Investigation and Application of Forced Cooling of WH 600MW Steam Turbine

被引:0
|
作者
Shi, Yongfeng [1 ,2 ]
Xu, Jianqun [1 ]
Ma, Lin
机构
[1] Southeast Univ, Sch Energy & Environm, Key Lab Energy Thermal Convers & Control, Minist Educ, Nanjing 210096, Jiangsu, Peoples R China
[2] HuaDian Elect Res Inst, Hangzhou 310030, Zhejiang, Peoples R China
关键词
Forced cooling; Natural cooling; Radiating mechanism; Control strategy;
D O I
10.4028/www.scientific.net/AMR.732-733.242
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With a long natural cooling time after a shutdown of steam turbine restricting its available coefficient, this paper presented the analysis and application of a forced cooling process to sub-critical steam turbine. The radiating mechanism of natural cooling was analyzed theoretically, and the required amount of cooling air was calculated for a WH 600MW steam turbine. Moreover, the cooling rate with no life loss principle was determined by the method of quantitative calculation and numerical analysis, together with safety analysis. The research discussed the control strategy of practical application according with steam turbine characteristic and applied to operation, which provided theoretical guidance for the optimization of cooling condition.
引用
收藏
页码:242 / +
页数:2
相关论文
共 50 条
  • [1] EFFECTS OF LEAKAGE COOLING ON IP ROTOR DISC AND ROOT IN 600MW STEAM TURBINE
    Yang, Jiandao
    Qi, Mingxu
    Zhou, Daiwei
    Yang, Hong
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 2, 2009, : 485 - 490
  • [2] Design of 600MW air cooled double exhaust steam turbine
    Shiquan, Zhao
    [J]. CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 345 - 349
  • [3] Shaft Crack Analysis and Diagnosis for the 600MW Steam Turbine Generator
    Jiang Dongxiang
    Hong Liangyou
    Huang Qian
    [J]. DAMAGE ASSESSMENT OF STRUCTURES VIII, 2009, 413-414 : 591 - 598
  • [4] Optimization Research on Nozzle Governing 600MW Steam Turbine Operation
    Li, Ling
    Xu, Jian-qun
    Li, Gang
    Zhou, Ke-yi
    Shi, Yong-feng
    [J]. 2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [5] STRENGTH AND RIGID ANALYSIS FOR EXHAUST EQUIPMENT OF 600MW SUPERCRITICAL DIRECT AIR-COOLING STEAM TURBINE
    Sun, Qing
    Wang, Xiu-jin
    Chen, Hong-xi
    Liu, Feng-zhen
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 3, 2009, : 375 - 379
  • [6] Optimization of Steam Governing Arrangement for 600MW Sub-critical Steam Turbine Unit
    Guo, Di
    Hu, Nian-su
    Wang, Jian-mei
    Huang, Mei
    Liu, Yong-hui
    Yi, Zhao-hui
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [7] Development of control system for supercritical 600MW steam turbine made in domestic
    Li, Yiliang
    Xie, Danmei
    Yang, Changzhu
    Dong, Chuan
    Wu, Yunpeng
    [J]. CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 634 - +
  • [8] Analysis and treatment of abnormal increase of bearing temperature of 600MW steam turbine
    Ma, Lyuzhou
    [J]. 2020 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND MATERIALS SCIENCE, 2020, 585
  • [9] Thermal Stress Analysis of 600MW Steam Turbine Rotor in Different Governing Modes
    Li, Yong
    Sun, Haoran
    Nie, Yuhuo
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [10] The numerical simulation of the shell side flow and heat transfer for 600MW steam turbine condenser
    Wang, Siping
    Zhang, Li
    Li, Jian
    [J]. ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 265 - 271