Online Diagnosis of Short-Circuit Faults of Permanent Magnet Synchronous Generator by Short-Time Analysis of the Three Phase Amplitude-Phase Signal Based on Analytical Modeling

被引:0
|
作者
Tabarniarami, Zabihollah [1 ]
Ghods, Mehrage [1 ]
Faiz, Jawad [1 ]
Abedini, Moein [1 ]
机构
[1] Univ Tehran, Coll Engn, Sch Elect & Comp Engn, Tehran 1449957131, Iran
关键词
advanced signal processing; alpha beta o frame; energy; equivalent magnetic network (EMN); phase-to-phase short circuit (PPSC); permanent magnet syn- chronous machine (PMSM); short-time analysis of the amplitude-phase signal (ST-APS); turn to-turn short circuit (TTSC); STATOR; PMSM; MACHINES; VOLTAGE; FIELD;
D O I
10.1109/TTE.2024.3369970
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Turn-to-turn short-circuit (TTSC) fault is one of the most common faults in electric machines and may destroy coil insulation and demagnetize the magnets. In addition to the TTSC fault, this paper also introduces and analyzes the phase-to-phase short-circuit (PPSC) fault, which can have even more destructive effects than the TTSC fault. The analytical equivalent magnetic network (EMN) method is used to accurately model the healthy and faulty machine with a shorter processing time than the finite element method (FEM). The output current of the generator in the $\alpha \beta $ frame is employed to detect the faults. The mathematical equations demonstrate the change in amplitude and phase of the signals under fault conditions. Therefore, the short-time analysis of the amplitude-phase signal (ST-APS) method is presented, and the fault index is obtained by extracting real-time amplitude and phase. In addition, the proposed method separates TTSC and PPSC faults. Finally, FEM and EMN modeling results are compared with the experimental results for the prototype permanent magnet synchronous machine (PMSM). The results showed that the proposed EMN method combined with ST-APS achieves a high accuracy and enables fault detection in various stages, regardless of changes in generator speed or transient conditions. Furthermore, the proposed fault detection method is unaffected by various nonlinear loads or winding configurations, ensuring high reliability.
引用
收藏
页码:10029 / 10042
页数:14
相关论文
共 50 条
  • [31] Direction Criterion for Phase-to-phase Short-circuit Faults in Distribution Networks with Photovoltaic Based on Negative-sequence Current Amplitude
    Mu, Rui
    He, Jiawei
    Li, Bin
    Zhou, Bohao
    Zhang, Yongwu
    Huang, Jiakai
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2024, 48 (19): : 148 - 161
  • [32] Analysis of the DC side sudden short circuit of three-phase/twelve-phase synchronous generator system
    Li, YX
    Wang, XH
    Wang, SM
    Su, PS
    Ma, WM
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 903 - 908
  • [33] Demagnetization Analysis of Axial Flux Permanent Magnet Motor under Three Phase Short Circuit Fault
    Bahador, Nooshin
    Darabi, Ahmad
    Hasanabadi, Hasan
    4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), 2013, : 333 - 337
  • [34] Application of Frequency Response Analysis Method to Detect Short-Circuit Faults in Three-Phase Induction Motors
    Al-Ameri, Salem Mgammal
    Alawady, Ahmed Allawy
    Yousof, Mohd Fairouz Mohd
    Kamarudin, Muhammad Saufi
    Salem, Ali Ahmed
    Abu-Siada, Ahmed
    Mosaad, Mohamed I.
    APPLIED SCIENCES-BASEL, 2022, 12 (04):
  • [35] Analysis and fault-tolerant control of inter-turn short-circuit fault for five-phase permanent-magnet synchronous machine
    Zheng, Zaiping
    Li, Qiqi
    Li, Xuyang
    Zheng, Ping
    Wang, Kaichun
    Cui, Peijuan
    ENERGY REPORTS, 2022, 8 : 7360 - 7373
  • [36] Fault-Tolerant Control of Coil Inter-Turn Short-Circuit in Five-Phase Permanent Magnet Synchronous Motor
    Wang, Dingyu
    Chen, Yiguang
    ENERGIES, 2020, 13 (21)
  • [37] Analysis of Three-Phase Short-Circuit in Winding of Armature of Turbo-Generator with Dual Winding for Each Phase.
    Fjalkowski, Zbigniew
    Szymanski, Andrzej
    Archiwum Elektrotechniki, 1986, 35 (01): : 143 - 167
  • [38] Estimation of field-winding electromagnetic parameters of a synchronous generator through sudden three-phase short-circuit tests
    Larin, A. M.
    Tkachenko, A. A.
    Larina, I. I.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2005, (02) : 32 - +
  • [39] Incipient Interturn Short-Circuit Fault Diagnosis of Permanent Magnet Synchronous Motors Based on the Data-Driven Digital Twin Model
    Chen, Zhichao
    Liang, Deliang
    Jia, Shaofeng
    Yang, Lin
    Yang, Shuzhou
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (03) : 3514 - 3524
  • [40] Short-Circuit Fault Diagnosis for Three-Phase Inverters Based on Voltage-Space Patterns
    Alavi, Marjan
    Wang, Danwei
    Luo, Ming
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (10) : 5558 - 5569