Agreement between Electrical Cardiometry and Pulmonary Artery Thermodilution for Measuring Cardiac Output in Isoflurane-Anesthetized Dogs

被引:5
|
作者
Paranjape, Vaidehi V. [1 ]
Henao-Guerrero, Natalia [1 ]
Menciotti, Giulio [1 ]
Saksena, Siddharth [2 ]
Agostinho, Manuela [1 ]
机构
[1] Virginia Maryland Coll Vet Med, Dept Small Anim Clin Sci, 205 Duck Pond Dr, Blacksburg, VA 24061 USA
[2] Virginia Polytech Inst & State Univ, Dept Civil & Environm Engn, 750 Drillfield Dr, Blacksburg, VA 24061 USA
来源
ANIMALS | 2023年 / 13卷 / 08期
关键词
canine; anesthesia; hemodynamics; monitoring; hemorrhage; hypovolemia; colloids; electrical velocimetry; noninvasive; blood transfusion; FLUID RESPONSIVENESS; PREEJECTION PERIOD; SPINAL-ANESTHESIA; VELOCIMETRY; HEART; HEMODYNAMICS; METAANALYSIS; SEVOFLURANE; MONITORS; ABILITY;
D O I
10.3390/ani13081420
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Simple Summary Using general anesthesia on animals causes significant changes to the heart and blood vessels that disrupt normal cardiovascular performance. Blood pressure (BP) is used for closely monitoring hemodynamics in anesthetized animals. However, BP is affected by various factors and may not always accurately correlate with the total body blood flow. Pulmonary artery thermodilution (PATD) is the gold standard for cardiac output (CO) measurements, but, due to the high risks associated with its invasiveness, it is not performed in clinical settings. This study evaluates noninvasive electrical cardiometry's (EC) performance in measuring CO and other hemodynamic variables in healthy anesthetized dogs during acute blood volume manipulation. The EC measurements consistently underpredict the CO values as compared with PATD, but have a better performance when acute blood loss occurs. Even though the EC readings have a slightly higher error than the accepted error, this method is very good at showing trends in the CO measured using PATD. Other EC-derived variables are able to closely track the changes in the CO measured using PATD. In clinics, noninvasive EC may benefit the patient care quality for anesthetized dogs by monitoring the trends in hemodynamics and guiding anesthetists to diagnose and treat cardiovascular complications. In animals, invasive pulmonary artery thermodilution (PATD) is a gold standard for cardiac output (CO) monitoring, but it is impractical in clinical settings. This study evaluates the agreement between PATD and noninvasive electrical cardiometry (EC) for measuring CO and analyzes the other EC-derived hemodynamic variables in six healthy anesthetized dogs subjected to four different hemodynamic events in a sequential order: (1) euvolemia (baseline); (2) hemorrhage (33% blood volume loss); (3) autologous blood transfusion; and (4) 20 mL/kg colloid bolus. The CO measurements obtained using PATD and EC are compared using Bland-Altman analysis, Lin's concordance correlation (LCC), and polar plot analysis. Values of p < 0.05 are considered significant. The EC measurements consistently underpredict the CO values as compared with PATD, and the LCC is 0.65. The EC's performance is better during hemorrhage, thus indicating its capability in detecting absolute hypovolemia in clinical settings. Even though the percentage error exhibited by EC is 49.4%, which is higher than the standard (<30%), EC displays a good trending ability. Additionally, the EC-derived variables display a significant correlation with the CO measured using PATD. Noninvasive EC may have a potential in monitoring trends in hemodynamics in clinical settings.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Performance of four cardiac output monitoring techniques vs. intermittent pulmonary artery thermodilution during a modified passive leg raise maneuver in isoflurane-anesthetized dogs
    Paranjape, Vaidehi V.
    Henao-Guerrero, Natalia
    Menciotti, Giulio
    Saksena, Siddharth
    FRONTIERS IN VETERINARY SCIENCE, 2023, 10
  • [2] Evaluation of agreement and trending ability between transpulmonary thermodilution and calibrated pulse contour and pulse power cardiac output monitoring methods against pulmonary artery thermodilution in anesthetized dogs
    Kutter, Annette P. N.
    Bettschart-Wolfensberger, Regula
    Romagnoli, Noemi
    Bektas, Rima N.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2016, 26 (04) : 531 - 540
  • [3] Evaluation of Electrical Cardiometry for Measuring Cardiac Output and Derived Hemodynamic Variables in Comparison with Lithium Dilution in Anesthetized Dogs
    Paranjape, Vaidehi V.
    Garcia-Pereira, Fernando L.
    Menciotti, Giulio
    Saksena, Siddharth
    Henao-Guerrero, Natalia
    Ricco-Pereira, Carolina H.
    ANIMALS, 2023, 13 (14):
  • [4] Comparison of Transpulmonary Thermodilution and Calibrated Pulse Contour Analysis with Pulmonary Artery Thermodilution Cardiac Output Measurements in Anesthetized Dogs
    Garofalo, N. A.
    Teixeira-Neto, F. J.
    Rodrigues, J. C.
    Cerejo, S. A.
    Aguiar, A. J. A.
    Becerra-Velasquez, D. R.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2016, 30 (04) : 941 - 950
  • [5] Agreement of cardiac output measurements by esophageal Doppler and transesophageal echocardiography with intermittent pulmonary artery thermodilution during pharmacologic manipulation of hemodynamics in anesthetized dogs
    Paranjape, Vaidehi V.
    Pereira, Fernando. L. Garcia
    Menciotti, Giulio
    Saksena, Siddharth
    Guerrero, Natalia Henao
    Pereira, Carolina H. Ricco
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2023, 84 (08)
  • [6] Lack of agreement between thermodilution and electrical velocimetry cardiac output measurements
    Heringlake, Matthias
    Handke, Ulrich
    Hanke, Thorsten
    Eberhardt, Frank
    Schumacher, Jan
    Gehring, Hartmut
    Heinze, Hermann
    INTENSIVE CARE MEDICINE, 2007, 33 (12) : 2168 - 2172
  • [7] Correlation, agreement and concordance of cardiac output estimated by transthoracic ultrasound and transesophageal Doppler with pulmonary artery thermodilution in anesthetized cats
    Pypendop, Bruno H.
    Rivas, Victor N.
    Bueno, Melissa Couto
    Chohan, Amandeep S.
    Barter, Linda S.
    Stern, Joshua A.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2024, 51 (06) : 641 - 649
  • [8] Lack of agreement between thermodilution and electrical velocimetry cardiac output measurements
    Matthias Heringlake
    Ulrich Handke
    Thorsten Hanke
    Frank Eberhardt
    Jan Schumacher
    Hartmut Gehring
    Hermann Heinze
    Intensive Care Medicine, 2007, 33 : 2168 - 2172
  • [9] Hemodilution with hespan results in progressive pulmonary vasoconstriction in conscious and isoflurane-anesthetized dogs
    Al-Bataineh, J
    DeFily, D
    Estafanous, F
    Murray, P
    ANESTHESIOLOGY, 1999, 91 (3A) : U520 - U520
  • [10] Lack of agreement between thermodilution and echocardiographic determination of cardiac output during normovolemia and acute hemorrhage in clinically healthy, anesthetized dogs
    Day, Thomas K.
    Boyle, Carolyn R.
    Holland, Merrilee
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2007, 17 (01) : 22 - 31