Effect of Decentration on the Optical Quality of Two Intraocular Lenses

被引:24
|
作者
Ortiz, Carolina [1 ]
Esteve-Taboada, Jose J. [2 ]
Belda-Salmeron, Lurdes [2 ]
Monsalvez-Romin, Daniel [2 ]
Dominguez-Vicent, Alberto [2 ]
机构
[1] Univ Granada, Dept Opt, Lab Vis Sci & Applicat, Campus Fuentenueva S-N,Edificio Mecenas, E-18071 Granada, Spain
[2] Univ Valencia, Dept Opt, Optometry Res Grp, Valencia, Spain
关键词
multifocal intraocular lens; optical quality; optical bench; modulation transfer function; decentration; MODULATION TRANSFER-FUNCTION; SPHERICAL-ABERRATION; CONTRAST SENSITIVITY; VISUAL PERFORMANCE; TILT; OUTCOMES; IMPLANTATION; SIMULATION; PROFILE; DESIGNS;
D O I
10.1097/OPX.0000000000001004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To analyze the effect of decentration on the optical quality of two diffractive-refractive intraocular lenses, a bifocal and a trifocal, when displaced laterally (horizontal direction) from the center. Methods. The AT LISA 809M IOL (+3.75 D add) with two main foci and the AT LISA tri 839MP intraocular lens with three main foci (Carl Zeiss MeditecAG, Jena, Germany) were analyzed. The optical quality of the intraocular lenses was measured with the PMTF (power and modulation transfer function [MTF] measurement for refractive and diffractive intraocular lenses) optical bench (Lambda-X, Nivelles, Belgium). The optical quality of the lenses was evaluated by the MTF at different object vergences, the average modulation in the range of frequencies from 0 to 100 cycles/mm, and the through-focus MTF curves. All measures were recorded when the intraocular lenses were centered and decentered for 3.0-and 4.5-mm apertures. The Strehl ratio and the percentage of energy allocated at each focus at the centered position were also obtained. Results. Our results showed a lower optical quality with increasing decentration. The MTFs for the diffractive-refractive intraocular lenses decreased when the intraocular lenses were decentered. Also, the relative percentages of light energy allocated at each object vergence, for both intraocular lenses, agreed well with theoretical specifications and were consistent with the overall design of each lens. Conclusions. The optical quality of these diffractive-refractive multifocal intraocular lenses was slightly reduced when the induced decentration was less than 0.4 mm. For a decentration of 0.4 mm, the maximum difference in average modulation values was about 18% compared to the centered position.
引用
收藏
页码:1552 / 1559
页数:8
相关论文
共 50 条
  • [1] Effect of decentration and tilt on the in vitro optical quality of monofocal and trifocal intraocular lenses
    Pan, Ruo-Lin
    Tan, Qing-Qing
    Liao, Xuan
    Xie, Li-Xuan
    Qin, Su-Yun
    Tang, Yu-Ling
    Lan, Chang-Jun
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024,
  • [2] Effect of Decentration on the Optical Performance in Multifocal Intraocular Lenses
    Soda, Mitsutaka
    Yaguchi, Shigeo
    [J]. OPHTHALMOLOGICA, 2012, 227 (04) : 197 - 204
  • [3] Effect of Decentration on the Optical Quality of Monofocal, Extended Depth of Focus, and Bifocal Intraocular Lenses
    Xu, Jie
    Zheng, Tianyu
    Lu, Yi
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (08) : 484 - +
  • [4] Optical performance of toric intraocular lenses in the presence of decentration
    Zhang, Bin
    Ma, Jin-Xue
    Liu, Dan-Yan
    Guo, Cong-Rong
    Cui, Yue-Xian
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (04) : 730 - 735
  • [5] Optical performance of toric intraocular lenses in the presence of decentration
    Bin Zhang
    Jin-Xue Ma
    Dan-Yan Liu
    Ying-Hua Du
    Cong-Rong Guo
    Yue-Xian Cui
    [J]. International Journal of Ophthalmology, 2015, (04) : 730 - 735
  • [6] Effect of decentration on the quality of vision in two aspheric posterior chamber intraocular lenses: A contralateral eye study
    Thakur, Anchal
    Adiga, Sushant
    Malhotra, Chintan
    Sachdeva, Kulbhushan
    Singh, Shubhi
    Jain, Arun Kumar
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (04) : 558 - 564
  • [7] Investigation of the theoretical image quality of aspheric intraocular lenses by decentration
    Gillner, M.
    Langenbucher, A.
    Eppig, T.
    [J]. OPHTHALMOLOGE, 2012, 109 (03): : 263 - 270
  • [8] Effect of Decentration, Rotation, and Tilt on Objective Optical Quality of Plate Haptic Toric Intraocular Lenses in the Early Postoperative Period
    Hong, Yingying
    Sun, Yang
    Liu, Houyi
    Ji, Yinghong
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (02):
  • [9] Evaluation of rotation and decentration of intraocular lenses
    Becker, KA
    Auffarth, GU
    Völcker, HE
    [J]. OPHTHALMOLOGE, 2004, 101 (06): : 600 - 603
  • [10] Simulation of Decentration of Intraocular Lenses With Positive and Negative Spherical Aberration: Effects on Wavefront Error and Optical Quality
    Baumeister, M.
    Buehren, J.
    Kohnen, T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)