Evaluation of a Novel Mechanical Compression Device

被引:0
|
作者
Davis, Carmen R. [1 ]
Beeson, Terrie [1 ]
Porter, Haley M. [1 ]
Giuliano, Karen K. [2 ,3 ]
机构
[1] Indiana Univ Hlth Univ Hosp, Indianapolis, IN 46202 USA
[2] Univ Massachusetts, Amherst Inst Appl Life Sci, Amherst, MA USA
[3] Elaine Marieb Ctr Nursing & Engn Innovat, Amherst, MA USA
关键词
evidence-based practice; mechanical compression device; patient mobility; quality improvement; venous thromboembolism; VTE prophylaxis; VENOUS THROMBOEMBOLISM; PREVENTION; THERAPY;
D O I
10.1097/01.NAJ.0001081748.24595.eb
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background: Venous thromboembolism (VTE) is a leading preventable cause of death in hospitalized patients. Current intermittent pneumatic compression (IPC) devices used to provide external mechanical compression for VTE prevention are associated with a multitude of clinical challenges that often result in subtherapeutic use. A comparative study was conducted of the real-world clinical use of a novel mechanical compression device (MCD) and a current IPC device. Purpose: The purpose of this quality improvement project was to compare use of the novel MCD and the standard IPC device on three clinical inpatient hospital units. Comparisons were based on the following patient outcome measures: evaluation of wear time, adherence to optimal wear time, evaluation of both patient comfort and device satisfaction, and perceived impact on mobility goals. Nurses' satisfaction with the clinical usability for mobility was also measured. Methods: This project used a pre-post design. A convenience sample of 89 surgical patients on the three clinical study units and 63 nursing staff members were recruited for the study. Data were collected using electronic health records, MCD data records, patient surveys, and nursing staff surveys. Data were analyzed using descriptive statistics and independent sample t tests. In the preintervention period, data were collected using the current IPC device. Nursing staff were then trained on use of the MCD. In the postintervention period, the MCDs were used in place of the IPC devices. Results: MCD patients had significantly longer (P <= 0.001) wear time (mean, 19.3 hours/day) compared with IPC patients (mean, 12.9 hours/day). MCD patients also reported significantly better sleep (P = 0.04), fewer problems with sweaty legs (P <= 0.001), and improved assistance with mobility goals (P <= 0.001) than IPC patients. Nursing staff reported significantly improved accuracy of mobility documentation (P <= 0.001) with the MCD, but no differences in their perception of patient satisfaction with meeting mobility goals. Conclusions: Use of the MCD device for VTE prophylaxis resulted in actual and perceived improvements from the perspective of both patients and nurses. While these results provide initial data in support of a potentially promising system, more research is needed.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 50 条
  • [31] Mechanical chest compression with the LifeLine ARM device during simulated CPR
    Truszewski, Zenon
    Szarpak, Lukasz
    Kurowski, Andrzej
    Evrin, Togay
    Madziala, Marcin
    Czyzewski, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (05): : 917 - 917
  • [32] Pseudoaneurysm of femoral artery following catheterization: Treatment by mechanical compression device
    Chatterjee, T
    Do, DD
    Mahler, F
    CIRCULATION, 1997, 96 (08) : 3484 - 3484
  • [33] ANASTOMOTIC COMPRESSION BUTTON - A NEW MECHANICAL DEVICE FOR SUTURELESS BOWEL ANASTOMOSIS
    MALTHANER, RA
    HAKKI, FZ
    SAINI, N
    ANDREWS, BL
    HARMON, JW
    DISEASES OF THE COLON & RECTUM, 1990, 33 (04) : 291 - 297
  • [34] Evaluation of a novel device that maintains the balance of a cardiopulmonary resuscitation performer in a moving ambulance to improve chest compression quality
    Feng, Shun Yi
    Song, Ya Qi
    Zhang, Yu Lin
    Li, Yong
    SINGAPORE MEDICAL JOURNAL, 2013, 54 (11) : 645 - 648
  • [35] TRANSTHORACIC ECHOCARDIOGRAPHY DURING CARDIAC ARREST WITH A MECHANICAL CHEST COMPRESSION DEVICE
    Campbell, Douglas
    Perman, Sarah
    Wilson, Juliana
    CRITICAL CARE MEDICINE, 2020, 48
  • [36] Pericardial laceration after using an automated mechanical chest compression device
    Ondruschka, B.
    Hartwig, T.
    Gries, A.
    Haedrich, C.
    Dressler, J.
    Bernhard, M.
    NOTFALL & RETTUNGSMEDIZIN, 2017, 20 (05): : 424 - 429
  • [37] Evaluation of a Novel Wearable Non-Pneumatic Compression Device for the Treatment of Breast Cancer-Related Lymphedema
    Julia Rodrick
    Heather Barnhart
    Stanley G. Rockson
    Thomas Maldonado
    Biomedical Materials & Devices, 2025, 3 (1): : 586 - 592
  • [38] Evaluation of a novel EEG preamplifier device
    Grant, AC
    O'Halloran, JP
    Gerhard, CB
    Chung, SS
    NEUROLOGY, 2002, 58 (07) : A450 - A450
  • [39] STANDARDIZATION FOR NOVEL RADIOFREQUENCY DEVICE EVALUATION
    DiBernardo, Barry E.
    McDaniel, David H.
    LASERS IN SURGERY AND MEDICINE, 2019, 51 : S33 - S33