Optical performance of toric intraocular lenses in the presence of decentration

被引:0
|
作者
Bin Zhang [1 ]
Jin-Xue Ma [1 ]
Dan-Yan Liu [1 ]
Ying-Hua Du [1 ]
Cong-Rong Guo [1 ]
Yue-Xian Cui [1 ]
机构
[1] Department of Ophthalmology the Second Hospital of Hebei Medical University
关键词
lens; artificial; astigmatism; cornea; decentration; model;
D O I
暂无
中图分类号
R779.6 [眼外科手术学];
学科分类号
100212 ;
摘要
· AIM: To evaluate the optical performance of toric intraocular lenses(IOLs) after decentration and with different pupil diameters, but with the IOL astigmatic axis aligned.· METHODS: Optical performances of toric T5 and SN60 AT spherical IOLs after decentration were tested on a theoretical pseudophakic model eye based on the Hwey-Lan Liou schematic eye using the Zemax ray-tracing program. Changes in optical performance were analyzed in model eyes with 3-mm, 4-mm, and 5-mm pupil diameters and decentered from 0.25 mm to 0.75 mm with an interval of 5° at the meridian direction from0° to 90°. The ratio of the modulation transfer function(MTF) between a decentered and a centered IOL(MTFDecentration/MTFCentration) was calculated to analyze the decrease in optical performance.· RESULTS: Optical performance of the toric IOL remained unchanged when IOLs were decentered in any meridian direction. The MTFs of the two IOLs decreased,whereas optical performance remained equivalent after decentration. The MTFDecentration/MTFCentrationratios of the IOLs at a decentration from 0.25 mm to 0.75 mm were comparable in the toric and SN60 AT IOLs. After decentration, MTF decreased further, with the MTF of the toric IOL being slightly lower than that of the SN60 AT IOL. Imaging qualities of the two IOLs decreased when the pupil diameter and the degree of decentration increased, but the decrease was similar in the toric and spherical IOLs.· CONCLUSION: Toric IOLs were comparable to spherical IOLs in terms of tolerance to decentration at the correct axial position.
引用
收藏
页码:730 / 735
页数:6
相关论文
共 50 条
  • [21] Toric intraocular lenses and correction of astigmatism
    Viestenz, Arne
    Walter, S.
    Viestenz, Anja
    Behrens-Baumann, W.
    Langenbucher, A.
    OPHTHALMOLOGE, 2007, 104 (07): : 620 - 627
  • [22] Optimizing outcomes with toric intraocular lenses
    Kaur, Manpreet
    Shaikh, Farin
    Falera, Ruchita
    Titiyal, Jeewan S.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1301 - 1313
  • [23] Toric intraocular lenses [Torische Intraokularlinsen]
    Auffarth G.U.
    Der Ophthalmologe, 2007, 104 (12): : 1022 - 1023
  • [24] Calculation of Pseudophakic Toric Intraocular Lenses
    Eppig, T.
    Viestenz, A.
    Seitz, B.
    Langenbucher, A.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2011, 228 (08) : 681 - 689
  • [25] Refractive Outcomes for Toric Intraocular Lenses
    Simpson, Michael J.
    ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (07) : 945 - 946
  • [26] Evaluation of Decentration, Tilt and Angular Orientation of Toric Intraocular Lens
    Fus, Martin
    Pitrova, Sarka
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 4755 - 4761
  • [27] Optical performance of multifocal intraocular lenses
    Jacobi, F. K.
    Kessler, W.
    Held, S.
    OPHTHALMOLOGE, 2007, 104 (03): : 236 - 242
  • [28] Tilt and decentration with various intraocular lenses: A narrative review
    Xiao-Yong Chen
    Yu-Chen Wang
    Tian-Yao Zhao
    Zi-Zhen Wang
    Wei Wang
    World Journal of Clinical Cases, 2022, (12) : 3639 - 3646
  • [29] Tilt and decentration with various intraocular lenses: A narrative review
    Chen, Xiao-Yong
    Wang, Yu-Chen
    Zhao, Tian-Yao
    Wang, Zi-Zhen
    Wang, Wei
    WORLD JOURNAL OF CLINICAL CASES, 2022, 10 (12) : 3639 - 3646
  • [30] Effect of Decentration on the Optical Quality of Monofocal, Extended Depth of Focus, and Bifocal Intraocular Lenses
    Xu, Jie
    Zheng, Tianyu
    Lu, Yi
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (08) : 484 - +