Temporal pulsed x-ray response of CdZnTe:In detector

被引:0
|
作者
郭榕榕 [1 ,2 ]
徐亚东 [2 ]
查钢强 [2 ]
王涛 [2 ]
介万奇 [2 ]
机构
[1] School of Optoelectronic and Communication Engineering, Xiamen University of Technology
[2] State Key Laboratory of Solidification Processing, Northwestern Polytechnical University (NWPU)
基金
中国国家自然科学基金;
关键词
CdZnTe; ultrafast-pulsed x-rays; transient current; charge carrier;
D O I
暂无
中图分类号
TL81 [辐射探测技术和仪器仪表];
学科分类号
摘要
The temporal response of cadmium-zinc-telluride(CZT) crystals is evaluated at room temperature by using an ultrafast-pulsed x-ray source. The dynamics of carrier relaxation in a CZT single crystal is modeled at a microscopic level based on a multi-trapping effect. The effects of the irradiation flux and bias voltage on the amplitude and full width at half maximum(FWHM) of the transient currents are investigated. It is demonstrated that the temporal response process is affected by defect level occupation fraction. A fast photon current can be achieved under intense pulsed x-ray irradiation to be up to 2.78×10~9 photons mm-2·s-1. Meanwhile, it is found that high bias voltage could enhance carrier detrapping by suppressing the capture of structure defects and thus improve the temporal response of CZT detectors.
引用
收藏
页码:454 / 458
页数:5
相关论文
共 50 条
  • [21] CdZnTe and CdTe materials for X-ray and gamma ray radiation detector applications
    Szeles, C
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2004, 241 (03): : 783 - 790
  • [22] Hard x-ray response of pixellated CdZnTe detectors
    Abbene, L.
    Del Sordo, S.
    Caroli, E.
    Gerardi, G.
    Raso, G.
    Caccia, S.
    Bertuccio, G.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (12)
  • [23] CdZnTe detector arrays for low-dose x-ray fluoroscopy
    Heanue, JA
    Pearson, DA
    Melen, RE
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 114 - 121
  • [24] Performance of a prototype CdZnTe detector module for hard X-ray astrophysics
    Slavis, KR
    Dowkontt, P
    Duttweiler, F
    Epstein, JW
    Hink, PL
    Huszar, GL
    Kalemci, E
    Leblanc, PC
    Matteson, JL
    Pelling, MR
    Rothschild, RE
    Stephan, E
    Tümer, T
    Visser, G
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 249 - 256
  • [25] Detective quantum efficiency of flat panel CdZnTe x-ray detector
    Khym, GL
    Kim, KH
    Park, YJ
    Yang, HJ
    Kim, SU
    Jung, TR
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2004, 45 : S893 - S897
  • [26] On the correlation between crystal morphology and X-ray performance of a CdZnTe detector
    Bavdaz, M
    Peacock, A
    Nenonen, S
    Jantunen, MA
    Gagliardi, T
    Tuomi, T
    Hjelt, KT
    Juvonen, M
    Rantamaki, R
    Kraft, S
    Wedowski, M
    Scholze, F
    Ulm, G
    McNally, PJ
    Curley, J
    Danilewsky, AN
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 322 - 332
  • [27] Direct measurement of mammographic x-ray spectra using a CdZnTe detector
    Matsumoto, M
    Yamamoto, A
    Honda, I
    Taniguchi, A
    Kanamori, H
    MEDICAL PHYSICS, 2000, 27 (07) : 1490 - 1502
  • [28] CdZnTe x-ray detector for 30 similar to 100 keV energy
    Yoo, SS
    Rodricks, B
    Shastri, SD
    Montano, PA
    HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 : 50 - 56
  • [29] CdZnTe and CdTe detector arrays for hard X-ray and gamma-ray astronomy
    Stahle, CM
    Parker, BH
    Parsons, AM
    Barbier, LM
    Barthelmy, SD
    Gehrels, NA
    Palmer, DM
    Snodgrass, SJ
    Tueller, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 138 - 145
  • [30] CdZnTe and CdTe detector arrays for hard X-ray and gamma-ray astronomy
    NASA Goddard Space Flight Center, Greenbelt, MD 20771, United States
    不详
    不详
    Nucl Instrum Methods Phys Res Sect A, 1-2 (138-145):