Protective biomechanical and histological changes in the false lumen wall in chronic type B aortic dissection

被引:0
|
作者
Dong, Hai [1 ,2 ]
Liu, Minliang [3 ,4 ]
Cebull, Hannah L. [5 ]
Chhabra, Arshiya [2 ]
Zhou, Yumeng [2 ]
Piccinelli, Marina [5 ]
Oshinski, John N. [5 ]
Elefteriades, John A. [3 ,4 ,6 ]
Gleason, Rudolph L. [2 ]
Leshnower, Bradley G. [1 ]
机构
[1] Emory Univ, Sch Med, Div Cardiothorac Surg, Carlyle Fraser Cardiothorac Res Lab, 1365 Clifton Rd,Suite A 2213, Atlanta, GA 30322 USA
[2] Emory Univ, Sch Med, Dept Radiol & Imaging Sci, Atlanta, GA 30322 USA
[3] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA USA
[4] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA USA
[5] Texas Tech Univ, Dept Mech Engn, Lubbock, TX USA
[6] Yale Univ, Yale New Haven Hosp, Aort Inst, Div Cardiac Surg,Sch Med, New Haven, CT USA
来源
JTCVS OPEN | 2025年 / 23卷
基金
美国国家卫生研究院;
关键词
aortic dissection; false lumen wall; biomechanical stiffness; histological analysis; COLLAGEN-FIBERS; THORACIC AORTA; ANEURYSM;
D O I
10.1016/j.xjon.2024.11.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The outer false lumen wall (FLW) changes from thin/compliant to thick/ rigid as aortic dissection transitions from the acute to chronic phase. This study investigates biomechanical stiffness and histological changes of the FLW as the dissected aorta ages. Methods: The free outer FLW from human tissue was analyzed from chronic type B dissection (chronic-FLW) n = 10, acute type A dissection (acute-FLW) n = 10, and transplant donor descending aorta that was manually peeled into 2 layers (controlFLW) n = 17. Biaxial tension testing in the longitudinal and circumferential directions was performed and stress-strain curves were obtained. A lower and higher tangent modulus was determined to assess stiffness. Quantification of collagen and elastin was performed by calculating the fibers' volume fraction from Z-stack scans. Results: The higher tangent modulus of chronic-FLW is larger (P < .01) than the acute-FLW and control-FLW in longitudinal (5.09 +/- 0.9 MPa vs 1.72 +/- 0.56 MPa and 1.17 +/- 0.22 MPa) and circumferential (4.16 +/- 0.67 MPa vs 1.04 +/- 0.24 MPa and 1.07 +/- 0.16 MPa) directions. The lower tangent modulus of chronic-FLW is larger (P <.05) than acute-FLW and control-FLW in both directions (longitudinal: 0.72 +/- 0.24 MPa vs 0.13 +/- 0.02 MPa and 0.27 +/- 0.03 MPa circumferential:0.44 +/- 0.13 MPa vs 0.12 +/- 0.01 MPa and 0.21 +/- 0.02 MPa). The volume fraction of collagen was increased (P <.01) and the volume fraction of elastin was decreased (P <.001) when comparing chronic-FLW, acute-FLW, and controlFLW (collagen-volume fraction: 0.24 +/- 0.03 vs 0.12 +/- 0.03 and 0.08 +/- 0.02; elastinvolume fraction: 0.09 +/- 0.03 vs 0.28 +/- 0.03 and 0.39 +/- 0.04). Conclusions: As the acutely dissected aorta transitions to the chronic phase, the FL remodels by increasing collagen, decreasing elastin, and increasing aortic stiffness and thickness. This change in the chronic-FLW may be a protective adaptation to prevent FL enlargement and rupture in type B aortic dissection.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 50 条
  • [31] Percutaneous renal denervation through a false lumen fenestration in aortic dissection type B
    Ewen, S.
    Mahfoud, F.
    Boehm, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 1133 - 1133
  • [32] Intercostal artery embolization to induce false lumen thrombosis in type B aortic dissection
    Magee, Gregory A.
    Yi, Jeniann A.
    Kuwayama, David P.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2020, 6 (03): : 433 - 437
  • [33] Influence of tear configuration on false and true lumen haemodynamics in type B aortic dissection
    Rudenick, Paula A.
    Bordone, Maurizio
    Bijnens, Bart H.
    Soudah, Eduardo
    Onate, Eugenio
    Garcia-Dorado, David
    Evangelista, Arturo
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 2509 - 2512
  • [34] Left atrial collapse due to a giant false lumen in type B aortic dissection
    Rodolfo San Antonio
    Eduardo Josué Flores Umanzor
    Paula Sánchez Somonte
    Guillem Caldentey
    Intensive Care Medicine, 2017, 43 : 133 - 134
  • [35] Left atrial collapse due to a giant false lumen in type B aortic dissection
    San Antonio, Rodolfo
    Flores Umanzor, Eduardo Josue
    Sanchez Somonte, Paula
    Caldentey, Guillem
    INTENSIVE CARE MEDICINE, 2017, 43 (01) : 133 - 134
  • [36] The Prevalence of Sleep Apnea in Type B Aortic Dissection: Implications for False Lumen Thrombosis
    Wang, Ling
    Chen, Jiyan
    Li, Guangxi
    Luo, Songyuan
    Wang, Rui
    Li, Wei
    Zhang, Jiawei
    Liu, Yuan
    Huang, Wenhui
    Cao, Yingshu
    Zhou, Yingling
    Chen, Pingyan
    Pressman, Gregg S.
    Somers, Virend K.
    Luo, Jianfang
    SLEEP, 2017, 40 (03)
  • [37] Successful Endovascular Correction of an Endograft Connected with the False Lumen of a Type B Aortic Dissection
    Delclaux, Nicolas
    Sobocinski, Jonathan
    Maurel, Blandine
    Le Roux, Marielle
    Tyrrell, Mark R.
    Azzaoui, Richard
    Haulon, Stephan
    ANNALS OF VASCULAR SURGERY, 2014, 28 (08) : 1935.e7 - 1935.e11
  • [38] Acute type A aortic dissection and the consequences of a patent false lumen
    White, Abigail
    Bozso, Sabin J.
    Ouzounian, Maral
    Chu, Michael W. A.
    Moon, Michael C.
    JTCVS TECHNIQUES, 2021, 9 : 1 - 8
  • [39] Inducing false lumen thrombosis for retrograde type A aortic dissection
    Zhang, Rongjie
    Zhou, Jian
    Feng, Jiaxuan
    Zhao, Zhiqing
    Liu, Junjun
    Li, Zhenjiang
    Feng, Rui
    Jing, Zaiping
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (01): : 57 - 65
  • [40] Predictors for outcome in type A aortic dissection: A focus on false lumen
    Santamaria, Valeria
    Schirone, Leonardo
    Vinciguerra, Mattia
    De Bellis, Antonio
    Greco, Ernesto
    CIRUGIA CARDIOVASCULAR, 2021, 28 (02): : 71 - 76