Prospective Comparison of Clinical Outcomes After Bilateral Implantation of Diffractive Trifocal Extended Depth-of-Focus and Diffractive Trifocal Hydrophobic Intraocular Lenses

被引:0
|
作者
Nagy, Zoltan Z. [1 ]
Dorman, Peter [1 ]
Szalczer, Szilard [1 ]
Kiss, Huba [1 ]
机构
[1] Semmelweis Univ, Dept Ophthalmol, Maria Utca 39, H-1085 Budapest, Hungary
关键词
PATIENT SATISFACTION; REFRACTIVE OUTCOMES; VISUAL OUTCOMES; PERFORMANCE; IOLS; ORTHOKERATOLOGY; QUALITY; DESIGN; LASIK;
D O I
10.3928/1081597X-20241113-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare clinical outcomes for patients implanted with either FineVision HP or FineVision Triumf intraocular lenses (IOL) (Beaver-Visitec International, Inc) following cataract surgery. METHODS: Twenty-six patients bilaterally implanted with the HP IOL and 27 patients with the Triumf IOL were followed up for 6 months in a prospective randomized study. Refraction, uncorrected and corrected distance visual acuity (CDVA), uncorrected and distance-corrected intermediate visual acuity (DCIVA), and uncorrected and distance-corrected near visual acuity (DCNVA) were evaluated. Defocus curves and contrast sensitivity were also measured. Patient-reported outcomes were assessed using the National Eye Institute Visual Function Questionnaire 25, and adverse events were registered. RESULTS: Ninety-four percent of the eyes in both groups were within +/- 1.00 diopter (D) of spherical equivalent. All of the patients had 20/20 or better binocular CDVA in both groups and 96% and 100% had 20/25 or better binocular CDIVA in the Triumf and HP IOL groups, respectively, being reduced to 32% and 91.7% for DCNVA, respectively. Differences between groups were statistically significant from-2.00 to-4.50 D with better visual acuity outcomes for the HP IOL group (P < .01). Better monocular photopic contrast sensitivity was found for the Triumf IOL group at 12 and 18 cycles per degree (P < .01). There was a statistically significant increase of the overall composite score in both groups before and after surgery (P < .001). Spectacle independence was similar between groups for distance and intermediate vision but higher for the HP IOL for near vision (96% versus 75%). There were no adverse events related to the IOLs. CONCLUSIONS: Both IOLs showed good and comparable distance and intermediate visual acuities but near vision was better for the HP IOL. This model provided higher spectacle independence for near vision.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Comparison of the Visual Outcomes of an Extended Depth-of-Focus Lens and a Trifocal Lens
    Moshirfar, Majid
    Ellis, James
    Beesley, Daniel
    McCabe, Shannon E.
    Lewis, Adam
    Jnr, William B. West
    Ronquillo, Yasmyne
    Snr, Phillip Hoopes
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 3051 - 3063
  • [42] Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics
    Sakisaka, Toshihiro
    Minami, Keiichiro
    Takada, Keita
    Mori, Yosai
    Miyata, Kazunori
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [43] Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics
    Toshihiro Sakisaka
    Keiichiro Minami
    Keita Takada
    Yosai Mori
    Kazunori Miyata
    BMC Ophthalmology, 21
  • [44] Comparison of the Visual Outcomes after Cataract Surgery with Implantation of a Bifocal and Trifocal Diffractive Intraocular Lens
    Yu, Sung
    Kim, Yong Il
    Ha, Sang Won
    Lee, Gwang Ja
    Lee, Kyoo Won
    Park, Young Jeung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (03): : 405 - 412
  • [45] Contrast Sensitivity and Patient Reported Outcomes After Bilateral Implantation of a Bi-Aspheric Hydrophobic Trifocal Diffractive Intraocular Lens
    Tana-Rivero, Pedro
    Orts-Vila, Paz
    Aguilar-Corcoles, Salvador
    Tana-Sanz, Pedro
    Tana-Sanz, Santiago
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 247 - 258
  • [46] Comparison of Objective and Subjective Visual Outcomes Between Pentafocal and Trifocal Diffractive Intraocular Lenses
    Bellucci, Carlo
    Mora, Paolo
    Tedesco, Salvatore Antonio
    Gandolfi, Stefano
    Bellucci, Roberto
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (09)
  • [47] Tolerance to decentration of biaspheric intraocular lenses with refractive phase-ring extended depth of focus and diffractive trifocal designs
    Cervino, Alejandro
    Esteve-Taboada, Jose Juan
    Chiu, Yi-Feng
    Yang, Chuan-Hui
    Tseng, Wen-Chu
    Lee, William
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (08) : 2541 - 2550
  • [48] Comparison of visual outcomes after two types of mix-and-match implanted trifocal extended-depth-of-focus and trifocal intraocular lenses
    Kim, Jung Wan
    Eom, Youngsub
    Park, Wonkyung
    Song, Jong Suk
    Jeong, Ji Won
    Park, Seh Kwang
    Kim, Hyo Myung
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (10) : 3275 - 3283
  • [49] The Postoperative Visual and Refractive Outcomes of Trifocal and Extended Depth-of-Focus Intraocular Lenses in Patients with Different Biometric Characteristics
    Lee, Chia-Yi
    Chen, Hung-Chi
    Lian, Ie-Bin
    Huang, Jing-Yang
    Yang, Shun-Fa
    Chang, Chao-Kai
    DIAGNOSTICS, 2024, 14 (16)
  • [50] Comparative numerical analysis of astigmatism tolerance in bifocal, extended depth-of-focus, and trifocal intraocular lenses
    You, Jongin
    Jang, Mooseok
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (02): : 628 - 642