Wearable wireless real-time cerebral oximeter for measuring regional cerebral oxygen saturation

被引:0
|
作者
Juanning SI [1 ,2 ]
Xin ZHANG [3 ,4 ,5 ]
Meng LI [1 ,2 ]
Jian YU [3 ,4 ,5 ]
Zhiyong ZHANG [3 ,4 ,5 ]
Qing HE [1 ,2 ]
Shaohua CHEN [1 ,2 ]
Lianqing ZHU [1 ,2 ]
Tianzi JIANG [3 ,4 ,5 ,6 ,7 ,8 ]
机构
[1] School of Instrumentation Science and Opto-electronics Engineering,Beijing Information Science and Technology University
[2] Beijing Key Laboratory for Optoelectronic Measurement Technology,Beijing Information Science and Technology University
[3] Brainnetome Center,Institute of Automation,Chinese Academy of Sciences
[4] National Laboratory of Pattern Recognition,Institute of Automation,Chinese Academy of Sciences
[5] Research and Development Department,Casibrain Technology Limited Company
[6] Key Laboratory for NeuroInformation of the Ministry of Education,School of Life Science and Technology,University of Electronic Science and Technology of China
[7] Chinese Academy of Sciences Center for Excellence in Brain Science,Institute of Automation,Chinese Academy of Sciences
[8] Queensland Brain Institute,University of Queensland
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
R318.6 [仪器、设备]; TP368.1 [微处理机]; TN92 [无线通信];
学科分类号
080402 ; 080904 ; 0810 ; 081001 ;
摘要
Monitoring regional cerebral oxygen saturation throughout the perioperative clinical process is important for successful patient outcomes. Cerebral oximeters based on near-infrared spectroscopy(NIRS)have already been used for monitoring brain oxygenation and hemodynamics to avoid intraoperative ischemic stroke and reduce postoperative cognitive dysfunction. The current devices are all designed to be used as a bedside monitor, limiting their use to situations that center around a hospital bed. There is a current lack of wearable, miniaturized, wireless equipment that can extend brain oxygenation monitoring to motion tasks or tight spaces. We design a head-mounted wearable wireless oxygen saturation monitoring on head(WORTH)band based on NIRS for monitoring regional cerebral oxygen saturation. The band is embedded with a highly integrated central block, which comprises an optical module, a microprocessor unit, a wireless communication module, and a power management module. The performance of the WORTH band is evaluated by a controlled hypoxia experiment and a squat-to-stand experiment. The results confirm that the WORTH band can record cerebral oxygen saturation with an accuracy comparable to that of a clinical monitor and demonstrate that it is also effective during motion tasks.
引用
收藏
页码:123 / 132
页数:10
相关论文
共 50 条
  • [21] Regional cerebral oxygen saturation monitoring during cardiac arrest
    Gwinnutt, Carl
    RESUSCITATION, 2014, 85 (09) : E129 - E129
  • [22] Cerebral Autoregulation Real-Time Monitoring
    Tsalach, Adi
    Ratner, Eliahu
    Lokshin, Stas
    Silman, Zmira
    Breskin, Ilan
    Budin, Nahum
    Kamar, Moshe
    PLOS ONE, 2016, 11 (08):
  • [23] Uninterrupted real-time cerebral stress level monitoring using wearable biosensors: A review
    Mishra, Anuja
    Agrawal, Mukti
    Ali, Aaliya
    Garg, Prakrati
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2023, 70 (06) : 1895 - 1914
  • [24] Cerebral Oxygenation during Laparoscopic Surgery: Jugular Bulb versus Regional Cerebral Oxygen Saturation
    Choi, Seung Ho
    Kim, Soo Hwan
    Lee, Sung Jin
    Soh, Sa Rah
    Oh, Young Jun
    YONSEI MEDICAL JOURNAL, 2013, 54 (01) : 225 - 230
  • [25] Impact of Extracranial Contamination on Regional Cerebral Oxygen Saturation A Comparison of Three Cerebral Oximetty Technologies
    Davie, Sophie N.
    Grocott, Hilary P.
    ANESTHESIOLOGY, 2012, 116 (04) : 834 - 840
  • [26] Regional cerebral oxygen saturation is a sensitive marker of cerebral hypoperfusion during orthotopic liver transplantation
    Plachky, J
    Hofer, S
    Volkmann, M
    Martin, E
    Bardenheuer, HJ
    Weigand, MA
    ANESTHESIA AND ANALGESIA, 2004, 99 (02): : 344 - 349
  • [27] PORTABLE REAL-TIME ANALYSIS SYSTEM FOR REGIONAL CEREBRAL BLOOD-FLOW
    TIERNAN, T
    ENTINE, G
    STUMP, DA
    PROUGH, DS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 698 - 702
  • [28] Effect of head elevation on intracranial pressure, cerebral perfusion pressure, and regional cerebral oxygen saturation in patients with cerebral hemorrhage
    Hernandez Palazon, J.
    Domenech Asensi, P.
    Burguillos Lopez, S.
    Perez Bautista, F.
    Garcia Candel, A.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2008, 55 (05): : 289 - 293
  • [29] Nitroglycerin and cerebral oxygen saturation
    Hare, Gregory M. T.
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2008, 55 (01): : 52 - 53
  • [30] Noninvasive cerebral oximeter as a surrogate for mixed venous saturation in children
    Bhutta, Adnan T.
    Ford, Jesse W.
    Parker, James G.
    Prodhan, Parthak
    Fontenot, Eudice E.
    Seib, Paul M.
    Stroope, Brittany I.
    Frazier, Elizabeth A.
    Schmitz, Michael L.
    Drummond-Webb, Jonathan J.
    Morrow, William R.
    PEDIATRIC CARDIOLOGY, 2007, 28 (01) : 34 - 41