Electrochemical Determination of Trace Amounts of Lead (Ⅱ) and Cadmium (Ⅱ) at a Calix[6]arene Modified Carbon Paste Electrode

被引:0
|
作者
JI Xiao-bo
机构
关键词
lead(Ⅱ); cadmium(Ⅱ); calix\arene; differential pulse stripping voltammetry; chemically modified electrode;
D O I
暂无
中图分类号
O614 [金属元素及其化合物];
学科分类号
070301 ; 081704 ;
摘要
An electrochemical method for the simultaneous determination of lead(Ⅱ) and Cadmium(Ⅱ) with a calix\arene modified carbon paste electrode (CPE) has been developed. Pb 2+ and Cd 2+ were accumulated at the surface of the modified electrode via formation of chemical complexes with calix\arene, and reduced at 1.40 V. During the following anodic potential sweep, reduced lead and cadmium were oxidized, and two well-defined striping peaks appeared at about -0.60 V and -0.84 V. Compared with a bare carbon paste electrode, the calix\arene modified CPE greatly improves the sensitivity of determining lead and cadmium. The stripping peak currents change linearly with the concentration of Pb 2+ 3.0×10 -8 -8.0×10 -6 mol\5L -1 and with that of Cd 2+ 6.0×10 -8 -1.0×10 -5 mol\5L -1 . The detection limits of Pb 2+ and Cd 2+ are found to be 8.0×10 -9 mol\5L -1 and 2.0×10 -8 mol\5L -1 , respectively. The modified carbon paste electrode was applied to determine trace levels of lead and cadmium in water samples. Comparing with that of atomic absorption spectrometry, the results suggests that the calix\arene modified CPE has great potential for the practical sample analysis.
引用
下载
收藏
页码:943 / 948
页数:6
相关论文
共 50 条
  • [21] Preparation of alizarin violet modified carbon paste electrode and its application in the voltammetric determination of trace amounts of antimony
    Xie, H.Q.
    Li, Y.H.
    Guo, H.S.
    Lihua Jianyan: Huaxue Fence/Physical Testing and Chemical Analysis Part B:Chemical Analysis, 2001, 37 (05):
  • [22] Determination of trace amounts of ochratoxin A in different food samples based on gold nanoparticles modified carbon paste electrode
    Daryoush Afzali
    Fariba Fathirad
    Sima Ghaseminezhad
    Journal of Food Science and Technology, 2016, 53 : 909 - 914
  • [23] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Huang, SS
    Cheng, YD
    Li, BF
    Liu, GD
    MIKROCHIMICA ACTA, 1998, 130 (1-2) : 97 - 101
  • [24] Determination of lead and cadmium using a polycyclodextrin-modified carbon paste electrode with anodic stripping voltammetry
    Gabriela Roa
    M. T. Ramírez-Silva
    M. A. Romero-Romo
    Laura Galicia
    Analytical and Bioanalytical Chemistry, 2003, 377 : 763 - 769
  • [25] Determination of lead and cadmium using a polycyclodextrin-modified carbon paste electrode with anodic stripping voltammetry
    Roa, G
    Ramírez-Silva, MT
    Romero-Romo, MA
    Galicia, L
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) : 763 - 769
  • [26] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Sha-Sheng Huang
    Yi-Da Cheng
    Bi-Fen Li
    Guo-Dong Liu
    Microchimica Acta, 1998, 130 : 97 - 101
  • [27] Simultaneous Anodic Stripping Voltammetric Determination of Lead and Cadmium with a Carbon Paste Electrode Modified by Tributyl Phosphate
    Huang, Sha-Sheng
    Cheng, Yi-Da
    Li, Bi-Fen
    Liu, Guo-Dong
    Mikrochimica Acta, 1998, 130 (01): : 97 - 101
  • [28] VOLTAMMETRIC DETERMINATION OF CADMIUM ON A CARBON PASTE ELECTRODE MODIFIED WITH A CHELATING RESIN
    AGRAZ, R
    SEVILLA, MT
    PINILLA, JM
    HERNANDEZ, L
    ELECTROANALYSIS, 1991, 3 (4-5) : 393 - 397
  • [29] MODIFIED CARBON-PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF TRACE SILICON
    GURENTSOVA, OI
    PROKHOROVA, GV
    OSIPOVA, EA
    JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 47 (09) : 1224 - 1228
  • [30] ELECTROCHEMICAL DETERMINATION OF SMALL AMOUNTS OF LEAD WITH USE OF A GLASSY CARBON ELECTRODE
    KABANOVA, OL
    BENIAMIN.SM
    ZHURNAL ANALITICHESKOI KHIMII, 1971, 26 (01): : 111 - +