关键词
advanced signal processing; alpha beta o frame; energy; equivalent magnetic network (EMN); phase-to-phase short circuit (PPSC); permanent magnet syn- chronous machine (PMSM); short-time analysis of the amplitude-phase signal (ST-APS); turn to-turn short circuit (TTSC); STATOR; PMSM; MACHINES; VOLTAGE; FIELD;
D O I
10.1109/TTE.2024.3369970
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Turn-to-turn short-circuit (TTSC) fault is one of the most common faults in electric machines and may destroy coil insulation and demagnetize the magnets. In addition to the TTSC fault, this paper also introduces and analyzes the phase-to-phase short-circuit (PPSC) fault, which can have even more destructive effects than the TTSC fault. The analytical equivalent magnetic network (EMN) method is used to accurately model the healthy and faulty machine with a shorter processing time than the finite element method (FEM). The output current of the generator in the $\alpha \beta $ frame is employed to detect the faults. The mathematical equations demonstrate the change in amplitude and phase of the signals under fault conditions. Therefore, the short-time analysis of the amplitude-phase signal (ST-APS) method is presented, and the fault index is obtained by extracting real-time amplitude and phase. In addition, the proposed method separates TTSC and PPSC faults. Finally, FEM and EMN modeling results are compared with the experimental results for the prototype permanent magnet synchronous machine (PMSM). The results showed that the proposed EMN method combined with ST-APS achieves a high accuracy and enables fault detection in various stages, regardless of changes in generator speed or transient conditions. Furthermore, the proposed fault detection method is unaffected by various nonlinear loads or winding configurations, ensuring high reliability.
引用
收藏
页码:10029 / 10042
页数:14
相关论文
共 50 条
  • [21] Diagnosis of Interturn Short-Circuit Faults in Permanent Magnet Synchronous Motors Based on Few-Shot Learning Under a Federated Learning Framework
    Zhang, Jinglin
    Wang, Yanbo
    Zhu, Kai
    Zhang, Yi
    Li, Yuanjiang
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2021, 17 (12) : 8495 - 8504
  • [22] Optimum fault-tolerant control of multi-phase permanent magnet machines for open-circuit and short-circuit faults
    Dwari, Suman
    Parsa, Leila
    APEC 2007: TWENTY-SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 2007, : 1417 - +
  • [23] Analysis of three-phase short-circuit current characteristics of doubly fed induction generator
    Fan X.
    Sun S.
    Sun D.
    Hai S.
    Wang Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (18): : 38 - 48
  • [24] Diagnosis of Short-Circuit Fault in Large-Scale Permanent-Magnet Wind Power Generator Based on CMAC
    Hsieh, Chin-Tsung
    Yau, Her-Terng
    Shiu, Jen
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2013, 2013
  • [25] Interturn Short-Circuit Fault Diagnosis of Interior Permanent Magnet Synchronous Motor for Electric Vehicle Based on Search Coil
    Huang, Wan
    Du, Bochao
    Li, Tiannan
    Sun, Yousu
    Cheng, Yuan
    Cui, Shumei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (02) : 2506 - 2515
  • [26] Mitigation of Interturn Short Circuit Fault Based on Axial Split Phase Permanent Magnet Synchronous Machine
    Geng, Lina
    Chai, Feng
    Pei, Yulong
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (04) : 2578 - 2587
  • [27] An innovative MRAS-based technique for online detection of short-circuit faults in three-phase induction motor windings
    Milles, Abdessmad
    Benbouhenni, Habib
    Debdouche, Naamane
    Yessef, Mourad
    Elbarbary, Z. M. S.
    ELECTRICAL ENGINEERING, 2024, : 5269 - 5290
  • [28] Online detection method for inter-turn short-circuit fault of permanent magnet synchronous motor based on deep learning
    Shi, Chengji
    Lu, Xiaojuan
    2020 6TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, PTS 1-5, 2020, 546
  • [29] Disturbance-Observer-Based Direct Torque Control of Five-Phase Permanent Magnet Motor Under Open-Circuit and Short-Circuit Faults
    Zhou, Huawei
    Xu, Jinhui
    Chen, Cheng
    Tian, Xiange
    Liu, Guohai
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (12) : 11907 - 11917
  • [30] Modeling of Inter-Turn and Inter-Phase Short-Circuit of Flux-Switching Permanent Magnet Motors
    Li, Guang-Jin
    Zhu, Zi-Qiang
    Gabsi, Mohamed
    Griffo, Antonio
    Ojeda, Javier
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 6476 - 6483