EFFECTS OF LEAKAGE COOLING ON IP ROTOR DISC AND ROOT IN 600MW STEAM TURBINE

被引:0
|
作者
Yang, Jiandao [1 ]
Qi, Mingxu
Zhou, Daiwei [1 ]
Yang, Hong [1 ]
机构
[1] Shanghai Elect Power Generat Equipment Co Ltd, Shanghai, Peoples R China
关键词
Leakage cooling; rotor groove; CHT;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Numerical simulation is performed on the first two stages of IP cylinder of a 600MW steam turbine using CFD and CHT methods. Cooling effects of HP cylinder leakage steam on IP cylinder rotor is investigated and flow behavior of the leakage steam in cooling passages is studied, with configurations of seals, root bottom gaps and diaphragm-to-disc gaps included. Efficient cooling effects are achieved on the rotor and blade root of the first stage, with highest temperature decrease being up to 90K. No obvious cooling effects are found on the second stage rotor blade and rotor disc. Maximum temperature of rotor groove for first and second stage appears at trailing and leading side of its meshing surface with root flat, with value being 796K and 803K separately, which are 41K and 34K lower than the temperature of IP cylinder fresh mean steam.
引用
收藏
页码:485 / 490
页数:6
相关论文
共 50 条
  • [1] Investigation and Application of Forced Cooling of WH 600MW Steam Turbine
    Shi, Yongfeng
    Xu, Jianqun
    Ma, Lin
    [J]. THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 242 - +
  • [2] Thermal Stress Analysis of 600MW Steam Turbine Rotor in Different Governing Modes
    Li, Yong
    Sun, Haoran
    Nie, Yuhuo
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [3] Shaft Crack Analysis and Diagnosis for the 600MW Steam Turbine Generator
    Jiang Dongxiang
    Hong Liangyou
    Huang Qian
    [J]. DAMAGE ASSESSMENT OF STRUCTURES VIII, 2009, 413-414 : 591 - 598
  • [4] Design of 600MW air cooled double exhaust steam turbine
    Shiquan, Zhao
    [J]. CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 345 - 349
  • [5] Optimization Research on Nozzle Governing 600MW Steam Turbine Operation
    Li, Ling
    Xu, Jian-qun
    Li, Gang
    Zhou, Ke-yi
    Shi, Yong-feng
    [J]. 2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [6] STRENGTH AND RIGID ANALYSIS FOR EXHAUST EQUIPMENT OF 600MW SUPERCRITICAL DIRECT AIR-COOLING STEAM TURBINE
    Sun, Qing
    Wang, Xiu-jin
    Chen, Hong-xi
    Liu, Feng-zhen
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON POWER ENGINEERING 2009 (ICOPE-09), VOL 3, 2009, : 375 - 379
  • [7] Optimization of Steam Governing Arrangement for 600MW Sub-critical Steam Turbine Unit
    Guo, Di
    Hu, Nian-su
    Wang, Jian-mei
    Huang, Mei
    Liu, Yong-hui
    Yi, Zhao-hui
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [8] Analysis and treatment of abnormal increase of bearing temperature of 600MW steam turbine
    Ma, Lyuzhou
    [J]. 2020 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND MATERIALS SCIENCE, 2020, 585
  • [9] Development of control system for supercritical 600MW steam turbine made in domestic
    Li, Yiliang
    Xie, Danmei
    Yang, Changzhu
    Dong, Chuan
    Wu, Yunpeng
    [J]. CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 634 - +
  • [10] ANALYSIS OF HIGH TEMPERATURE CREEP ON THE NUT CONNECTION COMPONENTS OF A 600MW SUPERCRITICAL STEAM TURBINE
    Jiang, P. N.
    Wang, W. Z.
    Jiao, G. C.
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 5, 2012, : 145 - 151