Optical performance of toric intraocular lenses in the presence of decentration

被引:0
|
作者
Bin Zhang [1 ]
Jin-Xue Ma [1 ]
Dan-Yan Liu [1 ]
Ying-Hua Du [1 ]
Cong-Rong Guo [1 ]
Yue-Xian Cui [1 ]
机构
[1] Department of Ophthalmology the Second Hospital of Hebei Medical University
关键词
lens; artificial; astigmatism; cornea; decentration; model;
D O I
暂无
中图分类号
R779.6 [眼外科手术学];
学科分类号
100212 ;
摘要
· AIM: To evaluate the optical performance of toric intraocular lenses(IOLs) after decentration and with different pupil diameters, but with the IOL astigmatic axis aligned.· METHODS: Optical performances of toric T5 and SN60 AT spherical IOLs after decentration were tested on a theoretical pseudophakic model eye based on the Hwey-Lan Liou schematic eye using the Zemax ray-tracing program. Changes in optical performance were analyzed in model eyes with 3-mm, 4-mm, and 5-mm pupil diameters and decentered from 0.25 mm to 0.75 mm with an interval of 5° at the meridian direction from0° to 90°. The ratio of the modulation transfer function(MTF) between a decentered and a centered IOL(MTFDecentration/MTFCentration) was calculated to analyze the decrease in optical performance.· RESULTS: Optical performance of the toric IOL remained unchanged when IOLs were decentered in any meridian direction. The MTFs of the two IOLs decreased,whereas optical performance remained equivalent after decentration. The MTFDecentration/MTFCentrationratios of the IOLs at a decentration from 0.25 mm to 0.75 mm were comparable in the toric and SN60 AT IOLs. After decentration, MTF decreased further, with the MTF of the toric IOL being slightly lower than that of the SN60 AT IOL. Imaging qualities of the two IOLs decreased when the pupil diameter and the degree of decentration increased, but the decrease was similar in the toric and spherical IOLs.· CONCLUSION: Toric IOLs were comparable to spherical IOLs in terms of tolerance to decentration at the correct axial position.
引用
收藏
页码:730 / 735
页数:6
相关论文
共 50 条
  • [1] Optical performance of toric intraocular lenses in the presence of decentration
    Zhang, Bin
    Ma, Jin-Xue
    Liu, Dan-Yan
    Guo, Cong-Rong
    Cui, Yue-Xian
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (04) : 730 - 735
  • [2] Effect of Decentration on the Optical Performance in Multifocal Intraocular Lenses
    Soda, Mitsutaka
    Yaguchi, Shigeo
    OPHTHALMOLOGICA, 2012, 227 (04) : 197 - 204
  • [3] Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system: Influence of pupil size, decentration, and rotation
    Kim, Min-Ji
    Yoo, Young-Sik
    Joo, Choun-Ki
    Yoon, Geunyoung
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2274 - 2282
  • [4] Optical performance of 3 intraocular lens designs in the presence of decentration
    Altmann, GE
    Nichamin, LD
    Lane, SS
    Pepose, JS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (03): : 574 - 585
  • [5] Effect of Decentration on the Optical Quality of Two Intraocular Lenses
    Ortiz, Carolina
    Esteve-Taboada, Jose J.
    Belda-Salmeron, Lurdes
    Monsalvez-Romin, Daniel
    Dominguez-Vicent, Alberto
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (12) : 1552 - 1559
  • [6] Impact of residual astigmatism on optical and visual performance for toric intraocular lenses
    Canovas, Carmen
    Piers, Patricia
    Sun, Mengchan
    Alarcon, Aixa
    Weeber, Henk A.
    Waring, George
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [7] Effect of Decentration, Rotation, and Tilt on Objective Optical Quality of Plate Haptic Toric Intraocular Lenses in the Early Postoperative Period
    Hong, Yingying
    Sun, Yang
    Liu, Houyi
    Ji, Yinghong
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (02):
  • [8] Toric intraocular lenses
    Auffarth, G. U.
    OPHTHALMOLOGE, 2007, 104 (12): : 1022 - 1023
  • [9] Evaluation of rotation and decentration of intraocular lenses
    Becker, KA
    Auffarth, GU
    Völcker, HE
    OPHTHALMOLOGE, 2004, 101 (06): : 600 - 603
  • [10] Status of toric intraocular lenses
    Horn, Jeffrey D.
    CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (01) : 58 - 61