Toward IoT-Based Medical Edge Devices: PPG-Based Blood Pressure Estimation Application

被引:7
|
作者
Bernard, Denis [1 ]
Msigwa, Constantino [1 ]
Yun, Jaeseok [1 ,2 ]
机构
[1] Soonchunhyang Univ, Dept Future Convergence Technol, Asan 31538, South Korea
[2] Soonchunhyang Univ, Dept Internet Things, Asan 31538, South Korea
关键词
Biomedical monitoring; Estimation; Internet of Things; Feature extraction; Blood pressure; Standards; Monitoring; Bidirectional long short-term memory; blood pressure (BP); convolutional neural network (CNN); interworking proxy; medical edge; oneM2M; photoplethysmogram; PHOTOPLETHYSMOGRAM; SIGNAL; PLATFORM; LSTM;
D O I
10.1109/JIOT.2022.3222477
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The Internet of Things (IoT) now provide a considerable advantage in terms of intelligent devices. For example, sensor data of medical equipment could be used to extract meaningful insights to enable a range of tasks to be performed intelligently at the device location, such as blood pressure (BP) prediction several minutes ahead. In this article, we propose a computing device called Medical Edge, designed to convert conventional medical equipment into IoT-enabled devices. We developed an interworking proxy that allows Medical Edge to be interfaced with medical devices, such as patient monitors (e.g., GE CARESCAPE B650), to smoothly collect physiological data and upload them to an IoT server platform. We used a oneM2M standard-based server platform to provide access to these data in a standardized manner. To demonstrate a promising application of our proposed Medical Edges, we performed a study on BP estimation based on photoplethysmography (PPG) signal only. We propose a hybrid neural network architecture and apply it with a publicly available data set called multiparameter intelligent monitoring in intensive care II (MIMIC II). The model consists of five 1-D convolutional neural networks (CNNs), three Bi-directional long short-term memory networks, and four fully connected layers. The mean absolute error (MAE) and standard deviation (STD) of the proposed model were, respectively, 0.95 and 1.44 millimetres of mercury (mmHg) for diastolic BP (DBP), and 1.38 and 2.13 mmHg for systolic BP (SBP). The experimental results are in full compliance with the international standards of the Association for the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS).
引用
收藏
页码:5240 / 5255
页数:16
相关论文
共 50 条
  • [21] Q-PPG: Energy-Efficient PPG-Based Heart Rate Monitoring on Wearable Devices
    Burrello, Alessio
    Pagliari, Daniele Jahier
    Risso, Matteo
    Benatti, Simone
    Macii, Enrico
    Benini, Luca
    Poncino, Massimo
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2021, 15 (06) : 1196 - 1209
  • [22] PPG-Based Heart Rate Estimation Using Unsupervised Domain Adaptation
    Kim, Jihyun
    Lee, Minjung
    Cho, Hansam
    Kim, Seoung Bum
    [J]. ADVANCES AND TRENDS IN ARTIFICIAL INTELLIGENCE: THEORY AND APPLICATIONS, IEA-AIE 2024, 2024, 14748 : 291 - 296
  • [23] Robust PPG-Based Mental Workload Assessment System Using Wearable Devices
    Beh, Win-Ken
    Wu, Yi-Hsuan
    Wu, An-Yeu
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (05) : 2323 - 2333
  • [24] NAS-PPG: PPG-Based Heart Rate Estimation Using Neural Architecture Search
    Song, Seok Bin
    Nam, Jung Woo
    Kim, Jin Heon
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (13) : 14941 - 14949
  • [25] IoT-Based State Estimation for Microgrids
    Rana, Md M.
    Xiang, Wei
    Wang, Eric
    [J]. IEEE INTERNET OF THINGS JOURNAL, 2018, 5 (02): : 1345 - 1346
  • [26] IoT-Based Medical Control System
    Tamgno, James K.
    Diallo, Ndeye Rokhaya
    Lishou, Claude
    [J]. 2018 20TH INTERNATIONAL CONFERENCE ON ADVANCED COMMUNICATION TECHNOLOGY (ICACT), 2018, : 399 - 404
  • [27] PPG-Based Blood Pressure Monitoring by Pulse Wave Analysis: Calibration Parameters are Stable for Three Months
    Proenca, Martin
    Bonnier, Guillaume
    Ferrario, Damien
    Verjus, Christophe
    Lemay, Mathieu
    [J]. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 5560 - 5563
  • [28] The Role of IoT-Based Devices for the Better World
    Chaudhary, Ajay
    Peddoju, Sateesh K.
    [J]. INFORMATION AND COMMUNICATION TECHNOLOGY (ICICT 2016), 2018, 625 : 299 - 309
  • [29] Verifying Secure Authentication Protocol for Communication between IoT-based Medical Devices
    Theera-Umpon, Nipon
    Han, Kun-Hee
    Bae, Woo-Sik
    Lee, Sanghyuk
    Van Huy Pham
    [J]. JOURNAL OF UNIVERSAL COMPUTER SCIENCE, 2018, 24 (09) : 1258 - 1270
  • [30] A Medical IoT-Based Remote Monitoring System: Application on Diabetic Foot
    Fernando Moncada-Sanchez, Luis
    Antonio Salido-Ruiz, Ricardo
    Espinoza-Valdez, Aurora
    [J]. VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 1313 - 1319