Measurement of extracellular volume fraction using magnetic resonance-based conductivity tensor imaging

被引:2
|
作者
Choi, Bup Kyung [1 ]
Katoch, Nitish [1 ]
Park, Ji Ae [2 ]
Kim, Jin Woong [3 ,4 ]
Oh, Tong In [1 ]
Kim, Hyung Joong [1 ]
Woo, Eung Je [1 ]
机构
[1] Kyung Hee Univ, Dept Biomed Engn, Seoul, South Korea
[2] Korea Inst Radiol & Med Sci, Div Appl RI, Seoul, South Korea
[3] Chosun Univ Hosp, Dept Radiol, Gwangju, South Korea
[4] Chosun Univ, Coll Med, Gwangju, South Korea
基金
新加坡国家研究基金会;
关键词
electrical conductivity; extracellular volume fraction; conductivity tensor imaging; giant vesicle; magnetic resonance imaging; APPARENT DIFFUSION-COEFFICIENT; ELECTRICAL-CONDUCTIVITY; HUMAN BRAIN; CELLULARITY; TISSUE; MODEL;
D O I
10.3389/fphys.2023.1132911
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Conductivity tensor imaging (CTI) using MRI is an advanced method that can non-invasively measure the electrical properties of living tissues. The contrast of CTI is based on underlying hypothesis about the proportionality between the mobility and diffusivity of ions and water molecules inside tissues. The experimental validation of CTI in both in vitro and in vivo settings is required as a reliable tool to assess tissue conditions. The changes in extracellular space can be indicators for disease progression, such as fibrosis, edema, and cell swelling. In this study, we conducted a phantom imaging experiment to test the feasibility of CTI for measuring the extracellular volume fraction in biological tissue. To mimic tissue conditions with different extracellular volume fractions, four chambers of giant vesicle suspension (GVS) with different vesicle densities were included in the phantom. The reconstructed CTI images of the phantom were compared with the separately-measured conductivity spectra of the four chambers using an impedance analyzer. Moreover, the values of the estimated extracellular volume fraction in each chamber were compared with those measured by a spectrophotometer. As the vesicle density increased, we found that the extracellular volume fraction, extracellular diffusion coefficient, and low-frequency conductivity decreased, while the intracellular diffusion coefficient slightly increased. On the other hand, the high-frequency conductivity could not clearly distinguish the four chambers. The extracellular volume fraction measured by the spectrophotometer and CTI method in each chamber were quite comparable, i.e., (1.00, 0.98 +/- 0.01), (0.59, 0.63 +/- 0.02), (0.40, 0.40 +/- 0.05), and (0.16, 0.18 +/- 0.02). The prominent factor influencing the low-frequency conductivity at different GVS densities was the extracellular volume fraction. Further studies are needed to validate the CTI method as a tool to measure the extracellular volume fractions in living tissues with different intracellular and extracellular compartments.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Measurement of extracellular volume fraction by cardiac magnetic resonance imaging detects diffuse myocardial fibrosis in systemic sclerosis
    Daniel C Lee
    Roberto Sarnari
    Alejandro Aquino
    Maria M Izquierdo-Gomez
    Brandon Benefield
    Monique Hinchcliff
    John Varga
    Sofia Podlusky
    Maria Carr
    Aya Kino
    James Carr
    Edwin Wu
    Sanjiv Shah
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [2] Measurement of Extracellular Volume Fraction by Cardiac Magnetic Resonance Imaging Detects Diffuse Myocardial Fibrosis in Systemic Sclerosis
    Aquino, Alejandro
    Gomez, Maria M. Izquierdo
    Shah, Sanjiv J.
    Hinchcliff, Monique
    Varga, John
    Podlusky, Sofia
    Benefield, Brandon
    Carr, Maria L.
    Kino, Aya
    Carr, James C.
    Wu, Edwin
    Lee, Daniel C.
    CIRCULATION, 2011, 124 (21)
  • [3] Conductivity tensor imaging of the brain using diffusion-weighted magnetic resonance imaging
    Sekino, M
    Yamaguchi, K
    Iriguchi, N
    Ueno, S
    JOURNAL OF APPLIED PHYSICS, 2003, 93 (10) : 6730 - 6732
  • [4] Iterative sensitivity matrix-based magnetic resonance conductivity tensor imaging
    Degirmenci, Evren
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2019, 27 (01) : 24 - 36
  • [5] The relationship between cardiovascular magnetic resonance imaging measurement of extracellular volume fraction and clinical outcomes in adults with repaired tetralogy of Fallot
    Hanneman, Kate
    Crean, Andrew M.
    Wintersperger, Bernd J.
    Thavendiranathan, Paaladinesh
    Nguyen, Elsie T.
    Kayedpour, Camilla
    Wald, Rachel M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (07) : 777 - 784
  • [6] Automated Measurement of Native T1 and Extracellular Volume Fraction in Cardiac Magnetic Resonance Imaging Using a Commercially Available Deep Learning Algorithm
    Chang, Suyon
    Han, Kyunghwa
    Lee, Suji
    Yang, Young Joong
    Kim, Pan Ki
    Choi, Byoung Wook
    Suh, Young Joo
    KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (12) : 1251 - 1259
  • [7] A method for estimating intracellular sodium concentration and extracellular volume fraction in brain in vivo using sodium magnetic resonance imaging
    Madelin, Guillaume
    Kline, Richard
    Walvick, Ronn
    Regatte, Ravinder R.
    SCIENTIFIC REPORTS, 2014, 4
  • [8] A method for estimating intracellular sodium concentration and extracellular volume fraction in brain in vivo using sodium magnetic resonance imaging
    Guillaume Madelin
    Richard Kline
    Ronn Walvick
    Ravinder R. Regatte
    Scientific Reports, 4
  • [9] Measurement of the extracellular volume of human melanoma xenografts by contrast enhanced magnetic resonance imaging
    Bjornæs, I
    Halsor, EF
    Skretting, A
    Rofstad, EK
    MAGNETIC RESONANCE IMAGING, 2000, 18 (01) : 41 - 48
  • [10] Magnetic resonance imaging measurement of volume magnetic susceptibility using a boundary condition
    Wang, ZYJ
    Li, SC
    Haselgrove, JC
    JOURNAL OF MAGNETIC RESONANCE, 1999, 140 (02) : 477 - 481