Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation

被引:21
|
作者
Ko, Young-Guk [1 ]
Kim, Dong-Min [1 ]
Cho, Jin Man [2 ]
Choi, So Yeon [3 ]
Yoon, Jung Han [4 ]
Kim, Jung-Sun [1 ]
Kim, Byeong-Keuk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ,5 ]
Hong, Myeong-Ki [1 ,5 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Severance Cardiovasc Ctr, Seoul 120752, South Korea
[2] Kyung Hee Univ, Coll Med, EW Neo Med Ctr, Seoul, South Korea
[3] Ajou Univ, Coll Med, Suwon 441749, South Korea
[4] Yonsei Univ, Wonju Coll Med, Wonju Christian Hosp, Wonju, South Korea
[5] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
来源
关键词
Optical coherence tomography; Stent; Thrombosis; INTRAVASCULAR ULTRASOUND FINDINGS; BARE-METAL STENTS; FOLLOW-UP; NEOINTIMAL COVERAGE; MALAPPOSITION; MECHANISMS; RESTENOSIS; PATHOLOGY; OUTCOMES; DISEASE;
D O I
10.1007/s10554-011-9905-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous optical coherence tomography (OCT) studies in patients with drug-eluting stents (DESs)-related very late stent thrombosis (VLST) were scarce. Therefore, we investigated OCT findings of VLST after implantation of DESs. Using OCT, we analyzed the status of stent struts and neointimal characteristics in 18 patients who developed VLST after DES implantation. These results were compared to those in 57 patients with neointimal hyperplasia causing > 40% diameter stenosis. Lipid-laden neointima was defined as a region with marked signal attenuation and a diffuse border. Four (22.2%) of 18 patients with VLST had ruptured and lipid-laden neointima inside DESs without uncovered or malapposed stent struts. In the remaining 14 patients who developed VLST without neointimal rupture, uncovered and malapposed struts were observed in nine and seven patients, respectively, and lipid-laden neointima in four patients. Lipid-laden neointima was more frequently observed in four patients with neointimal rupture than in 14 patients without neointimal rupture (100% vs. 28.6%, respectively, P = 0.023). Of 57 patients with neointimal hyperplasia, eight (14.0%) had lipid-laden neointima. Time to OCT study after DES implantation was significantly longer in the eight patients with lipid-laden neointima than in 49 patients without lipid-laden neointima (45.5 +/- A 17.7 months vs. 11.7 +/- A 7.2 months, respectively, P < 0.001). Lipid-laden neointima was detected in some patients with neointimal hyperplasia > 1 year after DES implantation. In addition to uncovered or malapposed struts, rupture of lipid-laden neointima inside DESs was identified in some patients with DES-related VLST.
引用
收藏
页码:715 / 723
页数:9
相关论文
共 50 条
  • [1] Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation
    Young-Guk Ko
    Dong-Min Kim
    Jin Man Cho
    So Yeon Choi
    Jung Han Yoon
    Jung-Sun Kim
    Byeong-Keuk Kim
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 715 - 723
  • [2] Mechanisms of Very Late Stent Thrombosis After Drug-Eluting Stent Implantation Findings From Coronary Angioscopy and Optical Coherence Tomography
    Ikenaga, Hiroki
    Ishihara, Masaharu
    Dai, Kazuoki
    Nakama, Yasuharu
    Ohtani, Takayuki
    [J]. JACC-CARDIOVASCULAR IMAGING, 2011, 4 (11) : 1217 - 1219
  • [3] COMPARISON OF OPTICAL COHERENCE TOMOGRAPHY FINDINGS OF VERY LATE STENT THROMBOSIS BETWEEN DRUG-ELUTING STENT AND BARE-METAL STENT
    Amioka, Michitaka
    Shiode, Nobuo
    Takahashi, Lisa
    Yamane, Kenichi
    Kawase, Tomoharu
    Yuzo, Kagawa
    Tamekiyo, Hiromichi
    Otsuka, Masaya
    Okimoto, Tomokazu
    Muraoka, Yuji
    Masaoka, Yoshiko
    Kato, Masaya
    Kihara, Yasuki
    Hayashi, Yasuhiko
    Mito, Shinji
    Dote, Keigo
    Okubo, Yousaku
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1647 - E1647
  • [4] Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence Tomography
    Taniwaki, Masanori
    Radu, Maria D.
    Zaugg, Serge
    Amabile, Nicolas
    Garcia-Garcia, Hector M.
    Yamaji, Kyohei
    Jorgensen, Erik
    Kelbaek, Henning
    Pilgrim, Thomas
    Caussin, Christophe
    Zanchin, Thomas
    Veugeois, Aurelie
    Abildgaard, Ulrik
    Jueni, Peter
    Cook, Stephane
    Koskinas, Konstantinos C.
    Windecker, Stephan
    Raeber, Lorenz
    [J]. CIRCULATION, 2016, 133 (07) : 650 - 660
  • [5] Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
    Cook, Stephane
    Wenaweser, Peter
    Togni, Mario
    Billinger, Michael
    Morger, Cyrill
    Seiler, Christian
    Vogel, Rolf
    Hess, Otto
    Meier, Bernhard
    Windecker, Stephan
    [J]. CIRCULATION, 2007, 115 (18) : 2426 - 2434
  • [6] In Vivo Optical Coherence Tomography of Very Late Drug-Eluting Stent Thrombosis Compared With Late In-Stent Restenosis
    Miyazaki, Shinichiro
    Hiasa, Yoshikazu
    Takahashi, Takefumi
    Yano, Yudai
    Minami, Tomoko
    Murakami, Naotsugu
    Mizobe, Michiko
    Tobetto, Yohei
    Nakagawa, Takafumi
    Chen, Po-Min
    Ogura, Riyo
    Miyajima, Hitoshi
    Yuba, Kenichiro
    Hosokawa, Shinobu
    Kishi, Koichi
    Ohtani, Ryuji
    [J]. CIRCULATION JOURNAL, 2012, 76 (02) : 390 - 398
  • [7] Incidence and predictors of very late Stent thrombosis after drug-eluting stent implantation
    Suh, Jon
    Lee, Seung-Whan
    Kim, Jeong-Hoon
    Park, Duk-Woo
    Lee, Jong-Young
    Kim, Young-Hak
    Lee, Cheol Whan
    Hong, Mveong-Ki
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 113L - 113L
  • [8] Very Late Stent Thrombosis 11 Years after Implantation of a Drug-Eluting Stent
    Liou, Kevin
    Jepson, Nigel
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2015, 42 (05) : 487 - 490
  • [9] Speculative Mechanisms for Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
    Nakagawa, Yoshihisa
    [J]. CIRCULATION JOURNAL, 2011, 75 (04) : 779 - 780
  • [10] The morphological findings of early and late in-stent restenosis after drug-eluting stent implantation: optical coherence tomography analysis
    Yamaguchi, H.
    Takaoka, J.
    Miyamura, A.
    Atsuchi, N.
    Shirasawa, H.
    Arikawa, R.
    Atsuchi, Y.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 747 - 747