysis. Values of p < 0.05 are considered significant. The EC measurements consistently underpredict the CO values as compared with PATD, and the LCC is 0.65. The EC's performance is better during hemorrhage, thus indicating its capability in detecting absolute hypovolemia in clinical settings. Even though the percentage error exhibited by EC is 49.4%, which is higher than the standard (<30%), EC displays a good trending ability. Additionally, the EC-derived variables display a significant correlation with the CO measured using PATD. Noninvasive EC may have a potential in monitoring trends in hemodynamics in clinical settings.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Measuring cardiac output during cardiac catheterization: Marked differences between direct fick cardiac output and thermodilution
    Zahn, R
    Thoma, S
    Gitt, AK
    Lotter, R
    Seidl, K
    Zander, M
    Senges, J
    HERZ KREISLAUF, 1996, 28 (7-8): : 232 - 235
  • [32] Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
    S. G. Sakka
    K. Reinhart
    A. Meier-Hellmann
    Intensive Care Medicine, 1999, 25 : 843 - 846
  • [33] Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis
    Karim Kouz
    Frederic Michard
    Alina Bergholz
    Christina Vokuhl
    Luisa Briesenick
    Phillip Hoppe
    Moritz Flick
    Gerhard Schön
    Bernd Saugel
    Critical Care, 25
  • [34] Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
    Sakka, SG
    Reinhart, K
    Meier-Hellmann, A
    INTENSIVE CARE MEDICINE, 1999, 25 (08) : 843 - 846
  • [35] Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable
    Moller-Sorensen, H.
    Graeser, K.
    Hansen, K. L.
    Zemtsovski, M.
    Sander, E. M.
    Nilsson, J. C.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2014, 58 (01) : 80 - 88
  • [36] Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis
    Kouz, Karim
    Michard, Frederic
    Bergholz, Alina
    Vokuhl, Christina
    Briesenick, Luisa
    Hoppe, Phillip
    Flick, Moritz
    Schon, Gerhard
    Saugel, Bernd
    CRITICAL CARE, 2021, 25 (01)
  • [37] Assessment of transpulmonary thermodilution, ultrasound dilution, and esophageal Doppler against direct pulmonary artery flow for cardiac output monitoring in anesthetized cats
    Liao, Pen-Ting
    Tillson, Michael
    Clark-Price, Stuart
    Kuo, Kendon
    Gerken, Katherine
    Claret, Aina
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2025, 86 (03)
  • [38] Effects of rocuronium bromide on globe position and respiratory function in isoflurane-anesthetized dogs: a comparison between three different dosages
    Briganti, Angela
    Barsotti, Giovanni
    Portela, Diego A.
    Di Nieri, Camilla
    Breghi, Gloria
    VETERINARY OPHTHALMOLOGY, 2015, 18 (02) : 89 - 94
  • [39] The differential contribution of vascular gap junctions to pial and penetrating artery dilation induced by forepaw electrical stimulation in isoflurane-anesthetized rats
    Watanabe, N.
    Sasaki, S.
    Masamoto, K.
    Hotta, H.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 242 - 242
  • [40] Measurement of cardiac output by transpulmonary arterial thermodilution using a long radial artery catheter. A comparison with intermittent pulmonary artery thermodilution
    Orme, RML
    Pigott, DW
    Mihm, FG
    ANAESTHESIA, 2004, 59 (06) : 590 - 594