Forced Compressed Air Cooling System for a 300 MW Steam Turbine in Waigaoqiao Power Plant

被引:0
|
作者
Sun Shixiong Hua Hong Shanghai Waigaoqiao Thermal Power Plant
机构
关键词
der; Forced Compressed Air Cooling System for a 300 MW Steam Turbine in Waigaoqiao Power Plant; ITI; 认认; test; 司卜; 月卜; HP; IP; 一基;
D O I
暂无
中图分类号
TM621.3 [发电设备];
学科分类号
080802 ;
摘要
The 300 MW steam turbine installed in Waigaoqiao Power Plant with combined HPIP cylinders of double casing structure is a product of the Shanghai Turbine Works utilizing licensed technology. It has a large heat storage capacity and good thermal insulation, so the metal temperature of first stage of HP cylinder (FSMTI) may reach 400-450℃ after shut down and it takes 7-8 days to cool to 150℃ by natural cooling, Now with a forced cooling system the cooling time may be reduced to 40 hours, so that the turbine may be opened for repair work in about 5-6 days. The cooling system for #2 unit and test procedure are briefly described below.
引用
收藏
页码:22 / 24
页数:3
相关论文
共 50 条
  • [1] Investigation and Application of Forced Cooling of WH 600MW Steam Turbine
    Shi, Yongfeng
    Xu, Jianqun
    Ma, Lin
    [J]. THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 242 - +
  • [2] Investigation of wet steam flow in a 300 MW direct air-cooling steam turbine. Part 2: flow field and windage
    Cai, X.
    Niu, F.
    Li, J.
    Su, M.
    Ning, T.
    Song, Y.
    Wu, G.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2010, 224 (A1) : 129 - 137
  • [3] An investigation of wet steam flow in a 300 MW direct air-cooling steam turbine. Part 3: heterogeneous/homogeneous condensation
    Cai, X.
    Niu, F.
    Ning, T.
    Wu, G.
    Song, Y.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2010, 224 (A4) : 583 - 589
  • [4] Design of an Inlet Air-Cooling System for a Gas Turbine Power Plant
    Unver, Umit
    Mert, Mehmet Selcuk
    Direk, Mehmet
    Yuksel, Fikret
    Kilic, Muhsin
    [J]. EXERGY FOR A BETTER ENVIRONMENT AND IMPROVED SUSTAINABILITY 1: FUNDAMENTALS, 2018, : 1089 - 1100
  • [5] Power control in the gas turbine section of a co-generation plant by air cooling and steam injection
    Dumitrascu, G
    Horbaniuc, B
    Marin, O
    Charon, O
    [J]. OCOS 2000: FROM THERMO-ECONOMICS TO SUSTAINABILITY, PTS 1-4, 2000, : 515 - 532
  • [6] Investigation of wet steam flow in a 300 MW direct air-cooling steam turbine. Part 1: measurement principles, probe, and wetness
    Cai, X.
    Ning, T.
    Niu, F.
    Wu, G.
    Song, Y.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A5) : 625 - 634
  • [7] On the possibility of using an industrial steam turbine as an air expander in a Compressed Air Energy Storage plant
    Salvini, Coriolano
    Giovannelli, Ambra
    Farhat, Hiyam
    [J]. JOURNAL OF ENERGY STORAGE, 2022, 55
  • [8] Reconstruction of the gland sealing system of a 300MW steam turbine unit
    Xie, DM
    Liu, GL
    Wang, JM
    Yang, J
    [J]. ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 862 - 866
  • [9] Exergy Analysis of a Steam Power Plant with Direct Air-cooling System in China
    Zhao Hongbin
    Chai Yuman
    [J]. 2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1000 - 1003
  • [10] THERMAL TESTS ON 300 MW STEAM TURBINE CONDENSERS
    KONOVALO.GM
    KIRSH, AK
    YEGOROV, VN
    KANAEV, VD
    [J]. THERMAL ENGINEERING, 1970, 17 (09) : 59 - &