Two-Dimensional Liquid Chromatography-Isotope Ratio Mass Spectrometry Opens New Possibilities in the Field of Compound-Specific Stable Isotope Analysis

被引:0
|
作者
Rockel, Sarah P. [1 ,2 ]
Marks, Robert G. H. [1 ]
Kerpen, Klaus [1 ,2 ]
Jochmann, Maik A. [1 ,2 ]
Schmidt, Torsten C. [1 ,2 ]
机构
[1] Univ Duisburg Essen, Instrumental Analyt Chem, D-45141 Essen, Germany
[2] Univ Duisburg Essen, Ctr Water & Environm Res ZWU, D-45141 Essen, Germany
关键词
OF-THE-ART; TEMPERATURE; CAFFEINE; SCIENCE;
D O I
10.1021/acs.analchem.4c05956
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Compound-specific stable isotope analysis (CSIA) using liquid chromatography-isotope ratio mass spectrometry (LC-IRMS) is a powerful tool for determining the isotopic composition of carbon in analytes from complex mixtures. However, LC-IRMS methods are constrained to fully aqueous eluents. Previous efforts to overcome this limitation were unsuccessful, as the use of organic eluents in LC-IRMS was deemed impossible. In our study, we developed a two-dimensional (2D) LC-IRMS method that, for the first time, enables the use of organic-containing eluents in an LC-IRMS setting. Initial experiments with caffeine were performed using a sample loop modulator with 20% methanol in the mobile phase of the first dimension, while separating the organic fraction from the analyte in the second dimension. Comparing results with one-dimensional (1D) LC-IRMS methods showed high precision with delta 13C values in 2D measurements (-34.98 +/- 0.04 parts per thousand) closely matching 1D results (-34.95 +/- 0.12 parts per thousand). In the next step, incorporation of an at-column dilution (ACD) modulator allowed for the successful use of methanol concentrations up to 40% in the first dimension, with the ACD modulator effectively mitigating both peak fronting and carbon background interference, without losing any precision or accuracy of the measurements (delta 13CCaffeine = -34.92 +/- 0.03 parts per thousand). All developed methods showed a method detection limit lower than 5 mg of carbon L-1 (mgC L-1), which is a major improvement compared with previous studies on caffeine analysis with LC-IRMS. This proof-of-concept study on 2D-LC-IRMS opens vast new possibilities for future CSIA research across diverse fields, including environmental science, pharmaceuticals, and food chemistry.
引用
收藏
页码:2991 / 2997
页数:7
相关论文
共 50 条
  • [41] A versatile method for simultaneous stable carbon isotope analysis of DNA and RNA nucleotides by liquid chromatography/isotope ratio mass spectrometry
    Moerdijk-Poortvliet, Tanja C. W.
    Brasser, Jurian
    de Ruiter, Gerjan
    Houtekamer, Marco
    Bolhuis, Henk
    Stal, Lucas J.
    Boschker, Henricus T. S.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (12) : 1401 - 1411
  • [42] A versatile method for stable carbon isotope analysis of carbohydrates by high-performance liquid chromatography/isotope ratio mass spectrometry
    Boschker, H. T. S.
    Moerdijk-Poortvliet, T. C. W.
    van Breugel, P.
    Houtekamer, M.
    Middelburg, J. J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (23) : 3902 - 3908
  • [43] Compound-Specific Stable Isotope Analysis: Implications in Hexachlorocyclohexane in-vitro and Field Assessment
    Puneet Kohli
    Hans H. Richnow
    Rup Lal
    Indian Journal of Microbiology, 2017, 57 : 11 - 22
  • [44] Analysis of Compound-Specific Chlorine Stable Isotopes of Vinyl Chloride by Continuous Flow-Isotope Ratio Mass Spectrometry (FC-IRMS)
    Shouakar-Stash, Orfan
    Frape, S. K.
    Aravena, R.
    Gargini, A.
    Pasini, M.
    Drimmie, R. J.
    ENVIRONMENTAL FORENSICS, 2009, 10 (04) : 299 - 306
  • [45] Compound-Specific Stable Isotope Analysis: Implications in Hexachlorocyclohexane in-vitro and Field Assessment
    Kohli, Puneet
    Richnow, Hans H.
    Lal, Rup
    INDIAN JOURNAL OF MICROBIOLOGY, 2017, 57 (01) : 11 - 22
  • [46] Substantial peak size effect on compound-specific δD values analyzed on isotope ratio mass spectrometry
    Liu, Hu
    Cao, Yunning
    Hu, Jing
    Liu, Zhonghui
    Liu, Weiguo
    CHEMICAL GEOLOGY, 2022, 590
  • [47] Bulk and compound-specific stable isotope ratio analysis for authenticity testing of organically grown tomatoes
    Bontempo, Luana
    van Leeuwen, Katryna A.
    Paolini, Mauro
    Laursen, Kristian Holst
    Micheloni, Cristina
    Prenzler, Paul D.
    Ryan, Danielle
    Camin, Federica
    FOOD CHEMISTRY, 2020, 318
  • [48] Separation of PAHs in aerosol by thin layer chromatography for compound-specific stable carbon isotope analysis
    Liu, XH
    Bi, XH
    Mai, BX
    Sheng, GY
    Fu, JM
    TALANTA, 2005, 66 (02) : 487 - 494
  • [49] Highlighting the Effects of Co-eluting Interferences on Compound-Specific Stable Isotope Analysis of Polycyclic Aromatic Hydrocarbons by Using Comprehensive Two-Dimensional Gas Chromatography
    Gauchotte-Lindsay, Caroline
    McGregor, Laura A.
    Assal, Antoine
    Thomas, Russell
    Kalin, Robert M.
    CHEMPLUSCHEM, 2014, 79 (06): : 804 - 812
  • [50] Stable Carbon Isotope Analysis of Hexachlorocyclohexanes by Liquid-Liquid Extraction Gas Chromatography Isotope Ratio Mass Spectrometry: Method Evaluation and Applications
    Gao, Cuiping
    Wang, Yunlong
    Xia, Yu
    Liu, Haixian
    Cheng, Weiguo
    Xie, Yi
    Yang, Yuesuo
    MOLECULES, 2022, 27 (09):