Amperometric sensor for gaseous H2O2 based on copper redox mediator incorporated electrolyte

被引:2
|
作者
Klun, Ursa [1 ]
Zorko, David [1 ]
Stojanov, Leon [2 ]
Mirceski, Valentin [2 ,3 ]
Jovanovski, Vasko [1 ]
机构
[1] Natl Inst Chem, Dept Mat Chem, Hajdrihova 19, Ljubljana 1000, Slovenia
[2] Ss Cyril & Methodius Univ, Inst Chem, Fac Nat Sci & Math, POB 162, Skopje 1000, North Macedonia
[3] Univ Lodz, Dept Inorgan & Analyt Chem, Tamka 12, PL-91403 Lodz, Poland
关键词
Electrochemical gas sensor; Hydrogen peroxide; Amperometry; Gel electrolyte; Copperion mediator; ELECTROCHEMICAL GAS SENSOR; HYDROGEN-PEROXIDE; POLY(ACRYLIC ACID); CURRENT TRENDS; KINETICS; COMPLEXES; NANOPARTICLES; STABILITY; CONSTANTS; WATER;
D O I
10.1016/j.snr.2023.100144
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The determination of gases and other volatile compounds using electrochemical gas sensors remains a challenge with respect to sensitivity and selectivity. Many real-life situations require fast, sensitive, and yet easy-to-operate sensors for gaseous hydrogen peroxide (H2O2) that can operate at room temperature. Herein, we present an H2O2 gas sensor comprising a polyacrylic acid and NaOH gel electrolyte that included Cu(II) ions acting as a redox mediator and commercially available screen-printed carbon electrodes. Aqueous polyacrylate gel electrolyte containing Cu(II) provided for sensing material that enabled the accumulation and stabilization of the gaseous analyte and via redox interaction with Cu(II) its fast and sensitive detection. The designed sensor exhibited good sensitivity in the low mg m- 3 range with a wide linear response in the examined concentration range of 10-100 mg m- 3 and a rapid detection after only 2 min accumulation under ambient conditions. Sensor's relatively simple setup and solid electroanalytical performance have strong application potential in emerging fields such as clinical diagnostics, explosive detection, environmental monitoring and occupational health and safety.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Graphite nanosheet-based composites for mediator-free H2O2 biosensor
    Chen, Xu
    Fu, Chenglin
    Yang, Wensheng
    ANALYST, 2009, 134 (10) : 2135 - 2140
  • [32] Aqueous-phase catalytic hydroxylation of phenol with H2O2 by using a copper incorporated apatite nanocatalyst
    Amedlous, Abdallah
    Amadine, Othmane
    Essamlali, Younes
    Daanoun, Karim
    Aadil, Mina
    Zahouily, Mohamed
    RSC ADVANCES, 2019, 9 (25) : 14132 - 14142
  • [33] Highly sensitive amperometric H2O2 biosensor based on hemoglobin modified TiO2 nanotubes
    Kafi, A. K. M.
    Wu, Guosheng
    Benvenuto, Paul
    Chen, Aicheng
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 662 (01) : 64 - 69
  • [34] A very thin overoxidized polypyrrole membrane as coating for fast time response and selective H2O2 amperometric sensor
    Debiemme-Chouvy, Catherine
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (11): : 2454 - 2457
  • [35] Amperometric H2O2 senor based on gold nanoparticles/poly (celestine blue) nanohybrid film
    Sangeetha, N. S.
    Narayanan, S. Sriman
    SN APPLIED SCIENCES, 2019, 1 (07):
  • [36] An Amperometric Biosensor of Determination H2O2 Based on Horseradish Peroxidase in Carbon Nanotubes/Ionic Liquid
    Wan, Jun
    Wang, Weina
    Yin, Guang
    Ma, Xiuju
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2012, 34 (06): : 1426 - 1432
  • [37] Synthesis and Characterization of a Multiporous SnO2 Nanofibers-Supported Au Nanoparticles-Based Amperometric Sensor for the Nonenzymatic Detection of H2O2
    Kader, Md. Ashraful
    Azmi, Nina Suhaity
    Kafi, A. K. M.
    Hossain, Md. Sanower
    Masri, Mohd Faizulnazrie Bin
    Ramli, Aizi Nor Mazila
    Tan, Ching Siang
    CHEMOSENSORS, 2023, 11 (02)
  • [38] Anoxia-reoxygenation alters H2O2 efflux and sensitivity of redox centers to copper in heart mitochondria
    Isei, Michael O.
    Chinnappareddy, Nirmala
    Stevens, Don
    Kamunde, Collins
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY C-TOXICOLOGY & PHARMACOLOGY, 2021, 248
  • [39] Regulation of the permeability of biomembranes to H2O2: Implications for redox compartmentalization
    Branco, MR
    Pedros, N
    Sousa-Lopes, A
    Marinho, HS
    Cyrne, L
    Antunes, F
    FREE RADICAL BIOLOGY AND MEDICINE, 2004, 37 : S60 - S60
  • [40] Spectrophotometric determination of H2O2 by redox reactions in the chitosan matrix
    Battle, L
    Young, S
    Ravi, N
    Bhatia, SC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U240 - U240