Enhancing seafood processing wastewater treatment efficiency of an Anaerobic Membrane Bioreactor (AnMBR) system: a comparison of post-treatment methods

被引:0
|
作者
Luu, Tran Le [1 ]
Duy, Ho Nguyen Anh [1 ]
Hang, Tran Thi Thai [1 ]
Nguyet, Phan Nhu [2 ]
Thanh, Bui Xuan [3 ,4 ]
Tuyen, Nguyen Van [5 ]
Thuan, Tran Hung [5 ]
Quang, Chu Xuan [5 ]
机构
[1] Vietnamese German Univ, Master program Water Technol Reuse & Management, Ben Cat, Binh Duong, Vietnam
[2] Vietnam Natl Univ Ho Chi Minh City, Univ Sci, Fac Environm, Ho Chi Minh City, Vietnam
[3] Ho Chi Minh City Univ Technol HCMUT, 268 Ly Thuong Kiet St, Ho Chi Minh City, Vietnam
[4] Vietnam Natl Univ Ho Chi Minh City VNU HCM, Ho Chi Minh City 700000, Vietnam
[5] Natl Ctr Technol Progress, Ctr Adv Mat & Environm Technol, Hanoi, Vietnam
来源
GLOBAL NEST JOURNAL | 2024年 / 26卷 / 09期
关键词
Post treatment; seafood processing wastewater; anaerobic membrane bioreactor; chlorine; polyaluminium chloride; granular activated carbon; ADSORPTION; REMOVAL;
D O I
10.30955/gnj.06376
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An Anaerobic membrane bioreactor (AnMBR) was applied for treating wastewater of a seafood processing factory in Vietnam. However, Chemical Oxygen Demand (COD), Total Phosphorus (TP), and Total Nitrogen (TN) values of the AnMBR effluent were 250.43 mg/l, 19.96 mg/l, and 62.65 mg/l, respectively, and were about two times higher than the technical regulation for seafood processing wastewater in Vietnam. AnMBR needs to be combined with other posttreatment processes to ensure that treated water can meet the technical regulation. Therefore, current research has tested various advanced post-treatment methods for AnMBR effluent including chlorine, poly aluminum chloride (PAC) combined with anionic polymer, and granular activated carbon (GAC). Different concentrations of the above chemicals and reaction times were tested to select the appropriate post-treatment method. The results showed that chlorine had the lowest treatment efficiency for all four parameters (Total suspended solids -TSS, COD, TP, and TN). GAC was more effective than PAC in treatment of TN and TSS. Besides, GAC with a concentration of 5000 mg/L and a reaction time of 60 minutes brought the highest TSS, COD, TP, and TN treatment efficiency with 94.04, 79.11; 86.19, and 71.23%. This implies that GAC is the suitable method for the post-treatment of AnMBR seafood processing effluent.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Treatment of pharmaceutical wastewater containing β-lactams antibiotics by a pilot-scale anaerobic membrane bioreactor (AnMBR)
    Huang, Bin
    Wang, Hong-Cheng
    Cui, Dan
    Zhang, Bo
    Chen, Zhao-Bo
    Wang, Ai-Jie
    CHEMICAL ENGINEERING JOURNAL, 2018, 341 : 238 - 247
  • [22] Novel anaerobic membrane bioreactor (AnMBR) design for wastewater treatment at long HRT and high solid concentration
    Berkessa, Yifru Waktole
    Yan, Binghua
    Li, Tengfei
    Tan, Ming
    She, Zonglian
    Jegatheesan, Veeriah
    Jiang, Heqing
    Zhang, Yang
    BIORESOURCE TECHNOLOGY, 2018, 250 : 281 - 289
  • [23] Post-treatment options for the anaerobic treatment of domestic wastewater
    Chernicharo C.A.L.
    Reviews in Environmental Science and Bio/Technology, 2006, 5 (1) : 73 - 92
  • [24] Wastewater Treatment by Anaerobic Fluidized Membrane Bioreactor
    Karadag, Dogan
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2019, 28 (05): : 3551 - 3568
  • [25] Wastewater treatment in a submerged anaerobic membrane bioreactor
    Casu, Stefania
    Crispino, Nedda A.
    Farina, Roberto
    Mattioli, Davide
    Ferraris, Marco
    Spagni, Alessandro
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2012, 47 (02): : 204 - 209
  • [26] Treatment of anaerobic membrane bioreactor (AnMBR) effluent using direct contact membrane distillation
    Chen, Lin
    Liu, Chang
    Cao, Chuqing
    Zhu, Liang
    DESALINATION AND WATER TREATMENT, 2017, 65 : 89 - 97
  • [27] Improving organic and nutrient removal efficiencies in seafood processing wastewater using anaerobic membrane bioreactor (AnMBR) integrates with anoxic/oxic (AO) processes
    Hang, Tran Thi Thai
    Phat, Vien Vinh
    Hanh, Huynh Hieu
    Luu, Tran Le
    Thuan, Tran Hung
    Tuyen, Nguyen Van
    Quang, Chu Xuan
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 954
  • [28] Anaerobic membrane bioreactor (AnMBR) with external ultrafiltration membrane for the treatment of sugar beet vinasse
    Bueno, Beatriz Egerland
    Muniz Brito, Andre Luiz
    Rea, Victor. S. Garcia
    Kurnianto, Rifki Wahyu
    Zaiat, Marcelo
    van Lier, Jules. B.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [29] The use of anaerobic membrane bioreactor and reverse osmosis system for wastewater treatment
    Zgavarogea, Ramona
    Covaliu, Cristina
    Iordache, Andreea
    Niculescu, Violeta
    Neacsa, Marin
    UPB Scientific Bulletin, Series B: Chemistry and Materials Science, 2017, 79 (02): : 55 - 62
  • [30] Evaluation of a sponge assisted-granular anaerobic membrane bioreactor (SG-AnMBR) for municipal wastewater treatment
    Chen, C.
    Guo, W. S.
    Ngo, H. H.
    Liu, Y.
    Du, B.
    Wei, Q.
    Wei, D.
    Nguyen, D. D.
    Chang, S. W.
    RENEWABLE ENERGY, 2017, 111 : 620 - 627