Evaluation of a Novel Mechanical Compression Device

被引:0
|
作者
Davis, Carmen R. [1 ]
Beeson, Terrie [1 ]
Porter, Haley M. [1 ]
Giuliano, Karen K. [2 ,3 ]
机构
[1] Indiana Univ Hlth Univ Hosp, Indianapolis, IN 46202 USA
[2] Univ Massachusetts, Amherst Inst Appl Life Sci, Amherst, MA USA
[3] Elaine Marieb Ctr Nursing & Engn Innovat, Amherst, MA USA
关键词
evidence-based practice; mechanical compression device; patient mobility; quality improvement; venous thromboembolism; VTE prophylaxis; VENOUS THROMBOEMBOLISM; PREVENTION; THERAPY;
D O I
10.1097/01.NAJ.0001081748.24595.eb
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background: Venous thromboembolism (VTE) is a leading preventable cause of death in hospitalized patients. Current intermittent pneumatic compression (IPC) devices used to provide external mechanical compression for VTE prevention are associated with a multitude of clinical challenges that often result in subtherapeutic use. A comparative study was conducted of the real-world clinical use of a novel mechanical compression device (MCD) and a current IPC device. Purpose: The purpose of this quality improvement project was to compare use of the novel MCD and the standard IPC device on three clinical inpatient hospital units. Comparisons were based on the following patient outcome measures: evaluation of wear time, adherence to optimal wear time, evaluation of both patient comfort and device satisfaction, and perceived impact on mobility goals. Nurses' satisfaction with the clinical usability for mobility was also measured. Methods: This project used a pre-post design. A convenience sample of 89 surgical patients on the three clinical study units and 63 nursing staff members were recruited for the study. Data were collected using electronic health records, MCD data records, patient surveys, and nursing staff surveys. Data were analyzed using descriptive statistics and independent sample t tests. In the preintervention period, data were collected using the current IPC device. Nursing staff were then trained on use of the MCD. In the postintervention period, the MCDs were used in place of the IPC devices. Results: MCD patients had significantly longer (P <= 0.001) wear time (mean, 19.3 hours/day) compared with IPC patients (mean, 12.9 hours/day). MCD patients also reported significantly better sleep (P = 0.04), fewer problems with sweaty legs (P <= 0.001), and improved assistance with mobility goals (P <= 0.001) than IPC patients. Nursing staff reported significantly improved accuracy of mobility documentation (P <= 0.001) with the MCD, but no differences in their perception of patient satisfaction with meeting mobility goals. Conclusions: Use of the MCD device for VTE prophylaxis resulted in actual and perceived improvements from the perspective of both patients and nurses. While these results provide initial data in support of a potentially promising system, more research is needed.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 50 条
  • [21] A novel hypothesis for exercise hyperemia: Mechanical compression
    Jasperse, JL
    Kluess, HA
    Hamann, JJ
    Buckwalter, JB
    Clifford, PS
    CIRCULATION, 2005, 112 (17) : U267 - U267
  • [22] EVALUATION OF A COMPRESSION INTRAOSSEOUS FIXATION DEVICE IN MANDIBULAR FRACTURES
    BOYNE, PJ
    MORGAN, FH
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1972, 33 (05): : 696 - &
  • [23] Manual compression in comparison to a mechanical compression device (FemoStop®) after diagnostic and/or interventional coronary angiography
    Stiebellehner, L
    Nikfardjan, M
    Diem, K
    Atteneder, M
    Stulnig, T
    Priglinger, U
    Gottsauner-Wolf, M
    Huber, K
    WIENER KLINISCHE WOCHENSCHRIFT, 2002, 114 (19-20) : 847 - 852
  • [24] Back Plate Marking of a Mechanical Chest Compression Device to Reduce the Duration of Chest Compression Interruptions
    Khunpanich, Sireethorn
    Pethyabarn, Wasuntaraporn
    OPEN ACCESS EMERGENCY MEDICINE, 2022, 14 : 405 - 412
  • [25] Novel Mechanical Occlusion Device for Transcervical Sterilization
    Rehan, M.
    Coleman, J. E.
    Olabi, A. G.
    WORLD CONGRESS ON ENGINEERING, WCE 2010, VOL I, 2010, : 566 - 571
  • [26] A pilot study of venous flow augmentation using a novel mechanical graded intermittent sequential compression device for venous insufficiency
    Wall, James
    Johnson, Eric
    Johnson, Bonnie
    Singh, Anup
    Shaheen, Raymond
    Fogarty, Thomas
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2019, 7 (02) : 217 - 221
  • [27] HISTOLOGICAL AND MECHANICAL EVALUATION OF THE LIGAMENT AUGMENTATION DEVICE
    MENDENHALL, HV
    MCPHERSON, GK
    GIBBONS, DF
    PLENK, H
    ROTTMANN, W
    SANFORD, JB
    KENNEDY, JC
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1983, 29 : 314 - 317
  • [28] Monitoring mechanical impedance of the thorax with compression and decompression cardiopulmonary resuscitation device
    Seong Min Kang
    Seong Wook Choi
    Journal of Mechanical Science and Technology, 2019, 33 : 981 - 988
  • [29] AUTOMATIC MECHANICAL DEVICE TO STANDARDIZE ACTIVE COMPRESSION-DECOMPRESSION CPR
    WENZEL, V
    FUERST, RS
    IDRIS, AH
    BANNER, MJ
    RUSH, WJ
    ORBAN, DJ
    ANNALS OF EMERGENCY MEDICINE, 1995, 25 (03) : 386 - 389
  • [30] Monitoring mechanical impedance of the thorax with compression and decompression cardiopulmonary resuscitation device
    Kang, Seong Min
    Choi, Seong Wook
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2019, 33 (02) : 981 - 988