Computed tomography image quality in patients with primary hepatocellular carcinoma: intraindividual comparison of contrast agent concentrations

被引:0
|
作者
Peng, Fei [1 ]
Luo, Chaotian [1 ]
Ning, Xiaojing [1 ]
Xiao, Fangyan [1 ]
Guan, Kaiming [1 ]
Tang, Cheng [1 ]
Huang, Fuling [1 ]
Liang, Junli [1 ]
Peng, Peng [1 ]
机构
[1] Guangxi Med Univ, Dept Radiol, Affiliated Hosp 1, Nanning, Peoples R China
基金
中国国家自然科学基金;
关键词
contrast agent; iodine concentration; hepatocellular carcinoma; comparative study; computed tomography; IODINE CONCENTRATIONS; ENHANCEMENT; MEDIA; LIVER; CT; ANGIOGRAPHY;
D O I
10.3389/fmed.2024.1460505
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aimed to assess the impact of the different concentrations of iodine contrast agents used on the quality of computed tomography (CT) images obtained intraindividually in hepatocellular carcinoma patients. Methods: In this retrospective study, data from a cohort of 29 patients diagnosed with primary hepatocellular carcinoma who had undergone two preoperative CT-enhanced examinations within a 3-month timeframe were analyzed. Each patient was randomly assigned to receive either a low-concentration contrast agent (300 mg I/mL iohexol) or a high-concentration contrast agent (350 mg I/mL iohexol) for the first scan and the alternative contrast agent for the second scan. CT images of different liver regions of each patient were compared between low-and high-concentration scans using their before-and-after control design. Subjective image quality scores for portal vein images were also assessed. Results: The findings of this study indicate that patients in the high-concentration group presented significantly elevated CT values across various anatomical regions, including the liver parenchyma, abdominal aorta, and hepatic portal vein, compared to those in the low-concentration group (p < 0.05). Moreover, the high-concentration group demonstrated superior subjective image ratings (p < 0.05). Nevertheless, there was no statistically significant difference in the CT values observed in liver cancer parenchyma scans at different phases between the two groups (p > 0.05). Conclusion: In summary, using a high-concentration iodine contrast agent is efficient in enhancing the visual clarity of the liver parenchyma, the aorta, and the portal vein in individuals diagnosed with primary hepatocellular carcinoma.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] COMPARISON OF DOSIMETRY AND IMAGE QUALITY IN COMPUTED AND CONVENTIONAL TOMOGRAPHY
    MAUEDICKSON, W
    TREFLER, M
    DICKSON, DR
    RADIOLOGY, 1979, 131 (02) : 509 - 514
  • [22] Growth rate of primary single hepatocellular carcinoma - Determining optimal screening interval with contrast enhanced computed tomography
    Kubota, K
    Ina, H
    Okada, Y
    Irie, T
    DIGESTIVE DISEASES AND SCIENCES, 2003, 48 (03) : 581 - 586
  • [23] ADOPTION OF COMPUTED TOMOGRAPHY IMAGE GUIDANCE AMONG HEPATOCELLULAR CARCINOMA PATIENTS WITH PERCUTANEOUS RADIOFREQUENCY ABLATION
    Huo, J.
    Chung, T. H.
    Aloia, T. A.
    Sheu, T.
    Shih, Y. T.
    VALUE IN HEALTH, 2016, 19 (03) : A136 - A136
  • [24] COMPARISON OF COMPUTED TOMOGRAPHY IMAGE QUALITY USING INTRAVENOUS VS. INTRAOSSEOUS CONTRAST ADMINISTRATION IN SWINE
    Cohen, Jason
    Duncan, Luke
    Triner, Wayne
    Rea, Jeffrey
    Siskin, Gary
    King, Christopher
    JOURNAL OF EMERGENCY MEDICINE, 2015, 49 (05): : 771 - 777
  • [25] Different Intravenous Contrast Media Concentrations Do Not Affect Clinical Assessment of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Scans in an Intraindividual Comparison
    Prechtel, Hans W. E.
    Verburg, Frederik A.
    Palmowski, Moritz
    Krohn, Thomas
    Pietsch, Hubertus
    Kuhl, Christiane K.
    Mottaghy, Felix M.
    Behrendt, Florian F.
    INVESTIGATIVE RADIOLOGY, 2012, 47 (09) : 497 - 502
  • [26] Enhancement pattern of hepatocellular carcinoma: comparison of real-time contrast-enhanced ultrasound and contrast-enhanced computed tomography
    Liu, Guang-Jian
    Xu, Hui-Xiong
    Lu, Ming-De
    Xie, Xiao-Yan
    Xu, Zuo-Feng
    Zheng, Yan-Ling
    Liang, Jin-Yu
    CLINICAL IMAGING, 2006, 30 (05) : 315 - 321
  • [27] Evaluation of recurrence in gastric carcinoma: Comparison of contrast-enhanced computed tomography and positron emission tomography/computed tomography
    Kim, Jong Hyeon
    Heo, Suk Hee
    Kim, Jin Woong
    Shin, Sang Soo
    Min, Jung Jun
    Kwon, Seong Young
    Jeong, Yong Yeon
    Kang, Heoung Keun
    WORLD JOURNAL OF GASTROENTEROLOGY, 2017, 23 (35) : 6448 - 6456
  • [28] Contrast-Enhanced High-Pitch Computed Tomography in Pediatric Patients Without Electrocardiography Triggering and Sedation: Comparison of Cardiac Image Quality With Conventional Multidetector Computed Tomography
    Esser, Michael
    Gatidis, Sergios
    Teufel, Matthias
    Ketelsen, Ines
    Nikolaou, Konstantin
    Schaefer, Juergen F.
    Tsiflikas, Ilias
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (01) : 165 - 171
  • [29] Evaluation of recurrence in gastric carcinoma: Comparison of contrast-enhanced computed tomography and positron emission tomography/computed tomography
    Jong Hyeon Kim
    Suk Hee Heo
    Jin Woong Kim
    Sang Soo Shin
    Jung Jun Min
    Seong Young Kwon
    Yong Yeon Jeong
    Heoung Keun Kang
    World Journal of Gastroenterology, 2017, (35) : 6448 - 6456
  • [30] A comparison of the use of contrast media with different iodine concentrations for enhanced computed tomography
    Du, Yu
    Wang, Ya-Ning
    Wang, Qi
    Qi, Xiao-Hui
    Shi, Gao-Feng
    Jia, Li-Tao
    Wang, Xiang-Ming
    Shi, Jia-Bao
    Liu, Feng-Yun
    Wang, Li-Jia
    Liu, Xiang
    FRONTIERS IN PHYSIOLOGY, 2023, 14