Determination of torasemide in human plasma and its bioequivalence study by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry

被引:0
|
作者
Lin Zhang [1 ]
Rulin Wang [1 ]
Yuan Tian [1 ]
Zunjian Zhang [1 ,2 ]
机构
[1] Key Laboratory of Drug Quality Control and Pharmacovigilance(Ministry of Education),China Pharmaceutical University
[2] State Key Laboratory of Natural Medicine, China Pharmaceutical University
关键词
Torasemide; HPLC–ESI–MS; Human plasma; Bioequivalence; Pharmacokinetics;
D O I
暂无
中图分类号
R927.2 [药物含量测定]; O657.63 [质谱分析];
学科分类号
070302 ; 081704 ; 1007 ;
摘要
A sensitive and selective method using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry(HPLC–ESI–MS) to determine the concentration of torasemide in human plasma samples was developed and validated. Tolbutamide was chosen as the internal standard(IS). The chromatography was performed on a Gl Sciences Inertsil ODS-3 column(100 mm*2.1 mm i.d., 5.0μm) within 5 min, using methanol with 10 mM ammonium formate(60:40, v/v) as mobile phase at a fl ow rate of 0.2 mL/min. The targeted compound was detected in negative ionization at m/z 347.00 for torasemide and 269.00 for IS. The linearity range of this method was found to be within the concentration range of 1–2500 ng/mL(r=0.9984) for torasemide in human plasma. The accuracy of this measurement was between 94.05% and 103.86%. The extracted recovery ef fi ciency was from 84.20% to 86.47% at three concentration levels. This method was also successfully applied in pharmacokinetics and bioequivalence studies in Chinese volunteers.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [1] Determination of torasemide in human plasma and its bioequivalence study by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry
    Zhang, Lin
    Wang, Rulin
    Tian, Yuan
    Zhang, Zunjian
    [J]. JOURNAL OF PHARMACEUTICAL ANALYSIS, 2016, 6 (02) : 95 - 102
  • [2] Determination of lafutidine in human plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry: application to a bioequivalence study
    Wu, LL
    Zhang, ZJ
    Tian, Y
    Li, W
    Xu, FG
    Chen, Y
    Wei, HL
    [J]. JOURNAL OF MASS SPECTROMETRY, 2005, 40 (12): : 1637 - 1643
  • [3] Determination of ritodrine in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Liu, Aixiang
    Liu, Fei
    Xu, Yu
    Xu, Fang
    Hu, Wanqun
    Guo, Qingxiang
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 867 (01): : 144 - 148
  • [4] Determination of bromazepam in human plasma by high-performance liquid chromatography with electrospray ionization tandem mass spectrometric detection: application to a bioequivalence study
    Andraus, MH
    Wong, A
    Silva, OA
    Wada, CY
    Toffleto, O
    Azevedo, CP
    Salvadori, MC
    [J]. JOURNAL OF MASS SPECTROMETRY, 2004, 39 (11): : 1348 - 1355
  • [5] Quantification of cyproheptadine in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry in a bioequivalence study
    Mendes, Gustavo Duarte
    Arruda, Andre
    Chen, Lu Shi
    de Almeida Magalhaes, Jose Cassio
    Alkharfy, Khalid M.
    De Nucci, Gilberto
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (01) : 129 - 136
  • [6] Propafenone quantification in human plasma by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry in a bioequivalence study
    Severino, Beatrice
    Luisi, Giancarlo
    Iwamoto, Renan Donomae
    Moreno, Ronilson Agnaldo
    Teixeira, Victor Perez
    Di Vaio, Paola
    Saccone, Irene
    Magli, Elisa
    Santagada, Vincenzo
    Caliendo, Giuseppe
    Mendes, Gustavo D.
    De Nucci, Gilberto
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2018, 56 (06) : 280 - 291
  • [7] Clonazepam quantification in human plasma by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry in a bioequivalence study
    Cavedal, Luiz E.
    Mendes, Fabiana D.
    Domingues, Claudia C.
    Patni, Anil K.
    Monif, Tausif
    Reyar, Simrit
    Pereira, Alberto dos S.
    Mendes, Gustavo D.
    De Nucci, Gilberto
    [J]. JOURNAL OF MASS SPECTROMETRY, 2007, 42 (01): : 81 - 88
  • [8] Determination of Tripamide in human urine by high-performance liquid chromatography and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Kim, Y
    Hwang, J
    Kim, M
    Lee, W
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (04) : 301 - 306
  • [9] Determination of imidapril and imidaprilat in human plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry
    Mabuchi, M
    Kano, Y
    Fukuyama, T
    Kondo, T
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 734 (01): : 145 - 153
  • [10] Determination of bevantolol in human plasma using liquid chromatography-electrospray ionization tandem mass spectrometry and its application to a bioequivalence study
    Ren, Li
    Wang, Zheng
    Lou, Yiceng
    Zheng, Lu
    Zheng, Heng
    Yin, Chunping
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 959 : 16 - 21