Measurement of central corneal thickness and precorneal tear film thickness of rabbits using the Scheimpflug system

被引:0
|
作者
Jing Dong [1 ]
Qiang Wu [2 ]
Xiao-Gang Wang [2 ]
机构
[1] Department of Ophthalmology,the First Hospital of Shanxi Medical University
[2] Department of Ophthalmology,the Sixth People's Hospital Affiliated to Shanghai Jiaotong University
关键词
tear film; Scheimpflug; rabbits; central corneal thickness; fluorescein;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM:To measure central corneal thickness(CCT) and pre-corneal tear film thickness using the Galilei dual Scheimpflug analyzer(GSA) in New Zealand White rabbits.METHODS:Ten normal New Zealand White rabbits(20 eyes) were included in this study.With the assistance of 0.1% fluorescein,the pre-corneal tear film can be well visualized.Both eyes of each rabbit were scanned once with the GSA pre- and post-instillation of 1μL 0.1% fluorescein.The difference between the two measurements of CCT(4-mm diameter) was recorded as the pachymetric values of the central tear film.RESULTS:The CCT of pre- and post-instillation was 388.8±9.5μm and 407.0±10.5μm,respectively.After a paired t-test analysis,the central pre-corneal tear film thickness of 4mm diameter was 18.2±5.31μm with a 95% confidence interval of(15.7,20.6)μm(P<0.001).CONCLUSION:GSA can be used to measure CCT and analyze central tear film thickness of rabbits with the help of fluorescein.
引用
收藏
页码:584 / 587
页数:4
相关论文
共 50 条
  • [1] Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system
    Dong, Jing
    Wu, Qiang
    Wang, Xiao-Gang
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (05) : 584 - 587
  • [2] MEASUREMENT OF THE PRECORNEAL TEAR FILM THICKNESS WITH A NONCONTACT OPTICAL INTERFEROMETRY FILM THICKNESS MEASUREMENT SYSTEM
    DANJO, Y
    NAKAMURA, M
    HAMANO, T
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 1994, 38 (03) : 260 - 266
  • [3] Effect of Fluorescein Dye Staining of the Tear Film on Scheimpflug Measurements of Central Corneal Thickness
    Hirnschall, Nino
    Crnej, Alja
    Gangwani, Vinod
    Findl, Oliver
    [J]. CORNEA, 2012, 31 (01) : 18 - 20
  • [4] Effects of Computer Usage on Tear Film Osmolarity and Precorneal Tear Film Thickness
    Chu, Stephanie
    Bohm, Kelley
    Chapman, Kristin
    Starr, Christopher
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Interferometric imaging of the full thickness of the precorneal tear film
    King-Smith, P. Ewen
    Fink, Barbara A.
    Nichols, Jason J.
    Nichols, Kelly K.
    Hill, Richard M.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2006, 23 (09) : 2097 - 2104
  • [6] STUDY OF HUMAN PRECORNEAL TEAR FILM THICKNESS AND STRUCTURE USING LASER INTERFEROMETRY
    PRYDAL, JI
    ARTAL, P
    HONG, W
    CAMPBELL, FW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (06) : 2006 - 2011
  • [7] Interferometry in the Evaluation of Precorneal Tear Film Thickness in Dry Eye
    Hosaka, Eri
    Kawamorita, Takushi
    Ogasawara, Yuko
    Nakayama, Nanami
    Uozato, Hiroshi
    Shimizu, Kimiya
    Dogru, Murat
    Tsubota, Kazuo
    Goto, Eiki
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (01) : 18 - 23
  • [8] MEASUREMENT OF TEAR FILM THICKNESS USING FLUOROPHOTOMETRY
    YUN, YS
    MCCAREY, BE
    AMOS, C
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1470 - 1470
  • [9] Reproducibility, Repeatability, and Correlation of Central Corneal Thickness Measurement with the Pentacam Scheimpflug System and Ultrasound Pachymetry
    Macias-Rodriguez, Yolanda
    Ramos-Davila, Eugenia M.
    Ruiz-Lozano, Raul E.
    Reyes-Arena, Jose, V
    Jocelyn Rivera-Alvarado, I
    Hernandez-Camarena, Julio C.
    Rodriguez-Garcia, Alejandro
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2022,
  • [10] The thickness of the human precorneal tear film: Evidence from reflection spectra
    King-Smith, PE
    Fink, BA
    Fogt, N
    Nichols, KK
    Hill, RM
    Wilson, GS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (11) : 3348 - 3359