Experimental and GEANT4 simulated FEPE of NaI(Tl) detector for linear sources

被引:0
|
作者
Mansoor, Shahid [1 ,2 ]
Malik, Azhar Hussain [1 ]
Satti, Khizar Hayat [2 ,3 ]
Ijaz, Misbah [4 ]
Siddique, Muhammad Tariq [3 ]
机构
[1] Pakistan Inst Engn & Appl Sci PIEAS, Dept Nucl Engn DNE, Islamabad, Pakistan
[2] Pakistan Inst Nucl Sci & Technol PINSTECH, Hlth Phys Div HPD, PO Nilore, Islamabad, Pakistan
[3] Pakistan Inst Engn & Appl Sci PIEAS, Dept Phys & Appl Math DPAM, Islamabad, Pakistan
[4] Quaid I Azam Univ, Dept Math, Islamabad, Pakistan
来源
关键词
NaI(Tl) scintillation detector; Tc-99m line source; full energy peak efficiency (FEPE); Monte Carlo (MC) GEANT4 simulations; MONTE-CARLO-SIMULATION; CIRCULAR DETECTOR; NAI DETECTOR; EFFICIENCY; MCNP;
D O I
10.1088/2057-1976/adaec8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using Tc-99m solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.7 cm. The FEPE is measured for the fabricated linear source using 2 '' x2 '' NaI(Tl) cylindrical detector at various source-detector distances. The experimental setup is simulated in GEANT4 and the computed FEPE values are compared with experimental values. The absolute error of 5% is observed between computed and measured FEPE values. Utilizing the advantages of MC simulations, the impact of numerous source parameters such as source length, diameter, source-detector distance, glass tube thickness and lead shield effects on FEPE are investigated to optimize the fabrication process of linear sources. A case study for current investigation has been analyzed by considering absolute FEPE of the NaI(Tl) system for a syringe filled with radioactive solution. This study provides an insight for the fabrication of standard linear sources by analyzing different source parameters and hence, may serve as a guideline to prepare standard linear sources for the calibration of radiation detectors.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] STOCHASTIC SIMULATION STUDY OF HPGe DETECTOR RESPONSE AND THE EFFECT OF DETECTOR AGING USING GEANT4
    Tariq, Hina
    Mirza, Sikander M.
    Rehman, Shakeel Ur
    Mirza, Nasir M.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2017, 32 (01): : 57 - 69
  • [42] Experimental verification of proton transport at gracing incidence in GEANT4
    Kimstrand, P.
    Traneus, E.
    Tilly, N.
    Ahnesjoe, A.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S81 - S82
  • [43] Experimental quantification of Geant4 PhysicsList recommendations: methods and results
    Basaglia, Tullio
    Han, Min Cheol
    Hoff, Gabriela
    Kim, Chan Hyeong
    Kim, Sung Hun
    Pia, Maria Grazia
    Saracco, Paolo
    21ST INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP2015), PARTS 1-9, 2015, 664
  • [44] Experimental and Geant4 Simulation Study of MURA Mask for Scintimammography
    Alnafea, Mohammed A.
    Shamma, Khaled
    Kadri, Omrane
    APPLIED SCIENCES-BASEL, 2022, 12 (10):
  • [45] Irradiation of 4" x 4" NaI(Tl) detector by the 14 MeV neutrons
    Sudac, D.
    Valkovic, V.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 896 - 900
  • [46] The use of Geant4 for simulations of a plastic β-detector and its application to efficiency calibration
    Golovko, V. V.
    Iacob, V. E.
    Hardy, J. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (02): : 266 - 272
  • [47] Wurtzite Gallium Nitride as a scintillator detector for alpha particles (a Geant4 simulation)
    Taheri, A.
    Sheidaiy, M.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [48] Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4
    Giubrone, G.
    Ortiz, J.
    Gallardo, S.
    Martorell, S.
    Bas, M. C.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 158 : 114 - 118
  • [49] Intrinsic time resolution and efficiency study for simulated scintillators plastics with Geant4
    Quintos, E. Marquez
    Fernandez, C. H. Zepeda
    Rebolledo-Herrera, L. F.
    Barbosa, E. Moreno
    REVISTA MEXICANA DE FISICA, 2023, 69 (04)
  • [50] Investigation of neutron scattering in the Multi-Blade detector with Geant4 simulations
    Galgoczi, G.
    Kanaki, K.
    Piscitelli, F.
    Kittelmann, T.
    Varga, D.
    Hall-Wilton, R.
    JOURNAL OF INSTRUMENTATION, 2018, 13