Performances of Gas-Water Direct-Contact Heat Transfer

被引:1
|
作者
Li, Feng [1 ]
Duanmu, Lin [1 ]
Fu, Lin [2 ]
Zhao, Xiling [2 ]
机构
[1] Dalian Univ Technol, Fac Infrastruct Engn, Sch Civil Engn, Dalian, Liaoning, Peoples R China
[2] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing, Peoples R China
关键词
Direct-contact; Flue-gas condensation; Motion characteristics; Heat and mass exchange; Heat transfer model; Test verification;
D O I
10.1007/978-3-030-00662-4_6
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Compared with indirect-contact heat exchanger, gas-water direct-contact heat exchanger has superiority of decreasing metal heat-exchange surface, small temperature difference and volume, less investment and good antiseptic effect. This paper studies the droplets movement characteristics and performance of gas-water heat and mass transfer. The gas-water direct-contact heat transfer differential equation has been set up to obtain temperature distribution of flue gas and water. The main factors are also analyzed. In this paper, a direct-contact heat transfer model is established for a project, and the results of theoretical calculation and engineering operation are compared. The model has been verified.
引用
收藏
页码:63 / 77
页数:15
相关论文
共 50 条
  • [1] DIRECT-CONTACT HEAT-TRANSFER FOR AIR BUBBLING THROUGH WATER
    GHAZI, HS
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1991, 113 (02): : 71 - 74
  • [2] DIRECT-CONTACT HEAT-TRANSFER FOR PROCESS TECHNOLOGIES
    JACOBS, HR
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1988, 110 (4B): : 1259 - 1270
  • [3] Direct-contact condensation heat transfer on downcommerless trays for steam-water system
    Genic, SB
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (7-8) : 1225 - 1230
  • [4] EVALUATION OF HEAT-TRANSFER COEFFICIENT AT DIRECT-CONTACT CONDENSATION OF COLD WATER AND STEAM
    AYA, I
    NARIAI, H
    [J]. NUCLEAR ENGINEERING AND DESIGN, 1991, 131 (01) : 17 - 24
  • [5] DIRECT-CONTACT HEAT-TRANSFER INVOLVING A SCALING LIQUID
    MORESCO, LL
    MARSCHALL, E
    [J]. LETTERS IN HEAT AND MASS TRANSFER, 1981, 8 (04): : 337 - 340
  • [6] VOLUMETRIC HEAT-TRANSFER COEFFICIENTS FOR DIRECT-CONTACT EVAPORATION
    SMITH, RC
    ROHSENOW, WM
    KAZIMI, MS
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (02): : 264 - 270
  • [7] Heat transfer rate of direct-contact condensation on baffle trays
    Genic, Srbislav B.
    Jacimovic, Branislav M.
    Vladic, Ljubisa A.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (25-26) : 5772 - 5776
  • [8] Heat transfer in gas-liquid-liquid three-phase direct-contact exchanger
    Zhang, P
    Wang, YP
    Guo, CL
    Wang, K
    [J]. CHEMICAL ENGINEERING JOURNAL, 2001, 84 (03) : 381 - 388
  • [9] Effect of non-condensable gas on the direct-contact condensation heat transfer of vapor in a convergent tube
    Zhang, Junxia
    Li, Yang
    Zhong, Junfeng
    Wang, Zehua
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2024, 203 : 640 - 650
  • [10] Direct-contact heat transfer with change of phase: a population balance model
    Song, M
    Steiff, A
    Weinspach, PM
    [J]. CHEMICAL ENGINEERING SCIENCE, 1999, 54 (17) : 3861 - 3871