Wearable wireless real-time cerebral oximeter for measuring regional cerebral oxygen saturation

被引:0
|
作者
Juanning SI [1 ,2 ]
Xin ZHANG [3 ,4 ,5 ]
Meng LI [1 ,2 ]
Jian YU [3 ,4 ,5 ]
Zhiyong ZHANG [3 ,4 ,5 ]
Qing HE [1 ,2 ]
Shaohua CHEN [1 ,2 ]
Lianqing ZHU [1 ,2 ]
Tianzi JIANG [3 ,4 ,5 ,6 ,7 ,8 ]
机构
[1] School of Instrumentation Science and Opto-electronics Engineering,Beijing Information Science and Technology University
[2] Beijing Key Laboratory for Optoelectronic Measurement Technology,Beijing Information Science and Technology University
[3] Brainnetome Center,Institute of Automation,Chinese Academy of Sciences
[4] National Laboratory of Pattern Recognition,Institute of Automation,Chinese Academy of Sciences
[5] Research and Development Department,Casibrain Technology Limited Company
[6] Key Laboratory for NeuroInformation of the Ministry of Education,School of Life Science and Technology,University of Electronic Science and Technology of China
[7] Chinese Academy of Sciences Center for Excellence in Brain Science,Institute of Automation,Chinese Academy of Sciences
[8] Queensland Brain Institute,University of Queensland
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
R318.6 [仪器、设备]; TP368.1 [微处理机]; TN92 [无线通信];
学科分类号
080402 ; 080904 ; 0810 ; 081001 ;
摘要
Monitoring regional cerebral oxygen saturation throughout the perioperative clinical process is important for successful patient outcomes. Cerebral oximeters based on near-infrared spectroscopy(NIRS)have already been used for monitoring brain oxygenation and hemodynamics to avoid intraoperative ischemic stroke and reduce postoperative cognitive dysfunction. The current devices are all designed to be used as a bedside monitor, limiting their use to situations that center around a hospital bed. There is a current lack of wearable, miniaturized, wireless equipment that can extend brain oxygenation monitoring to motion tasks or tight spaces. We design a head-mounted wearable wireless oxygen saturation monitoring on head(WORTH)band based on NIRS for monitoring regional cerebral oxygen saturation. The band is embedded with a highly integrated central block, which comprises an optical module, a microprocessor unit, a wireless communication module, and a power management module. The performance of the WORTH band is evaluated by a controlled hypoxia experiment and a squat-to-stand experiment. The results confirm that the WORTH band can record cerebral oxygen saturation with an accuracy comparable to that of a clinical monitor and demonstrate that it is also effective during motion tasks.
引用
收藏
页码:123 / 132
页数:10
相关论文
共 50 条
  • [41] Cerebral regional oxygen saturation monitoring in pediatric malfunctioning shunt patients
    Abramo, Thomas J.
    Zhou, Chuan
    Estrada, Cristina
    Drayna, Patrick C.
    Locklair, Matthew R.
    Miller, Renee
    Pearson, Matthew
    Tulipan, Noel
    Arnold, Donald H.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (02): : 365 - 374
  • [42] Skin pigmentation interferes with the clinical measurement of regional cerebral oxygen saturation
    Sun, X.
    Ellis, J.
    Corso, P. J.
    Hall, P. C.
    Chen, F.
    Lindsay, J.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (02) : 276 - 280
  • [43] Usefulness of regional cerebral oxygen saturation monitoring in balloon test occlusion
    Niizuma, Kuniyasu
    Kamii, Hideyuki
    Matsumoto, Yasushi
    Kondoh, Ryushi
    Shimizu, Hiroaki
    Tominaga, Teiji
    NEUROLOGICAL SURGERY, 2006, 34 (07): : 695 - 702
  • [44] The Change in Regional Cerebral Oxygen Saturation after Stellate Ganglion Block
    Park, Hyeon Min
    Kim, Tae Wan
    Choi, Hong Gyu
    Yoon, Kyung Bong
    Yoon, Duck Mi
    KOREAN JOURNAL OF PAIN, 2010, 23 (02): : 142 - 146
  • [45] Evaluation of a wireless pulse oximeter for measuring the arterial oxygen saturation and pulse frequency in Holstein Friesian calves
    Kanz, P.
    Iwersen, M.
    Krieger, S.
    Drillich, M.
    REPRODUCTION IN DOMESTIC ANIMALS, 2018, 53 : 20 - 20
  • [46] Cerebral haemorrhage in preterm neonates: does cerebral regional oxygen saturation during the immediate transition matter?
    Baik, Nariae
    Urlesberger, Berndt
    Schwaberger, Bernhard
    Schmoelzer, Georg M.
    Avian, Alexander
    Pichler, Gerhard
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2015, 100 (05): : F422 - F427
  • [47] USE OF TRANSCRANIAL CEREBRAL OXIMETRY TO MONITOR REGIONAL CEREBRAL OXYGEN-SATURATION DURING NEUROENDOVASCULAR PROCEDURES
    HERNANDEZAVILA, G
    DUJOVNY, M
    SLAVIN, KV
    LUER, MS
    NIJENSOHN, E
    GEREMIA, G
    AUSMAN, JI
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (08) : 1618 - 1625
  • [48] Over-estimation of cerebral oxygen saturation by commercial oximeter during deep hypothermic circulatory arrest
    Lynch, J. M.
    Ko, T.
    Mavroudis, C. D.
    Mensah-Brown, K.
    Busch, D. R.
    Nicolson, S. C.
    Gaynor, J. W.
    Yodh, A. G.
    Licht, D. J.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 183 - 184
  • [49] REAL-TIME ULTRASONOGRAPHIC DIAGNOSIS OF CEREBRAL DEATH
    FRANK, LM
    EARLEY, LC
    ANNALS OF NEUROLOGY, 1981, 10 (03) : 304 - 304
  • [50] Detection of cerebral arterial gas embolism using regional cerebral oxygen saturation, quantitative electroencephalography, and brain oxygen tension in the swine
    Weenink, R. P.
    Hollmann, M. W.
    Stevens, M. F.
    Kager, J.
    van Gulik, T. M.
    van Hulst, R. A.