Determination of Ciprofloxacin by Flow Injection Analysis Based on Chemiluminescence System

被引:0
|
作者
张卓勇 [1 ]
李夏 [1 ]
王小丽 [2 ]
陈世稆 [2 ]
宋保华 [1 ]
赵慧春 [2 ]
机构
[1] Department of Chemistry, Capital Normal University, Beijing 100037, China
[2] Department of Chemistry, Beijing Normal University, Beijing 100875, China
关键词
ciprofloxacin; chemiluminescence; terbium; flow injection; KMnO4; Na2S2O4; rare earths;
D O I
暂无
中图分类号
O657.3 [光化学分析法(光谱分析法)];
学科分类号
070302 ; 081704 ;
摘要
A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb 3+-CPLX chemiluminescence (CL) system. The effects of some critical experimental conditions were discussed and the optimization of working conditions was investigated. The linear dynamic range is 3.00×10 -8~9.00×10 -7 mol·L -1 and the detection limit for CPLX is 4.40×10 -9 mol·L -1. This method was applied to the determination of CPLX in tablet, urine, and serum samples and the recoveries of real sample analyses were in the range from 110±4 to 104±4.
引用
收藏
页码:285 / 288
页数:4
相关论文
共 50 条
  • [31] Flow injection chemiluminescence determination of hydrazine
    Safavi, A
    Baezzat, MR
    [J]. ANALYTICA CHIMICA ACTA, 1998, 358 (02) : 121 - 125
  • [32] Flow injection chemiluminescence determination of medazepam
    Sultan, SM
    Almuaibed, AM
    Townshend, A
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (01): : 167 - 169
  • [33] Flow injection chemiluminescence determination of tetracyclines
    Li, Z
    Feng, ML
    Lu, JR
    Gong, ZL
    Jiang, HL
    [J]. ANALYTICAL LETTERS, 1997, 30 (04) : 797 - 807
  • [34] Determination of diquat by flow injection–chemiluminescence
    J. L. López-Paz
    M. Catalá-Icardo
    B. Antón-Garrido
    [J]. Analytical and Bioanalytical Chemistry, 2009, 394 : 1073 - 1079
  • [35] DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION
    ABBOTT, RW
    TOWNSHEND, A
    GILL, R
    [J]. ANALYST, 1986, 111 (06) : 635 - 640
  • [36] Determination of pipernidic acid by flow injection analysis with chemiluminescence detection
    Li, LQ
    Wu, YY
    Feng, ML
    Lü, JR
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (02) : 169 - 171
  • [37] Determination of phenol in water by flow-injection chemiluminescence analysis
    Gong, ZJ
    Huang, YM
    Zhang, ZJ
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (09) : 1123 - 1125
  • [38] Chemiluminescence determination of thioridazine hydrochloride by flow-injection analysis
    Kojlo, A
    Michalowski, J
    Wolyniec, E
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (01) : 85 - 91
  • [39] Ultrasensitive Determination of Cadmium in Rice by Flow Injection Chemiluminescence Analysis
    Wang, Jiajia
    Song, Zhenghua
    [J]. FOOD ANALYTICAL METHODS, 2014, 7 (08) : 1671 - 1676
  • [40] CHEMILUMINESCENCE DETERMINATION OF BUPRENORPHINE HYDROCHLORIDE BY FLOW-INJECTION ANALYSIS
    ALWARTHAN, AA