Experimental Performance of Moderate and High Temperature Heat Pump Charged with Refrigerant Mixture BY-3

被引:0
|
作者
陈成敏 [1 ]
张于峰 [1 ]
邓娜 [1 ]
马洪亭 [1 ]
张彦所 [1 ]
马丽筠 [1 ]
胡晓微 [1 ]
机构
[1] School of Environmental Science and Engineering,Tianjin University
关键词
moderate and high temperature heat pump; refrigerant mixture; single-stage; compression heat pump system; coefficient of performance;
D O I
暂无
中图分类号
TB64 [制冷材料];
学科分类号
0805 ;
摘要
Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.
引用
收藏
页码:386 / 390
页数:5
相关论文
共 50 条
  • [21] Experimental study on the performance of a heat pump system with refrigerant mixtures' composition change
    Kim, M
    Kim, MS
    Kim, Y
    ENERGY, 2004, 29 (07) : 1053 - 1068
  • [22] Experimental performance evaluation of heat pump by using CO2 as a refrigerant
    Venkatesh, V. K.
    Basavaraju, M. G.
    Rao, K. V. Sreenivas
    INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS AND MANUFACTURING APPLICATIONS (ICONAMMA-2016), 2016, 149
  • [23] COMPARISON OF MIXTURE AND PURE REFRIGERANT HEAT-PUMP CYCLES
    WEBB, RL
    DIGIOVANNI, MA
    HEAT RECOVERY SYSTEMS & CHP, 1989, 9 (04): : 383 - 396
  • [24] Experimental Investigation and Numerical Simulation for High Temperature Air Source Heat Pump with New Mixed-Refrigerant
    Yang, Jun
    Ding, Guozhong
    Zhang, Xiaoyan
    Shu Shuiming
    Tan, Junyi
    ENGINEERING AND MANUFACTURING TECHNOLOGIES, 2014, 541-542 : 752 - +
  • [25] Experimental investigation of moderately high temperature water source heat pump with non-azeotropic refrigerant mixtures
    Zhang, Shengjun
    Wang, Huaixin
    Guo, Tao
    APPLIED ENERGY, 2010, 87 (05) : 1554 - 1561
  • [26] Experimental analysis on performance of high temperature heat pump and desiccant wheel system
    Sheng, Ying
    Zhang, Yufeng
    Deng, Na
    Fang, Lei
    Nie, Jinzhe
    Ma, Lijun
    ENERGY AND BUILDINGS, 2013, 66 : 505 - 513
  • [27] EXPERIMENTAL INVESTIGATION OF THE PERFORMANCE OF A HYDROCARBON HEAT PUMP FOR HIGH TEMPERATURE INDUSTRIAL HEATING
    Bamigbetan, O.
    Eikevik, T. M.
    Neksa, P.
    Bantle, M.
    Schlemminger, C.
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 532 - 539
  • [28] Evaluation of the impacts of high stage refrigerant charge on cascade heat pump performance
    Chae, Jung-Hoon
    Choi, Jong Min
    RENEWABLE ENERGY, 2015, 79 : 66 - 71
  • [29] Performance analysis of a modified subcritical zeotropic mixture recuperative high-temperature heat pump
    Guo, Hao
    Gong, Maoqiong
    Qin, Xiaoyu
    APPLIED ENERGY, 2019, 237 : 338 - 352
  • [30] Study of an air source heat pump with altering concentration of mixture refrigerant
    Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
    Kung Cheng Je Wu Li Hsueh Pao, 2006, 2 (202-204):