Coronary plaque response after drug eluting stent implantation assessed by serial optical coherence tomography analysis

被引:0
|
作者
TIAN FengCHEN YundaiCHEN LianSUN ZhijunLIU ChangfuGUO JunJIN Qinhua WANG Jinda and GAI Luyue Department of CardiologyChinese Peoples Liberation Army General HospitalBeijing China [100853 ]
机构
关键词
D O I
暂无
中图分类号
R816.2 [心脏血管系];
学科分类号
摘要
Background In general,percutaneous coronary intervention(PCI) relieves vessel stenosis by implantation of a stent, however,the relationship between plaque characteristics and response after stenting is not clear. Methods We enrolled 68 patients(68 vessels) with diagnosed unstable angina pectoris that prospectively underwent PCI and an optical coherence tomography(OCT) examination was done before and after stenting.Coronary plaques were classified as fibrous,lipid-rich and calcified plaque according to OCT examination,and fibrous cap thickness,lumen eccentricity,stent expansion,stent malapposition,tissue prolapse,thrombosis,dissection and stent symmetry were noted. Results The frequency of prolapse was higher in lipid-rich plaques than fibrous plaques(85%vs.40%,P<0.001). Dissection most often occurred in fibrous plaque compared with lipid-rich and calcified plaques(60%vs.32%vs.29%,P<0.001).The frequency of stent strut malapposition in calcified plaques was higher than firous and lipid-rich plaques (71%vs.40%vs.5%,P<0.001).In-stent micro-thrombosis was detected only in lipid-rich plaques,with a frequency of 37%(15/41).The risk factors of micro-thrombosis after PCI were cap thickness(OR 0.903,95%CI 0.829-0.985),lumen eccentricity(OR 1.147,95%C11.012-1.30),and stent length(OR 1.495,95%CI 1.032-2.166). Conclusion Plaque response after PCI is associated with its characteristics,and of those,micro-thrombosis after stenting in lipid-rich plaques was the most significant finding and can be predicted.
引用
收藏
页码:3752 / 3756
相关论文
共 50 条
  • [21] Effectiveness of Excimer Laser Coronary Angioplasty with Optical Coherence Tomography Guidance for In-stent Restenosis after Drug Eluting Stent Implantation
    Hashimoto, Sho
    Takahashi, Akihiko
    Yamada, Takeshi
    Mizuguchi, Yukio
    Taniguchi, Norimasa
    Nakajima, Shunsuke
    Hata, Tetsuya
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B239 - B239
  • [22] Tissue Characterization After Drug-Eluting Stent Implantation Using Optical Coherence Tomography
    Malle, Caroline
    Tada, Tomohisa
    Steigerwald, Kristin
    Ughi, Giovanni J.
    Schuster, Tibor
    Nakano, Masataka
    Massberg, Steffen
    Jehle, Johannes
    Guagliumi, Giulio
    Kastrati, Adnan
    Virmani, Renu
    Byrne, Robert A.
    Joner, Michael
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2013, 33 (06) : 1376 - +
  • [23] The predictors of neoatherosclerosis after drug-eluting stent implantation evaluated by optical coherence tomography
    Zheng, B. Z.
    Li, S. G. L.
    Chen, M. C.
    EUROPEAN HEART JOURNAL, 2018, 39 : 543 - 543
  • [24] Very late-phase vascular response after everolimus-eluting stent implantation assessed by optical coherence tomography
    Amir Kh. M. Khalifa
    Yasushi Ino
    Takashi Kubo
    Takashi Tanimoto
    Kunihiro Shimamura
    Yasutsugu Shiono
    Masahiro Takahata
    Kosei Terada
    Daisuke Higashioka
    Teruaki Wada
    Akira Taruya
    Hiroki Emori
    Yosuke Katayama
    Manabu Kashiwagi
    Akio Kuroi
    Yoshiki Matsuo
    Suwako Fujita
    Atsushi Tanaka
    Takeshi Hozumi
    Takashi Akasaka
    The International Journal of Cardiovascular Imaging, 2020, 36 : 1627 - 1635
  • [25] Very late-phase vascular response after everolimus-eluting stent implantation assessed by optical coherence tomography
    Khalifa, Amir Kh M.
    Ino, Yasushi
    Kubo, Takashi
    Tanimoto, Takashi
    Shimamura, Kunihiro
    Shiono, Yasutsugu
    Takahata, Masahiro
    Terada, Kosei
    Higashioka, Daisuke
    Wada, Teruaki
    Taruya, Akira
    Emori, Hiroki
    Katayama, Yosuke
    Kashiwagi, Manabu
    Kuroi, Akio
    Matsuo, Yoshiki
    Fujita, Suwako
    Tanaka, Atsushi
    Hozumi, Takeshi
    Akasaka, Takashi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (09): : 1627 - 1635
  • [26] Impacts of lesion angle and hinge motion on drug-eluting stent implantation assessed by optical coherence tomography
    Nakamura, S.
    Kimura, S.
    Nakagama, S.
    Hayasaka, K.
    Misawa, T.
    Mizusawa, M.
    Yamakami, Y.
    Sagawa, Y.
    Kojima, K.
    Hishikari, K.
    Sugiyama, T.
    Hikita, H.
    Takahashi, A.
    Isobe, M.
    EUROPEAN HEART JOURNAL, 2016, 37 : 866 - 866
  • [27] VASCULAR HEALING RESPONSE OF CALCIFIED CORONARY LESIONS AFTER EVEROLIMUS ELUTING STENT IMPLANTATION: EVALUATION WITH OPTICAL COHERENCE TOMOGRAPHY
    Goryo, Yutaka
    Uemura, Shiro
    Dote, Yoko
    Sugawara, Yu
    Ueda, Tomoya
    Watanabe, Makoto
    Saito, Yoshihiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1680 - A1680
  • [28] Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation
    Young-Guk Ko
    Dong-Min Kim
    Jin Man Cho
    So Yeon Choi
    Jung Han Yoon
    Jung-Sun Kim
    Byeong-Keuk Kim
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2012, 28 : 715 - 723
  • [29] Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation
    Ko, Young-Guk
    Kim, Dong-Min
    Cho, Jin Man
    Choi, So Yeon
    Yoon, Jung Han
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 715 - 723
  • [30] Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Oh, Changmyung
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 705 - 714