Assessment of ultrasound shear wave elastography: An animal ex-vivo study

被引:1
|
作者
Wang, Xiuming [1 ,2 ]
Zhu, Jiaan [1 ]
Liu, Yiqun [1 ]
Li, Wenxue [1 ]
Chen, Si [1 ]
Zhang, Huabin [2 ]
机构
[1] Peking Univ Peoples Hosp, Dept Ultrasound, 11 Xizhimen South St, Beijing 100044, Peoples R China
[2] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Dept Ultrasound, Beijing, Peoples R China
来源
关键词
lesion size; rectangular sampling box; shear wave elastography; WFUMB GUIDELINES; CLINICAL-USE; SKELETAL-MUSCLE; RECOMMENDATIONS; ELASTICITY; REGION;
D O I
10.1002/acm2.13924
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo explore the influence of the surrounding environment of the target tissue, lesion size, and rectangular sampling box size on shear wave speed (SWS). MethodsThe tendon SWS was acquired ex-vivo. Then the tendons were dissected and buried in the couplant (gel) and evaluated by two-dimensional shear wave elastography (2D-SWE). Finally, the tendons were placed in the isolated muscles to simulate the intramuscular lesions, and their elasticity was tested under two rectangular sampling box conditions. The isolated complete liver SWS was acquired. Similarly, the large and small pieces of livers were cut out, placed in the muscles, and assessed by SWE under two rectangular sampling box conditions. The SWS acquired under different conditions was compared. Variability was evaluated using the coefficient of variation (CV). The intraclass correlation coefficient (ICC) was used to evaluate repeatability. ResultsThe SWS of the tendons ex-vivo, buried in the couplant and placed in the isolated muscles showed significant differences (p < 0.001). The ex-vivo condition produced the highest SWS and CV values. There were significant differences in SWS of livers with different sizes placed in muscles (p < 0.001). The highest SWS value was associated with small pieces of livers. No significant difference was found in SWS acquired under different rectangular box sizes (p > 0.05). ConclusionsUnder the present study conditions, the surrounding environment of the target tissue makes a big difference to lesion SWS values. The lesion size will affect the assessment of its inherent elasticity. The size of the sampling frame has no significant effect on the tissue SWS.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] In vivo assessment of the levator ani muscles using shear wave elastography: a feasibility study in women
    Bertrand Gachon
    Antoine Nordez
    Fabrice Pierre
    Laetitia Fradet
    Xavier Fritel
    David Desseauve
    International Urogynecology Journal, 2019, 30 : 1179 - 1186
  • [42] A finite element model to study the effect of tissue anisotropy on ex vivo arterial shear wave elastography measurements
    Shcherbakova, D. A.
    Debusschere, N.
    Caenen, A.
    Iannaccone, F.
    Pernot, M.
    Swillens, A.
    Segers, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (13): : 5245 - 5275
  • [43] Ultrasound and magnetic resonance imaging for the detection of blood: An ex-vivo study
    Regi, Soumya Susan
    Livingstone, Roshan S.
    Kandagaddala, Madhavi
    Poonnoose, Pradeep
    Gibikote, Sridhar
    Keshava, Shyamkumar N.
    Srivastava, Alok
    HAEMOPHILIA, 2021, 27 (03) : 488 - 493
  • [44] Standardization of endoscopic ultrasound shear wave elastography
    Iglesias-Garcia, Julio
    Dominguez-Munoz, J. Enrique
    CLINICAL ENDOSCOPY, 2023, 56 (02) : 185 - 187
  • [45] Shear shock waves observed in the ex-vivo brain
    Espindola, David
    Pinton, Gianmarco
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [46] Wearable bioadhesive ultrasound shear wave elastography
    Liu, Hsiao-Chuan
    Zeng, Yushun
    Gong, Chen
    Chen, Xiaoyu
    Kijanka, Piotr
    Zhang, Junhang
    Genyk, Yuri
    Tchelepi, Hisham
    Wang, Chonghe
    Zhou, Qifa
    Zhao, Xuanhe
    SCIENCE ADVANCES, 2024, 10 (06)
  • [47] Ultrasound shear wave elastography in assessment of skeletal muscle stiffness in senior volunteers
    Phan, Andrew
    Lee, Juhyun
    Gao, Jing
    CLINICAL IMAGING, 2019, 58 : 22 - 26
  • [48] Ultrafast Quantitative Ultrasound and Shear Wave Elastography Imaging of In Vivo Duck Fatty Livers
    Gesnik, Marc
    Bhatt, Manish
    Roy-Cardinal, Marie-Helene
    Destrempes, Francois
    Chayer, Boris
    Allard, Louise
    Tang, An
    Cloutier, Guy
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1823 - 1826
  • [49] Comparison of liver stiffness assessment by transient elastography and shear wave elastography using six ultrasound devices
    Iijima, Hiroko
    Tada, Toshifumi
    Kumada, Takashi
    Kobayashi, Natsuko
    Yoshida, Masahiro
    Aoki, Tomoko
    Nishimura, Takashi
    Nakano, Chikage
    Ishii, Akio
    Takashima, Tomoyuki
    Sakai, Yoshiyuki
    Aizawa, Nobuhiro
    Nishikawa, Hiroki
    Ikeda, Naoto
    Iwata, Yoshinori
    Enomoto, Hirayuki
    Ide, Yoshi-Hiro
    Hirota, Seiichi
    Fujimoto, Jiro
    Nishiguchi, Shuhei
    HEPATOLOGY RESEARCH, 2019, 49 (06) : 676 - 686
  • [50] An Experimental Phantom Study on the Effect of Calcifications on Ultrasound Shear Wave Elastography
    Gregory, Adriana
    Bayat, Mahdi
    Denis, Max
    Mehrmohammadi, Mohammad
    Fatemi, Mostafa
    Alizad, Azra
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 3843 - 3846