Measurement of extracellular volume fraction using magnetic resonance-based conductivity tensor imaging

被引:2
|
作者
Choi, Bup Kyung [1 ]
Katoch, Nitish [1 ]
Park, Ji Ae [2 ]
Kim, Jin Woong [3 ,4 ]
Oh, Tong In [1 ]
Kim, Hyung Joong [1 ]
Woo, Eung Je [1 ]
机构
[1] Kyung Hee Univ, Dept Biomed Engn, Seoul, South Korea
[2] Korea Inst Radiol & Med Sci, Div Appl RI, Seoul, South Korea
[3] Chosun Univ Hosp, Dept Radiol, Gwangju, South Korea
[4] Chosun Univ, Coll Med, Gwangju, South Korea
基金
新加坡国家研究基金会;
关键词
electrical conductivity; extracellular volume fraction; conductivity tensor imaging; giant vesicle; magnetic resonance imaging; APPARENT DIFFUSION-COEFFICIENT; ELECTRICAL-CONDUCTIVITY; HUMAN BRAIN; CELLULARITY; TISSUE; MODEL;
D O I
10.3389/fphys.2023.1132911
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Conductivity tensor imaging (CTI) using MRI is an advanced method that can non-invasively measure the electrical properties of living tissues. The contrast of CTI is based on underlying hypothesis about the proportionality between the mobility and diffusivity of ions and water molecules inside tissues. The experimental validation of CTI in both in vitro and in vivo settings is required as a reliable tool to assess tissue conditions. The changes in extracellular space can be indicators for disease progression, such as fibrosis, edema, and cell swelling. In this study, we conducted a phantom imaging experiment to test the feasibility of CTI for measuring the extracellular volume fraction in biological tissue. To mimic tissue conditions with different extracellular volume fractions, four chambers of giant vesicle suspension (GVS) with different vesicle densities were included in the phantom. The reconstructed CTI images of the phantom were compared with the separately-measured conductivity spectra of the four chambers using an impedance analyzer. Moreover, the values of the estimated extracellular volume fraction in each chamber were compared with those measured by a spectrophotometer. As the vesicle density increased, we found that the extracellular volume fraction, extracellular diffusion coefficient, and low-frequency conductivity decreased, while the intracellular diffusion coefficient slightly increased. On the other hand, the high-frequency conductivity could not clearly distinguish the four chambers. The extracellular volume fraction measured by the spectrophotometer and CTI method in each chamber were quite comparable, i.e., (1.00, 0.98 +/- 0.01), (0.59, 0.63 +/- 0.02), (0.40, 0.40 +/- 0.05), and (0.16, 0.18 +/- 0.02). The prominent factor influencing the low-frequency conductivity at different GVS densities was the extracellular volume fraction. Further studies are needed to validate the CTI method as a tool to measure the extracellular volume fractions in living tissues with different intracellular and extracellular compartments.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Analysis of reconstruction performance of magnetic resonance conductivity tensor imaging (MRCTI) using simulated measurements
    Degirmenci, Evren
    Eyuboglu, Behcet Murat
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2017, 25 (01) : 474 - 483
  • [22] Brain tissue conductivity reconstruction based on Dffusion Tensor Magnetic Resonance Imaging: A simulation study
    Yan, Dandan
    Zhang, Xiaotong
    Gao, Nuo
    Zhu, Shanan
    Mueller, Bryon
    Lim, Kelvin
    Liu, Zhongming
    He, Bin
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 325 - +
  • [23] Reply: Prediction of the Left Ventricular Functional Outcome by Myocardial Extracellular Volume Fraction Measured Using Magnetic Resonance Imaging; Methodological Issue
    Chen, Yinyin
    Zeng, Mengsu
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (08) : 1311 - 1312
  • [24] RE: Prediction of the Left Ventricular Functional Outcome by Myocardial Extracellular Volume Fraction Measured Using Magnetic Resonance Imaging: Methodological Issue
    Karimi, Shiva
    Pourmehdi, Mojtaba
    Naderi, Mehdi
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (06) : 1001 - 1002
  • [25] Tibial cartilage volume measurement in knee osteoarthritis using magnetic resonance imaging
    Vanichtantikul, Varalee
    Hongvilai, Sarit
    Numkarunarunrote, Numphung
    ASIAN BIOMEDICINE, 2015, 9 (01) : 41 - 47
  • [26] Magnetic resonance-based total liver volume and magnetic resonance-diffusion weighted imaging for staging liver fibrosis in mini-pigs
    Hang Li
    Tian-Wu Chen
    Xiao-Li Chen
    Xiao-Ming Zhang
    Zhen-Lin Li
    Nan-Lin Zeng
    Li Zhou
    Li-Ying Wang
    Hong-Jie Tang
    Chun-Ping Li
    Li Li
    Xian-Yong Xie
    World Journal of Gastroenterology, 2012, 18 (48) : 7225 - 7233
  • [27] Measurement of lateral ventricle volume of normal infant based on magnetic resonance imaging
    Lu Z.
    He J.
    Yu Y.
    Li Z.
    Li Z.
    Gong J.
    Chinese Neurosurgical Journal, 5 (1)
  • [28] Measurement of lateral ventricle volume of normal infant based on magnetic resonance imaging
    LuZheng
    HeJintao
    YuYaxiong
    LiZhicen
    LiZhi
    GongJian
    中华神经外科杂志(英文), 2019, (02) : 65 - 70
  • [29] Reproducibility of hepatic fat fraction measurement by magnetic resonance imaging
    Mashhood, Arian
    Railkar, Radha
    Yokoo, Takeshi
    Levin, Yakir
    Clark, Lisa
    Fox-Bosetti, Sabrina
    Middleton, Michael S.
    Riek, Jonathan
    Kauh, Eunkyung
    Dardzinski, Bernard J.
    Williams, Donald
    Sirlin, Claude
    Shire, Norah J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (06) : 1359 - 1370
  • [30] Magnetic resonance-based total liver volume and magnetic resonance-diffusion weighted imaging for staging liver fibrosis in mini-pigs
    Li, Hang
    Chen, Tian-Wu
    Chen, Xiao-Li
    Zhang, Xiao-Ming
    Li, Zhen-Lin
    Zeng, Nan-Lin
    Zhou, Li
    Wang, Li-Ying
    Tang, Hong-Jie
    Li, Chun-Ping
    Li, Li
    Xie, Xian-Yong
    WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (48) : 7225 - 7233