A New Magnetic Sealless Coupling Axial Flow Blood Pump

被引:0
|
作者
LIN Chang-yan
机构
关键词
magnetic sealless coupling axial flow pump; dynamics output; damage to blood; sealing; heating;
D O I
暂无
中图分类号
R318.6 [仪器、设备];
学科分类号
0831 ;
摘要
For rotating blood pump, the sealing problem is a very important one to solve. In this paper, it was introduced that we designed and made a small axial flow pump, applying the magnetic coupling method. The pump consisted of two pump housings, a brushless DC motor, an impeller with five wanes, a pair of magnetic discs, a spacer, an inlet and an outlet areas , bearings, a support frame, and etc. The pump is made of titanium and is 125 mm length, 147 ml volume, total 380g of weight. Performances of outputting, sealing, heat creating and damage to blood by the pump were investigated in vitro experiment. Results showed for external experiment that: (1)The pressure created by the pump was 90 mmHg, the flow rates were 1.2 L/min, 4 L/min, 5.9 L/min and 7.8 L/min correspondingly to 5000 rpm, 6000 rpm, 7000 rpm and 8000rpm rotation speeds. The hydrodynamic performance of the axial flow blood pump was enough to meet a patient need when the blood pump was used as a left ventricular assistant device. (2)The hemolysis test was studied by the normalized index of hemolysis(NIH). The NIH result of the axial flow pump was 0.08 g/100 L. (3)The outside temperature of the pump didnt change obviously in 120 hours of rotation, and the sealing function was very well.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 50 条
  • [21] In vitro performance of a centrifugal, a mixed flow, and an axial flow blood pump
    Medical Informatics, Miyazaki Medical College Hospital, Miyazaki, Japan
    不详
    不详
    不详
    [J]. Artif. Organs, 5 (366-370):
  • [22] Development of miniaturized mass flow meter for an axial flow blood pump
    Kosaka, Ryo
    Maruyama, Osamu
    Nishida, Masahiro
    Yamane, Takashi
    [J]. ARTIFICIAL ORGANS, 2007, 31 (05) : 412 - 419
  • [23] In vitro performance of a centrifugal, a mixed flow, and an axial flow blood pump
    Araki, K
    Anai, H
    Oshikawa, M
    Nakamura, K
    Onitsuka, T
    [J]. ARTIFICIAL ORGANS, 1998, 22 (05) : 366 - 370
  • [24] Axial type self-bearing motor for axial flow blood pump
    Okada, Y
    Masuzawa, T
    Matsuda, KI
    Ohmori, K
    Yamane, T
    Konishi, Y
    Fukahori, S
    Ueno, S
    Kim, SJ
    [J]. ARTIFICIAL ORGANS, 2003, 27 (10) : 887 - 891
  • [25] Relationship between pump speed design and hemolysis in an axial flow blood pump
    Anai, H
    Wakisaka, Y
    Nakatani, T
    Taenaka, Y
    Takano, H
    Hadama, T
    [J]. ARTIFICIAL ORGANS, 1996, 20 (06) : 564 - 567
  • [26] Relationship between pump speed design and hemolysis in an axial flow blood pump
    Texas Heart Institute, Houston, TX, United States
    不详
    不详
    不详
    [J]. ARTIF. ORGANS, 5 (564-567):
  • [27] Effect of Conical Spiral Flow Channel and Impeller Parameters on Flow Field and Hemolysis Performance of an Axial Magnetic Blood Pump
    Yang, Wei-Bo
    Zhou, Jian
    Xiao, Wei-Hu
    Peng, Si-Jie
    Hu, Ye-Fa
    Li, Ming
    Wu, Hua-Chun
    [J]. PROCESSES, 2022, 10 (05)
  • [28] Numerical investigation on flow field and biocompatibility of an axial blood pump
    Zhu, Xianran
    Zhang, Mingyuan
    Liu, Haonan
    Zhang, Genguang
    [J]. Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2006, 40 (11): : 1290 - 1294
  • [29] Numerical Simulation Investigation on Flow Field of Axial Blood Pump
    Zhang, Lu
    Jia, Yuemei
    Zhang, Wei
    Wang, Yuxuan
    Zhao, Qiuxia
    [J]. ADVANCES IN COMPUTER SCIENCE AND ENGINEERING, 2012, 141 : 223 - +
  • [30] Discrete-continuous optimisation of an axial flow blood pump
    Tesch, K.
    Kaczorowska-Ditrich, K.
    [J]. XXIII FLUID MECHANICS CONFERENCE (KKMP 2018), 2018, 1101