Monte Carlo simulation of single beam dose profile

被引:0
|
作者
LIU Xiaowei
WEN Guanghao
LI Mianfeng(Zhongshan University
机构
关键词
Monte carlo simulation; Gamma knife; Dose profile;
D O I
暂无
中图分类号
TL818 [辐射剂量计];
学科分类号
082704 ;
摘要
The single beam dose profiles of Leksell Gamma Unit are simulatedand the results are compared with the experimental results of ELEKTA. The effect ofdiameter of cylinder source on the dose profile is also studied and the yielded resultsshow that there are not much difference of the dose profiles between a point sourceand cylinder source when diameter is less than 1mm.
引用
收藏
页码:87 / 90
页数:4
相关论文
共 50 条
  • [1] Monte Carlo simulation of single beam in gamma knife
    Wen, Guanghao
    Liu, Xiaowei
    Li, Mianfeng
    He Jishu/Nuclear Techniques, 2000, 23 (05): : 334 - 338
  • [2] Dose distribution for electron beam using Monte Carlo simulation with GATE
    Leste, J.
    Chauvin, M.
    Younes, T.
    Vieillevigne, L.
    Bardies, M.
    Franceries, X.
    Ferrand, R.
    Pierrat, N.
    Bartolucci, L.
    Simon, L.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S967 - S968
  • [3] Monte Carlo simulation of 10 MV photon beams and beam profile validations
    Tartar, Ahmet
    MEASUREMENT, 2013, 46 (09) : 3026 - 3031
  • [4] A MONTE-CARLO SIMULATION FOR NEUTRAL BEAM PROBING OF PLASMA CURRENT PROFILE
    MASAMUNE, S
    OKADA, H
    YAMAGIWA, M
    OKAMOTO, M
    NISHIHARA, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1982, 21 (11): : L693 - L695
  • [5] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Weiss, DE
    Johnson, WC
    Kensek, RP
    RADIATION PHYSICS AND CHEMISTRY, 1997, 50 (05): : 475 - 485
  • [6] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Corp. Res. Proc. Technol. Laboratory, 3M Company, 3M Center, St. Paul, MN 55144-1000, United States
    不详
    不详
    Radiat. Phys. Chem., 5 (475-485):
  • [7] On the commissioning of Monte Carlo beam models and dose profile corrections on stereotactic photon beams
    Papaconstadopoulos, P.
    Tessier, F.
    Syme, A.
    Seuntjens., J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S107 - S108
  • [8] Unbiased Monte Carlo simulation of the compton profile
    Fernandez, J. E.
    Scot, V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 209 - 213
  • [9] Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation
    Mohammadi, Gh R. Fallah
    Hesamnezhad, L.
    Mahdavi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (04): : 813 - 818
  • [10] Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations
    Morant, J. J.
    Salvado, M.
    Casanovas, R.
    Hernandez-Giron, I.
    Velasco, E.
    Calzado, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (03): : 200 - 209