Waste heat water pumping model with direct contact cooling

被引:0
|
作者
Kittiwoot Sutthivirode [1 ]
Naris Pratinthong [1 ]
Pichai Namprakai [1 ]
Natthaphon Roonprasang [2 ]
Taveewat Suparos [3 ]
机构
[1] Division of Energy Technology, School of Energy, Environment and Materials,King Mongkut's University of Technology Thonburi
[2] Department of Alternative Energy Development and Efficiency Ministry of Energy,Bureau of Energy Regulation and Conservation  3. Department of Mechanical Technology Education, Faculty of Industrial Edu
关键词
direct contact cooling; driving tank; steam-air power; liquid piston; waste heat;
D O I
暂无
中图分类号
X706 [废热利用]; TH38 [各种用途];
学科分类号
摘要
The performance of a patented water pumping model with steam-air power was presented, which operates automatically by direct contact cooling method. The main objective was to study feasibility of a pumping model for underground water. In this model, a heater installed within the heat tank represented sources of waste heat as energy input for finding appropriate conditions of the 10 L pump model. The system operation had five stages: heating, pumping, vapor flow, cooling, and water suction. The overall water heads of 3, 4.5, 6 and 7.5 m were tested. At the same time, it was found that the pump with 50% air volume is sufficient for pumping water to a desired level. In the experiment, the temperatures in the heating and pumping stages were 100-103 °C and 80-90 °C, respectively. The pressure in the pumping stage was 12-18 kPa, and the pressure in the suction stage was about-80 kPa, sufficient for the best performance. It could pump 170 L of water at a 2 m suction head, 120 L at a 3.5 m suction head, 100 L at a 5 m suction head, and 65 L at a 6.5 m suction head in 2 h. A mathematical model for larger pumps was also presented, which operates nearly the same as the present system. Economic analysis of the 10 L pump was also included.
引用
收藏
页码:3896 / 3910
页数:15
相关论文
共 50 条
  • [31] TUBE COOLING AT THE LAMINATED FLOW IN A HORIZONTAL WATER TUBE OF A WASTE HEAT BOILER
    DOLEZAL, R
    BRENNSTOFF-WARME-KRAFT, 1991, 43 (7-8): : 364 - 367
  • [32] Solid sorption heat powered cycles for cooling and heat pumping applications
    Meunier, F
    APPLIED THERMAL ENGINEERING, 1998, 18 (9-10) : 715 - 729
  • [33] Heat Balancing in Cooling Systems using Distributed Pumping
    Kallesoe, Carsten Skovmose
    Nielsen, Brian Kongsgaard
    Tsouvalas, Agisilaos
    IFAC PAPERSONLINE, 2020, 53 (02): : 3292 - 3297
  • [34] Heat transfer in direct contact condensation of steam to subcooled water spray
    Takahashi, M
    Nayak, AK
    Kitagawa, S
    Murakoso, H
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2001, 123 (04): : 703 - 710
  • [35] Modeling a Direct Contact Heat Exchanger used in a supercritical water loop
    Cascella, F.
    Teyssedou, A.
    APPLIED THERMAL ENGINEERING, 2015, 79 : 132 - 139
  • [36] Performances of Gas-Water Direct-Contact Heat Transfer
    Li, Feng
    Duanmu, Lin
    Fu, Lin
    Zhao, Xiling
    COLD CLIMATE HVAC 2018: SUSTAINABLE BUILDINGS IN COLD CLIMATES, 2019, : 63 - 77
  • [37] New intra-adsorbent heat/mass transfer model for waste heat adsorption cooling
    Zhang, Lizhi
    Wang, Li
    Wang, Ling
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 1999, 50 (06): : 818 - 825
  • [38] Water temperature model of surface water heat pump and analysis of water capacity for cooling
    Dep. of Urban Construction, Nanjing University of Technology, Nanjing 210009, China
    不详
    Taiyangneng Xuebao, 2009, 10 (1198-1202):
  • [39] Experimental and numerical study of waste heat recovery characteristics of direct contact thermoelectric generator
    Kim, Tae Young
    Negash, Assmelash
    Cho, Gyubaek
    ENERGY CONVERSION AND MANAGEMENT, 2017, 140 : 273 - 280
  • [40] Evaporative cooling and sensible heat recovery enable practical waste-heat driven water purification
    Jaiswal, Ankush Kumar
    Srivastava, Rishabh
    Jayakumar, Arjun
    Ahmad, Aqbal
    Naidu, Gayathri
    Swaminathan, Jaichander
    DESALINATION, 2024, 586