Hydrophobic acrylic versus heparin surface-modified polymethylmethacrylate intraocular lens: a biocompatibility study

被引:19
|
作者
Tognetto, D
Toto, L
Minutola, D
Ballone, E
di Nicola, M
Di Mascio, R
Ravalico, G
机构
[1] Univ Trieste, Osped Maggiore, Eye Clin, I-34129 Trieste, Italy
[2] Univ Chieti, Dept Med & Aging, Chieti, Italy
关键词
D O I
10.1007/s00417-003-0711-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background. The implant of intraocular lenses (IOLs) following cataract surgery induces a foreign-body reaction to the IOL and a response on the part of the lens epithelial cells (LECs). The purpose of this study was to compare these aspects after the implantation of two different IOL materials. Methods. Thirty-six cataract patients were randomised to receive two different foldable lens: an acrylic hydrophobic IOL (Acrysof MA30BA) and a heparin surface-modified (HSM) polymethylmethacrylate IOL (Pharmacia & Upjohn 809C) after phacoemulsification. Slit-lamp biomicroscopy with specular technique was used to assess the inflammatory cell adhesion on the anterior IOL surface, anterior capsule opacification (ACO) and membrane growth from the rhexis edge at 7, 30, 90, 180 and 360 days after surgery. Results. The 809C group showed a higher percentage of patients with slight inflammatory cell adhesion on the anterior cell surface and a higher small cellular density during the whole follow-up period. The epithelioid cell response was greater in the 809C group than the Acrysof group but the difference between the two groups was not statistically significant. The ACO increased during the follow-up in both groups but was significantly higher in the 809C group. Conclusion. Acrysof lenses are more biocompatible than HSM IOLs, showing a lower grade of inflammatory cell adhesion and ACO. The implantation of these lenses may be particularly indicated in patients with pathologies predisposing to blood-aqueous barrier damage.
引用
收藏
页码:625 / 630
页数:6
相关论文
共 50 条
  • [1] Hydrophobic acrylic versus heparin surface-modified polymethylmethacrylate intraocular lens: a biocompatibility study
    Daniele Tognetto
    Lisa Toto
    Daniela Minutola
    Enzo Ballone
    Marta di Nicola
    Rocco Di Mascio
    Giuseppe Ravalico
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2003, 241 : 625 - 630
  • [2] Comparison of clinical results between heparin surface modified hydrophilic acrylic and hydrophobic acrylic intraocular lens
    Kang, S.
    Kim, M. -J.
    Park, S. -H.
    Joo, C. -K.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (03) : 377 - 383
  • [3] BIOCOMPATIBILITY OF SURFACE-MODIFIED INTRAOCULAR LENSES
    UMEZAWA, S
    SHIMIZU, K
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (03): : 371 - 374
  • [4] Uveal and capsular biocompatibility of a new hydrophobic acrylic microincision intraocular lens
    Balendiran, Vaishnavi
    Werner, Liliana
    Ellis, Nathan
    Shumway, Caleb
    Jiang, Bill
    Kamae, Kai
    Mamalis, Nick
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (03): : 459 - 464
  • [5] Comparison of posterior capsular opacification in heparin-surface-modified hydrophilic acrylic and hydrophobic acrylic intraocular lenses
    Kang, Seungbum
    Choi, Jin A.
    Joo, Choun-Ki
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (03) : 204 - 208
  • [6] Silicone Oil Adhesion to Hydrophobic Acrylic Intraocular Lenses: A Comparative Laboratory Study of a New versus an Established Hydrophobic Acrylic Intraocular Lens Material
    Auffarth, Gerd U.
    Fang, Hui
    Wang, Qiang
    Hengerer, Fritz
    Khoramnia, Ramin
    Son, Hyeck-Soo
    Schickhardt, Sonja
    [J]. JOURNAL OF OPHTHALMOLOGY, 2021, 2021
  • [7] Foldable acrylic versus rigid polymethylmethacrylate intraocular lens in combined phacoemulsification and trabeculectomy
    Alzafiri, Y
    Harasymowycz, P
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2004, 39 (06): : 609 - 613
  • [8] Surface deposits mimicking calcification on a hydrophobic acrylic intraocular lens
    Werner, Liliana
    Wallace, J. Kenneth
    Balendiran, Vaishnavi
    Shumway, Caleb
    Ellis, Nathan
    Mamalis, Nick
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (07): : 1036 - 1039
  • [9] A retrospective analysis of heparin-surface-modified intraocular lenses versus regular polymethylmethacrylate intraocular lenses in patients with uveitis
    Lardenoye, CWTA
    VanDerLeLij, A
    Berendschot, TTJM
    Rothova, A
    [J]. DOCUMENTA OPHTHALMOLOGICA, 1996, 92 (01) : 41 - 50
  • [10] Heparin surface-modified poly(methylmethacrylate) and foldable hydrophobic acrylic intraocular lenses in cataract patients with acquired immune deficiency syndrome and CMV-retinitis
    Krieglsteiner, S
    Gümbel, HOC
    Kohnen, T
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2004, 221 (01) : 40 - 46