Electrochemical Determination of Trace Amounts of Lead (Ⅱ) and Cadmium (Ⅱ) at a Calix[6]arene Modified Carbon Paste Electrode

被引:0
|
作者
JI Xiao-bo
机构
关键词
lead(Ⅱ); cadmium(Ⅱ); calix\arene; differential pulse stripping voltammetry; chemically modified electrode;
D O I
暂无
中图分类号
O614 [金属元素及其化合物];
学科分类号
070301 ; 081704 ;
摘要
An electrochemical method for the simultaneous determination of lead(Ⅱ) and Cadmium(Ⅱ) with a calix\arene modified carbon paste electrode (CPE) has been developed. Pb 2+ and Cd 2+ were accumulated at the surface of the modified electrode via formation of chemical complexes with calix\arene, and reduced at 1.40 V. During the following anodic potential sweep, reduced lead and cadmium were oxidized, and two well-defined striping peaks appeared at about -0.60 V and -0.84 V. Compared with a bare carbon paste electrode, the calix\arene modified CPE greatly improves the sensitivity of determining lead and cadmium. The stripping peak currents change linearly with the concentration of Pb 2+ 3.0×10 -8 -8.0×10 -6 mol\5L -1 and with that of Cd 2+ 6.0×10 -8 -1.0×10 -5 mol\5L -1 . The detection limits of Pb 2+ and Cd 2+ are found to be 8.0×10 -9 mol\5L -1 and 2.0×10 -8 mol\5L -1 , respectively. The modified carbon paste electrode was applied to determine trace levels of lead and cadmium in water samples. Comparing with that of atomic absorption spectrometry, the results suggests that the calix\arene modified CPE has great potential for the practical sample analysis.
引用
下载
收藏
页码:943 / 948
页数:6
相关论文
共 50 条
  • [31] Effect of the p-tert-butylcalix[6]arene modifier on the electrochemical properties of the modified carbon paste electrode
    V. V. Varchenko
    K. N. Belikov
    A. B. Drapailo
    Russian Journal of Electrochemistry, 2015, 51 : 857 - 861
  • [32] Anodic Stripping Voltammetric Determination of Lead(II) Using Glassy Carbon Electrode Modified with Novel Calix[4]arene
    吕鉴泉
    何锡文
    曾宪顺
    张海丽
    张正之
    Chinese Journal of Chemistry, 2003, (06) : 687 - 692
  • [33] Effect of the p-tert-butylcalix[6]arene modifier on the electrochemical properties of the modified carbon paste electrode
    Varchenko, V. V.
    Belikov, K. N.
    Drapailo, A. B.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2015, 51 (09) : 857 - 861
  • [34] Chemically modified carbon paste electrode for the detection of lead, cadmium and zinc ions
    Koirala, Kisan
    Santos, Jose H.
    Tan, Ai Ling
    Ali, Mohammad A.
    Mirza, Aminul H.
    SENSOR REVIEW, 2016, 36 (04) : 339 - 346
  • [35] Anodic stripping voltammetric determination of lead (II) using glassy carbon electrode modified with novel calix[4]arene
    Lü, JQ
    He, XW
    Zeng, XS
    Zhang, HL
    Zhang, ZZ
    CHINESE JOURNAL OF CHEMISTRY, 2003, 21 (06) : 687 - 692
  • [36] Cadmium sensing with bentonite-modified carbon paste electrode: electrochemical insights
    Mourak, Abdellah
    Hajjaji, Mohamed
    Idoulhi, Rachid
    Khadiri, Mohy-Eddine
    Abouelfida, Abdesselam
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2023,
  • [37] Determination of trace amounts of gold(III) by cathodic stripping voltammetry using a bacteria-modified carbon paste electrode
    Hu, RZ
    Zhang, WD
    Liu, YY
    Fu, JK
    ANALYTICAL COMMUNICATIONS, 1999, 36 (04): : 147 - 148
  • [38] Silver Nanoparticle Modified Graphene Paste Electrode for the Electrochemical Detection of Lead, Cadmium and Copper
    Palisoc, Shirley
    Lee, Eldrin T.
    Natividad, Michelle
    Racines, Lotis
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (09): : 8854 - 8866
  • [39] A Calix[4]arene-tren modified electrode for determination of Lead ions in aqueous solution
    Kocer, Mustafa Baris
    Erdogan, Zehra Ozden
    Oguz, Mehmet
    Kucukkolbasi, Semahat
    Yilmaz, Mustafa
    ORGANIC COMMUNICATIONS, 2019, 12 (03) : 160 - 168
  • [40] Novel Ce-incorporated zeolite modified-carbon paste electrode for simultaneous trace electroanalysis of lead and cadmium
    Kawde, A.
    Ismail, A.
    Al-Betar, A. R.
    Muraza, O.
    MICROPOROUS AND MESOPOROUS MATERIALS, 2017, 243 : 1 - 8