Measurement of extracellular volume fraction using magnetic resonance-based conductivity tensor imaging
被引:2
|作者:
Choi, Bup Kyung
[1
]
Katoch, Nitish
[1
]
Park, Ji Ae
[2
]
Kim, Jin Woong
[3
,4
]
Oh, Tong In
[1
]
Kim, Hyung Joong
[1
]
Woo, Eung Je
[1
]
机构:
[1] Kyung Hee Univ, Dept Biomed Engn, Seoul, South Korea
[2] Korea Inst Radiol & Med Sci, Div Appl RI, Seoul, South Korea
[3] Chosun Univ Hosp, Dept Radiol, Gwangju, South Korea
[4] Chosun Univ, Coll Med, Gwangju, South Korea
基金:
新加坡国家研究基金会;
关键词:
electrical conductivity;
extracellular volume fraction;
conductivity tensor imaging;
giant vesicle;
magnetic resonance imaging;
APPARENT DIFFUSION-COEFFICIENT;
ELECTRICAL-CONDUCTIVITY;
HUMAN BRAIN;
CELLULARITY;
TISSUE;
MODEL;
D O I:
10.3389/fphys.2023.1132911
中图分类号:
Q4 [生理学];
学科分类号:
071003 ;
摘要:
Conductivity tensor imaging (CTI) using MRI is an advanced method that can non-invasively measure the electrical properties of living tissues. The contrast of CTI is based on underlying hypothesis about the proportionality between the mobility and diffusivity of ions and water molecules inside tissues. The experimental validation of CTI in both in vitro and in vivo settings is required as a reliable tool to assess tissue conditions. The changes in extracellular space can be indicators for disease progression, such as fibrosis, edema, and cell swelling. In this study, we conducted a phantom imaging experiment to test the feasibility of CTI for measuring the extracellular volume fraction in biological tissue. To mimic tissue conditions with different extracellular volume fractions, four chambers of giant vesicle suspension (GVS) with different vesicle densities were included in the phantom. The reconstructed CTI images of the phantom were compared with the separately-measured conductivity spectra of the four chambers using an impedance analyzer. Moreover, the values of the estimated extracellular volume fraction in each chamber were compared with those measured by a spectrophotometer. As the vesicle density increased, we found that the extracellular volume fraction, extracellular diffusion coefficient, and low-frequency conductivity decreased, while the intracellular diffusion coefficient slightly increased. On the other hand, the high-frequency conductivity could not clearly distinguish the four chambers. The extracellular volume fraction measured by the spectrophotometer and CTI method in each chamber were quite comparable, i.e., (1.00, 0.98 +/- 0.01), (0.59, 0.63 +/- 0.02), (0.40, 0.40 +/- 0.05), and (0.16, 0.18 +/- 0.02). The prominent factor influencing the low-frequency conductivity at different GVS densities was the extracellular volume fraction. Further studies are needed to validate the CTI method as a tool to measure the extracellular volume fractions in living tissues with different intracellular and extracellular compartments.