Measurement of extracellular volume fraction using magnetic resonance-based conductivity tensor imaging

被引:2
|
作者
Choi, Bup Kyung [1 ]
Katoch, Nitish [1 ]
Park, Ji Ae [2 ]
Kim, Jin Woong [3 ,4 ]
Oh, Tong In [1 ]
Kim, Hyung Joong [1 ]
Woo, Eung Je [1 ]
机构
[1] Kyung Hee Univ, Dept Biomed Engn, Seoul, South Korea
[2] Korea Inst Radiol & Med Sci, Div Appl RI, Seoul, South Korea
[3] Chosun Univ Hosp, Dept Radiol, Gwangju, South Korea
[4] Chosun Univ, Coll Med, Gwangju, South Korea
基金
新加坡国家研究基金会;
关键词
electrical conductivity; extracellular volume fraction; conductivity tensor imaging; giant vesicle; magnetic resonance imaging; APPARENT DIFFUSION-COEFFICIENT; ELECTRICAL-CONDUCTIVITY; HUMAN BRAIN; CELLULARITY; TISSUE; MODEL;
D O I
10.3389/fphys.2023.1132911
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Conductivity tensor imaging (CTI) using MRI is an advanced method that can non-invasively measure the electrical properties of living tissues. The contrast of CTI is based on underlying hypothesis about the proportionality between the mobility and diffusivity of ions and water molecules inside tissues. The experimental validation of CTI in both in vitro and in vivo settings is required as a reliable tool to assess tissue conditions. The changes in extracellular space can be indicators for disease progression, such as fibrosis, edema, and cell swelling. In this study, we conducted a phantom imaging experiment to test the feasibility of CTI for measuring the extracellular volume fraction in biological tissue. To mimic tissue conditions with different extracellular volume fractions, four chambers of giant vesicle suspension (GVS) with different vesicle densities were included in the phantom. The reconstructed CTI images of the phantom were compared with the separately-measured conductivity spectra of the four chambers using an impedance analyzer. Moreover, the values of the estimated extracellular volume fraction in each chamber were compared with those measured by a spectrophotometer. As the vesicle density increased, we found that the extracellular volume fraction, extracellular diffusion coefficient, and low-frequency conductivity decreased, while the intracellular diffusion coefficient slightly increased. On the other hand, the high-frequency conductivity could not clearly distinguish the four chambers. The extracellular volume fraction measured by the spectrophotometer and CTI method in each chamber were quite comparable, i.e., (1.00, 0.98 +/- 0.01), (0.59, 0.63 +/- 0.02), (0.40, 0.40 +/- 0.05), and (0.16, 0.18 +/- 0.02). The prominent factor influencing the low-frequency conductivity at different GVS densities was the extracellular volume fraction. Further studies are needed to validate the CTI method as a tool to measure the extracellular volume fractions in living tissues with different intracellular and extracellular compartments.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Myocardial extravascular extracellular volume fraction measurement by gadolinium cardiovascular magnetic resonance in humans: slow infusion versus bolus
    Erik B Schelbert
    Stephen M Testa
    Christopher G Meier
    William J Ceyrolles
    Joshua E Levenson
    Alexander J Blair
    Peter Kellman
    Bobby L Jones
    Daniel R Ludwig
    David Schwartzman
    Sanjeev G Shroff
    Timothy C Wong
    Journal of Cardiovascular Magnetic Resonance, 13
  • [42] Myocardial extravascular extracellular volume fraction measurement by gadolinium cardiovascular magnetic resonance in humans: slow infusion versus bolus
    Schelbert, Erik B.
    Testa, Stephen M.
    Meier, Christopher G.
    Ceyrolles, William J.
    Levenson, Joshua E.
    Blair, Alexander J.
    Kellman, Peter
    Jones, Bobby L.
    Ludwig, Daniel R.
    Schwartzman, David
    Shroff, Sanjeev G.
    Wong, Timothy C.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
  • [43] Cardiovascular magnetic resonance measurement of myocardial extracellular volume in health and disease
    Sado, Daniel M.
    Flett, Andrew S.
    Banypersad, Sanjay M.
    White, Steven K.
    Maestrini, Viviana
    Quarta, Giovanni
    Lachmann, Robin H.
    Murphy, Elaine
    Mehta, Atul
    Hughes, Derralynn A.
    McKenna, William J.
    Taylor, Andrew M.
    Hausenloy, Derek J.
    Hawkins, Philip N.
    Elliott, Perry M.
    Moon, James C.
    HEART, 2012, 98 (19) : 1436 - 1441
  • [44] Utility of magnetic resonance imaging and nuclear magnetic resonance-based metabolomics for quantification of inflammatory lung injury
    Serkova, Natalie J.
    Van Rheen, Zachary
    Tobias, Meghan
    Pitzer, Joshua E.
    Wilkinson, J. Erby
    Stringer, Kathleen A.
    AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2008, 295 (01) : L152 - L161
  • [45] Fabrication of a spherical inclusion phantom for validation of magnetic resonance-based magnetic susceptibility imaging
    Kim, Jun-Ho
    Kim, Jung-Hyun
    Lee, So-Hee
    Park, Jinhyoung
    Lee, Seung-Kyun
    PLOS ONE, 2019, 14 (08):
  • [46] Increased skeletal muscle extracellular volume fraction in patients with Becker muscular dystrophy assessed by quantitative magnetic resonance imaging
    Marty, B.
    Baudin, P.
    Fromes, Y.
    Wahbi, K.
    Reyngoudt, H.
    NEUROMUSCULAR DISORDERS, 2022, 32 : S68 - S68
  • [47] Quantification of right ventricular extracellular volume in pulmonary hypertension using cardiac magnetic resonance imaging
    Habert, P.
    Capron, T.
    Hubert, S.
    Bentatou, Z.
    Bartoli, A.
    Tradi, F.
    Renard, S.
    Rapacchi, S.
    Guye, M.
    Bernard, M.
    Habib, G.
    Jacquier, A.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (05) : 311 - 320
  • [48] Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography - A comparison with magnetic resonance imaging
    Malm, S
    Frigstad, S
    Sagberg, E
    Larsson, H
    Skjaerpe, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (05) : 1030 - 1035
  • [49] Pancreas volume measurement in patients with Type 2 diabetes using magnetic resonance imaging-based planimetry
    Burute, Nishigandha
    Nisenbaum, Rosane
    Jenkins, David J.
    Mirrahimi, Arash
    Anthwal, Shalini
    Colak, Errol
    Kirpalani, Anish
    PANCREATOLOGY, 2014, 14 (04) : 268 - 274
  • [50] Volume measurement of horizontal extraocular muscles with magnetic resonance imaging
    Nishida, Y
    Aoki, Y
    Hayashi, O
    Murata, T
    Nishida, E
    Kani, K
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 1996, 40 (03) : 439 - 446