Study on the Optimal Back-pressure of Direct Air-cooled Condenser in Theory

被引:0
|
作者
Zhao Hongbin [1 ]
Cao Ling [1 ]
机构
[1] China Univ Petr, Sch Mechatron Engn, Beijing 102249, Peoples R China
关键词
direct air-cooling; turbine power; fan power consumed; the optimal back-pressure;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to improve the system running economics of the direct air-cooled unit, based on the thermodynamic model of the air-cooled system, through considering the steam turbine power and the consumption power of fan, this article has researched the optimal back-pressure of the unit in theory under the running conditions, and given the basic law about the optimal back-pressure affected by the corresponding main factors. Thus, the results of studying will provide helpful guidance for the cold-end optimization and economical running of the direct air-cooled thermal power plants.
引用
收藏
页码:1004 / 1007
页数:4
相关论文
共 50 条
  • [1] Analysis on the Back-pressure Optimum Operation of the Direct Air-cooled Condenser
    Zhao, Hongbin
    Wu, Haixia
    Cao, Ling
    [J]. 2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [2] Feasibility Analysis of Back-Pressure Steam Feeding Water Pump for Direct Air-Cooled Unit
    Zhao Xiaodong
    Wang Meng
    Du Xiaoze
    Yang Lijun
    Yang Yongping
    [J]. Electricity, 2013, 24 (01) : 31 - 35
  • [3] Optimizing Design of Direct Air-cooled Condenser
    Wang, Xuedong
    Zheng, Yanjuan
    Luan, Tao
    [J]. PROGRESS IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2012, 354-355 : 406 - +
  • [4] Optimization and application for direct air-cooled condenser automatic cleaning device
    Zhao, Qun
    Liu, Feng
    Sun, Zhen
    [J]. MANUFACTURING PROCESS AND EQUIPMENT, PTS 1-4, 2013, 694-697 : 3016 - 3019
  • [5] Experimental study on the evaporative cooling of an air-cooled condenser with humidifying air
    Wen, Mao-Yu
    Ho, Ching-Yen
    Jang, Kuang-
    Yeh, Cheng-Hsiung
    [J]. HEAT AND MASS TRANSFER, 2014, 50 (02) : 225 - 233
  • [6] Experimental study on the evaporative cooling of an air-cooled condenser with humidifying air
    Mao-Yu Wen
    Ching-Yen Ho
    Kuang-Jang Jang
    Cheng-Hsiung Yeh
    [J]. Heat and Mass Transfer, 2014, 50 : 225 - 233
  • [7] Pressure Forecast of an Air-cooled Steam Condenser under Wind Speeds
    He, Weifeng
    Dai, Yiping
    [J]. MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 6187 - 6193
  • [8] A STUDY ON AIR-COOLED CHILLERS WITH EVAPORATIVELY COOLED CONDENSER FOR 3 TYPES OF CLIMATE
    Kocak Soylu, Sezgi
    Atmaca, Ibrahim
    [J]. ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2016, 36 (01) : 1 - 8
  • [9] Closed-loop Design and Simulation Analysis for Condenser Pressure Control on Direct Air-cooled Units
    Liu, Hui-chao
    Wang, Wei
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING, MATERIALS AND ENERGY (5TH ICMEME2016), 2016, 90 : 139 - 142
  • [10] EFFECT OF WIND ON AIR-COOLED CONDENSER PERFORMANCE
    Maulbetsch, John S.
    DiFilippo, Michael N.
    O'Hagan, Joseph
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 1, 2012, : 391 - +