Predictors for outcome in type A aortic dissection: A focus on false lumen

被引:1
|
作者
Santamaria, Valeria [1 ]
Schirone, Leonardo [2 ]
Vinciguerra, Mattia [1 ]
De Bellis, Antonio [3 ]
Greco, Ernesto [1 ]
机构
[1] Sapienza Univ Rome, Dept Clin Internal Med Anesthesiol & Cardiovasc S, Rome, Italy
[2] Sapienza Univ Rome, Dept Med Surg Sci & Biotechnol, Latina, Italy
[3] Casa Cura S Michele, Dept Cardiol & Cardiac Surg, Maddaloni, Caserta, Italy
来源
CIRUGIA CARDIOVASCULAR | 2021年 / 28卷 / 02期
关键词
Acute Type A aortic dissection; Pre-operative outcome predictors; False lumen status;
D O I
10.1016/j.circv.2020.10.010
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Acute type A aortic dissection (AAD) is a life-threatening emergency in cardiac surgery, with high in-hospital (22%) and long-term morbidity and mortality rates. Methods: Data from 134 patients were collected from anamnesis and computed tomography before and after aortic surgery. Data were analyzed using IBM SPSS v23. Results: We found that male patients had better survival than the female (p < 0.01) and that age is associated with increased perioperative death (p < 0.001). Similarly, patients admitted in shock (p < 0.001) and undergoing longer extracorporeal circulation (p < 0.05) were associated with lower survival. We observed that patients admitted with partial thrombosis of false lumen had increased survival compared to those presenting a patent lumen (p < 0.001). Also, we compared the mortality of the different surgical procedures and found that no intervention had a significant association with increased survival (p > 0.05). Among survived patients, we found that an increased pre-operative ascending aorta diameter is associated with the establishment of a chronic partial thrombosis (54.2 +/- 4.6 vs 50.5 +/- 7.0 mm, p < 0.05). Moreover, increased pre-operative descending aorta diameter is associated with a longer complete thrombosis time (29.2 +/- 6.1 vs 37.2 +/- 6.9 mm, p < 0.05). Conclusions: We found that, in our experience, there is no significant difference between the most commonly used surgical procedures. However, we found that age, gender, shock, pre-operative lumen patency and CEC time are important predictors of survival. Moreover, we found that pre-operative aortic diameters are dramatically relevant to determine the time for a complete thrombosis of the false lumen. (C) 2020 Sociedad Espanola de Cirugia Cardiovascular y Endovascular. Published by Elsevier Espana, S.L.U.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [1] Predictors of false lumen thrombosis in type B aortic dissection treated with TEVAR
    Tolenaar, Jip L.
    Kern, John A.
    Jonker, Frederik H. W.
    Cherry, Kenneth J.
    Tracci, Megan C.
    Angle, John F.
    Sabri, Saher
    Trimarchi, Santi
    Strider, David
    Alaiwaidi, Gorav
    Upchurch, Gilbert R., Jr.
    ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (03) : 255 - 263
  • [2] False lumen patency as a predictor of late outcome in aortic dissection
    Bernard, Y
    Zimmermann, H
    Chocron, S
    Litzler, JF
    Kastler, B
    Etievent, JP
    Meneveau, N
    Schiele, F
    Bassand, JP
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (12): : 1378 - 1382
  • [3] Acute type A aortic dissection and the consequences of a patent false lumen
    White, Abigail
    Bozso, Sabin J.
    Ouzounian, Maral
    Chu, Michael W. A.
    Moon, Michael C.
    JTCVS TECHNIQUES, 2021, 9 : 1 - 8
  • [4] Inducing false lumen thrombosis for retrograde type A aortic dissection
    Zhang, Rongjie
    Zhou, Jian
    Feng, Jiaxuan
    Zhao, Zhiqing
    Liu, Junjun
    Li, Zhenjiang
    Feng, Rui
    Jing, Zaiping
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (01): : 57 - 65
  • [5] Computational analysis to predict false-lumen perfusion and outcome of type B aortic dissection
    D'Ancona, Giuseppe
    Lee, Jake Jaesang
    Pasta, Salvatore
    Pilato, Gerlando
    Rinaudo, Antonino
    Follis, Fabrizio
    Pilato, Michele
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (04): : 1756 - 1758
  • [6] Aortic Arch False Lumen Embolisation in a Residual Chronic Type A Aortic Dissection
    Pellenc, Quentin
    Castier, Yves
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (04) : 600 - 601
  • [7] Aortic Diameter, True Lumen, and False Lumen Growth Rates in Chronic Type B Aortic Dissection
    Blount, Kevin J.
    Hagspiel, Klaus D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05) : W222 - W229
  • [8] A Case Report of Type B Aortic Dissection With Ruptured False Lumen
    Suthar, Pokhraj P.
    Hussein, Mohamed Z.
    Gaddikeri, Ramya
    Shah, Palmi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [9] Factors Affecting False Lumen Thrombosis In Type B Aortic Dissection
    Tang, Qian-hui
    Chen, Jing
    Yang, Han
    Qin, Zhong
    Lin, Qiu-ning
    Qin, Xiao
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2023, 120 (08)
  • [10] Coil Embolization of the False Lumen in Complicated Type B Aortic Dissection
    Hussain, Mohamad A.
    Lindsay, Thomas F.
    Tan, Kong T.
    Moloney, Tony
    ANNALS OF VASCULAR SURGERY, 2015, 29 (01)