Safety, biocompatibility, and potential functionality of a new accommodative intraocular lens: An experimental study in rabbits

被引:1
|
作者
Fernandez-Bueno, Ivan [1 ,2 ,6 ]
Olcina, Luis Ignacio [3 ]
Andres-Iglesias, Cristina [1 ]
Puertas-Neyra, Kevin [1 ]
Fernandez-Martinez, Itziar [1 ,4 ]
Usategui-Martin, Ricardo [1 ,2 ,5 ]
Maldonado-Lopez, Miguel Jose [1 ,2 ]
机构
[1] Univ Valladolid, Inst Univ Oftalmobiol Aplicada IOBA, Retina Grp, Valladolid 47011, Spain
[2] Natl Inst Hlth Carlos III, RICORS Inflamac & Inmunopatol Organos & Sistemas R, Madrid, Spain
[3] Consorcio Hosp Gen Univ Valencia, Valencia 46013, Spain
[4] Natl Inst Hlth Carlos III, CIBER BBN, Madrid, Spain
[5] Univ Valladolid, Dept Biol Celular Histol & Farmacol, Valladolid 47005, Spain
[6] Univ Valladolid UVa, Inst Univ Oftalmobiol Aplicada IOBA, Campus Miguel Delibes,Paseo Belen 17, Valladolid 47011, Spain
关键词
Presbyopia; Accommodative lens; Intraocular lens; Preclinical test; Biocompatibility; CAPSULAR BAG OPACIFICATION; LONG-TERM UVEAL; IN-VITRO; SILICONE; RESTORATION; STABILITY; BENEFITS; EYES;
D O I
10.1016/j.heliyon.2023.e19604
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aims to evaluate the safety, biocompatibility, and functionality of a new accommodative intraocular lens (IOL) (LUZ, patent PCT/ES2016/070,813) after implantation in rabbit eyes. LUZ (Study) and EyeCee & REG; plus a capsular ring (Control) were implanted in rabbits (n = 8 each) after phacoemulsification. Intraoperative follow-up, long-term clinical follow-up, and functional IOL studies were carried out periodically for up to 180 days. A macroscopic examination of the eyeballs to reveal abnormalities and determine the implant centering and a microscopic examination to semi-quantify cell and tissue response were performed. Statistical analysis of the collected data was finally achieved. During follow-up, no significant changes in the general condition nor the clinical evaluation were observed between both groups. However, Study IOL remained centered throughout the study and did not present severe complications as observed in the Control group. Functional studies did not reveal significant differences between both materials. Study showed better centering, fewer adhesions, and maintenance of an opening capsular bag compared to the Control. Local biological effects caused by Study implantation are minimal and comparable to the Control. Therefore, LUZ showed no clinical signs or histological response of adverse reaction to the implanted material, according to UNE-EN ISO 11979-5 and 10993-6. Functionality must be confirmed in another animal species with greater lens accommodation capacity than the rabbit. LUZ keeps the capsular bag open, favoring its centering and avoiding fibrosis and adherence to the bag; this allows potential accommodation of this IOL and theoretically enables the patient to focus dynamically.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] The study of biocompatibility on the Carbon, Titanium and Carbon-Nitrogen Surface Modified Intraocular Lens
    Yuan Zhaoxu
    Gu Han Qing
    Sun Hui Minl
    Yuan Jia Qin
    Xu Yan Shan(International Intraocular Implant Training Centre
    [J]. Chinese Journal of Biomedical Engineering, 1999, (03) : 13 - 15
  • [32] Assessing the Functionality and Biocompatibility of a Wireless Contact Lens Sensor for 24 hour-intraocular Pressure Monitoring in Volunteers: Preliminary Results
    De Smedt, S. K., Sr.
    Mermoud, A.
    Roy, S.
    Schnyder, C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [33] Experimental study on cyclosporine A drug delivery system in prevention of posterior capsule opacification after intraocular lens implantation in rabbits
    裴澄
    孙乃学
    [J]. Journal of Pharmaceutical Analysis, 2008, (04) : 262 - 266
  • [34] An Evaluation of Biocompatibility of Indigenously Produced Pure Titanium: An Experimental Study in Rabbits
    Chittaranjan, Bhogisetty
    Murthy, Bhamidipati Sreerama
    Ravindranath, Turaga
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (05) : 575 - 580
  • [35] Experimental study of the effect of heat on intraocular lens PMMA haptics
    Ifantides, Cristos
    De Tora, Mari Johnson
    Shandas, Robin
    Wagner, Jennifer
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [36] Hydrophobic acrylic versus heparin surface-modified polymethylmethacrylate intraocular lens: a biocompatibility study
    Tognetto, D
    Toto, L
    Minutola, D
    Ballone, E
    di Nicola, M
    Di Mascio, R
    Ravalico, G
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2003, 241 (08) : 625 - 630
  • [37] Hydrophobic acrylic versus heparin surface-modified polymethylmethacrylate intraocular lens: a biocompatibility study
    Daniele Tognetto
    Lisa Toto
    Daniela Minutola
    Enzo Ballone
    Marta di Nicola
    Rocco Di Mascio
    Giuseppe Ravalico
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2003, 241 : 625 - 630
  • [38] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206
  • [39] RADIOIODINE CONTENT OF AQUEOUS, VITREOUS, AND LENS - AN EXPERIMENTAL STUDY IN RABBITS
    SHAPIRO, I
    GURNEY, CW
    SOLARI, AJ
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1957, 57 (03) : 430 - 434
  • [40] Extended depth of focus intraocular lens versus a new monofocal intraocular lens: A prospective comparative and interventional study
    Sihmar, Yogika
    Singh, Basant K.
    Singh, Vinod K.
    Kumar, Santosh
    Chaudhary, Aparajita
    Saini, Sanchita
    [J]. SAUDI JOURNAL OF OPHTHALMOLOGY, 2023, 37 (04) : 331 - 336