Pressure drop analysis of steam condensation in air-cooled circular tube bundles

被引:17
|
作者
O'Donovan, Alan [1 ]
Grimes, Ronan [1 ]
机构
[1] Univ Limerick, Stokes Inst, Dept Mech Aeronaut & Biomed Engn, Limerick, Ireland
关键词
Air-cooling; Condensation; Two-phase flow; Pressure drop; SOLAR POWER-PLANT; THERMODYNAMIC PERFORMANCE; FLOW; CONDENSERS; WIND; GRADIENTS; FRICTION;
D O I
10.1016/j.applthermaleng.2015.04.072
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pressure losses on the condensing-side of an air-cooled condenser (ACC) have the potential to inhibit condenser performance and, ultimately, curtail plant efficiency. However, little information is available on the magnitude and effect of these losses in an ACC under typical Rankine cycle operating conditions. This article seeks to improve current understanding on steam-side pressure losses in ACCs by presenting an experimental study on the losses in a full-scale ACC circular tube bundle. Saturated steam at low pressure was condensed by a cross flow of cooling air, provided by a bank of axial fans. Full condensation occurred in all measurements, which were carried-out over a steam pressure and temperature range of approximately 0.05-0.14 bar absolute and 33-55 degrees C, respectively. These test parameters ensured that measurement program test conditions were representative of those expected in an operational thermoelectric power plant. Experimental mass fluxes, per individual tube, varied from 0.7 to 2 kg/m(2) s during testing. The pressure drop characteristics were, therefore, analysed over a vapour Reynolds numbers range of 1890-5150 and liquid Reynolds number range of 25-95. Results indicate that the measured pressure drop through the tube bundle was relatively small, in the range of 130-250 Pa. As shown in this article, the reason for this was due to momentum recovery as the steam condenses to form liquid condensate. This phenomenon offsets the frictional losses, which are shown to be comparable in magnitude to momentum recovery in a condensing flow. However, this may not always be the case. Therefore, since the frictional component is traditionally the most problematic to predict, a range of liquid gas two-phase frictional pressure drop predictive models were reviewed, and are presented herein. Comparisons between these models and the experimental data show that the most applicable model was found to be that of Lockhart & Martinelli. This demonstrated reasonable accuracy of +/- 18%. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:106 / 116
页数:11
相关论文
共 50 条
  • [1] CHARACTERISTICS OF TUBE BUNDLES FOR AIR-COOLED EXCHANGERS
    KUNTYSH, VB
    PIIR, AE
    FEDOTOVA, LM
    TALVING, TA
    VARMA, KA
    [J]. CHEMISTRY AND TECHNOLOGY OF FUELS AND OILS, 1980, 16 (5-6) : 312 - 315
  • [2] Numerical investigation of condensation in inclined tube air-cooled condensers
    Kekaula, Kaipo
    Chen, Yitung
    Ma, Ting
    Wang, Qiu-Wang
    [J]. APPLIED THERMAL ENGINEERING, 2017, 118 : 418 - 429
  • [3] MULTISTAGE ARRANGEMENT OF CONDENSATION IN AIR-COOLED STEAM POWER-STATIONS
    KELP, F
    [J]. BRENNSTOFF-WARME-KRAFT, 1972, 24 (09): : 333 - &
  • [4] Modeling steam condensation from steam-air mixture in the inclined tubes of an air-cooled condenser
    Artemov V.I.
    Minko K.B.
    Yan'Kov G.G.
    [J]. Thermal Engineering, 2014, 61 (1) : 30 - 40
  • [5] Thermo-hydraulic model for steam condensation in a large, inclined, flattened-tube air-cooled condenser
    Davies, William A., III
    Hrnjak, Pega
    [J]. APPLIED THERMAL ENGINEERING, 2019, 149 : 745 - 756
  • [6] Analysis of steam condensation characteristics in the presence of air outside the ring fin tube bundles
    Gao, Li
    Li, Wentao
    Mao, Yawei
    Zhang, Chaoqi
    Li, Li
    [J]. Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (07): : 1201 - 1207
  • [7] Challenges in predicting steam-side pressure drop and heat transfer in air-cooled power plant condensers
    Mahvi, Allison J.
    Rattner, Alexander S.
    Lin, Jennifer
    Garimella, Srinivas
    [J]. APPLIED THERMAL ENGINEERING, 2018, 133 : 396 - 406
  • [8] Co-current Condensation in an Inclined Air-cooled Flat Tube with Fins
    Cheng, Tongrui
    Du, Xiaoze
    Yang, Lijun
    Yang, Yongping
    [J]. CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 3154 - 3161
  • [9] Experimental Study on the Condensation of Steam With Air Out of the Vertical Tube Bundles
    Wang, Lu
    Chen, Ping
    Zhou, Yi
    Li, Wei
    Tang, Changbing
    Miao, Yifei
    Meng, Zhaoming
    [J]. FRONTIERS IN ENERGY RESEARCH, 2018, 6
  • [10] Effects of Airflow Profile and Condensation Pressure on Performance of Air-Cooled Condensers
    Davies, William A., III
    Hrnjak, Pega
    [J]. HEAT TRANSFER ENGINEERING, 2020, 41 (22) : 1843 - 1855