Feasibility Analysis of Back-Pressure Steam Feeding Water Pump for Direct Air-Cooled Unit

被引:1
|
作者
Zhao Xiaodong [1 ]
Wang Meng [1 ]
Du Xiaoze [1 ]
Yang Lijun [1 ]
Yang Yongping [1 ]
机构
[1] Key laboratory of Condition Monitoring and Control for Power Plant Equipment,North China Electric Power University
关键词
air-cooled; back-pressure steam turbine; steam feed water pump; variable condition;
D O I
暂无
中图分类号
TM311 [汽轮发电机];
学科分类号
080801 ;
摘要
As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introduces a new design of for steam feeding the water pump of an air-cooled unit using the back-pressure steam turbine as the prime motor. Using variable condition analysis on a 600 MW direct air-cooled unit, and with consideration of the effect on the ambient conditions, the feasibility, economy, and adaptability of the design are verified.
引用
收藏
页码:31 / 35
页数:5
相关论文
共 50 条
  • [1] Analysis on the Back-pressure Optimum Operation of the Direct Air-cooled Condenser
    Zhao, Hongbin
    Wu, Haixia
    Cao, Ling
    [J]. 2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [2] Study on the Optimal Back-pressure of Direct Air-cooled Condenser in Theory
    Zhao Hongbin
    Cao Ling
    [J]. 2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1004 - 1007
  • [3] Scheme Design and Analysis of Variable Condition of Evaporative Condenser for Steam Condensing of Steam Feeding Water Pump for 1000MW Air-cooled Unit
    Wei, Gaosheng
    Ren, Jingqiu
    Hong, Wenpeng
    [J]. 2012 INTERNATIONAL CONFERENCE ON FUTURE ELECTRICAL POWER AND ENERGY SYSTEM, PT B, 2012, 17 : 1177 - 1184
  • [4] 600 MW Direct Air-Cooling Unit Back-Pressure Optimization and Theoretical Analysis
    Zhao, Hongbin
    Yan, Yonghui
    Li, Meng
    [J]. MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 : 1739 - 1743
  • [5] Pressure drop analysis of steam condensation in air-cooled circular tube bundles
    O'Donovan, Alan
    Grimes, Ronan
    [J]. APPLIED THERMAL ENGINEERING, 2015, 87 : 106 - 116
  • [6] DEVIATION ANALYSIS ON FLOW AND HEAT TRANSFER MODEL OF LARGE AIR-COOLED STEAM CONDENSER UNIT
    Lv, Yi
    Zhang, Hui
    Yue, Yujin
    Yang, Lijun
    Zhang, XiaoDong
    [J]. ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 656 - +
  • [7] Pressure Forecast of an Air-cooled Steam Condenser under Wind Speeds
    He, Weifeng
    Dai, Yiping
    [J]. MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 6187 - 6193
  • [8] Performance monitoring of direct air-cooled power generating unit with infrared thermography
    Ge, Zhihua
    Du, Xiaoze
    Yang, Lijun
    Yang, Yongping
    Li, Yanlei
    Jin, Yansheng
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (04) : 418 - 424
  • [9] Influence of Swirlers on Flow and Heat-transfer in Direct Air-cooled Condenser Unit
    Cheng, You Liang
    Zhang, Ning
    Ren, Ze Min
    Guo, Fei
    [J]. HEAT TRANSFER ENGINEERING, 2018, 39 (15) : 1377 - 1391
  • [10] Closed-loop Design and Simulation Analysis for Condenser Pressure Control on Direct Air-cooled Units
    Liu, Hui-chao
    Wang, Wei
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING, MATERIALS AND ENERGY (5TH ICMEME2016), 2016, 90 : 139 - 142