Analysis of the safety and efficacy of flow diverter device in the treatment of tandem aneurysms in the internal carotid artery

被引:0
|
作者
Wan, Jun [1 ,2 ]
Xu, Ligang [2 ]
Jiang, Yeqing [3 ]
Zhang, Lei [2 ]
Wang, Zhenyu [2 ]
Zhang, Xiaolong [3 ]
Wang, Shengzhang [1 ,4 ]
机构
[1] Fudan Univ, Acad Engn & Technol, Shanghai, Peoples R China
[2] Fudan Univ, Jingan Dist Cent Hosp, Dept Intervent Radiol, Shanghai, Peoples R China
[3] Fudan Univ, Dept Radiol, Huashan Hosp, Shanghai, Peoples R China
[4] Fudan Univ, Inst Biomech, Dept Aeronaut & Astronaut, Shanghai, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2025年 / 16卷
关键词
intracranial aneurysms; tandem aneurysms; flow diverter device; pipeline; Tubridge; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT;
D O I
10.3389/fneur.2025.1462108
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective To investigate the clinical efficacy and safety of flow diverter device (FDD) in the treatment of tandem aneurysms in the internal carotid artery. Materials and methods This study was a retrospectively observational study involving two neurointerventional centers. Sixteen Patients with tandem aneurysms in the internal carotid artery treated with FDD and Digital Subtraction Angiography (DSA) follow-up in Huashan Hospital Affiliated with Fudan University and Jing'an District Central Hospital Affiliated with Fudan University from 2020.08 to 2023.12 were included. The outcomes included the angiographic occlusion rate of aneurysms, complications, and the modified Rankin Scale score. The risk factors of complete occlusion of tandem aneurysms were explored by logistic regression analysis. Results A total of 38 aneurysms were included, including 21 aneurysms of 8 patients in the Pipeline Embolization Device (PED) group and 17 aneurysms of 8 patients in the Tubridge Flow Diverter (TFD) group. A total of 16 FDD stents were implanted, 8 in each PED and TFD group, with a technical success rate of 100%. The median value of maximum aneurysm diameter (D-max) was 4.27 (3.57-5.41) mm. Among them, 28 aneurysms had a maximum diameter of <5 mm (73.7%), 10 aneurysms had a maximum diameter of 5-15 mm (26.3%). All patients were followed up clinically for a median of 25.5 months (15.5-28.7 months). There were no deaths and symptomatic complications. The modified Rankin Scale scores (mRS) of 16 patients were all less than 2. All patients were examined by angiography with a median of 14 months (6-27 months). Among them, there were 5 Consensus Grading Scale for Endovascular Aneurysm Occlusion (CGSFEAO) grade 5 (13.2%), 1 CGSFEAO grade 4 (2.6%), 1 CGSFEAO grade 2 (2.6%) and 31 CGSFEAO grade 0 (81.6%). The complete occlusion rate of intracranial aneurysm in the whole study was 81.6%, including 85.7% in the PED group and 76.5% in the TFD group, and there was no significant statistical difference between the two groups. Statistically significant variables were not found in univariate logistic regression analysis. Conclusion FDD is safe and effective in treating tandem aneurysms in the internal carotid artery with a high occlusion rate and few complications. TFD is comparable to PED in the treatment of intracranial tandem aneurysms.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Tortuosity of parent artery predicts in-stent stenosis after pipeline flow-diverter stenting for internal carotid artery aneurysms
    Gao, Haibin
    You, Wei
    Wei, Dachao
    Lv, Jian
    Sun, Wei
    Li, Youxiang
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [42] Patency of the posterior communicating artery after flow diversion treatment of internal carotid artery aneurysms
    Brinjikji, Waleed
    Lanzino, Giuseppe
    Cloft, Harry J.
    Kallmes, David F.
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 120 : 84 - 88
  • [43] Effectiveness of Derivo® Flow Diverter Device in the Endovascular Treatment of Cerebrovascular Aneurysms
    Coban, Mustafa Kemal
    Ulku, Goktug
    Sahin, Mustafa Caglar
    Unal, Cansu
    Okay, Hilmi Onder
    TURKISH NEUROSURGERY, 2023, 33 (04) : 591 - 595
  • [44] Treatment of Traumatic Internal Carotid Artery Aneurysm by Flow-Diverter: A Single-Center Experience
    Dogan, Adem
    Durmaz, Mehmet Ozan
    Yuce, Gokhan
    Ezgu, Mehmet Can
    NEUROCHIRURGIE, 2022, 68 (06) : E60 - E67
  • [45] Fracture of a Flow Diverter in the Cervical Internal Carotid Artery Due to Eagle Syndrome
    Pfaff, Johannes A. R.
    Weymayr, Friedrich
    Killer-Oberpflazer, Monika
    NEUROINTERVENTION, 2023, 18 (01) : 72 - 75
  • [46] Surgical treatment of giant internal carotid artery aneurysms
    Mizoi, K
    Kinouchi, H
    Takahashi, A
    Yoshimoto, T
    DEVELOPMENTS IN NEUROSCIENCE, PROCEEDINGS, 2002, 1247 : 75 - 84
  • [47] Endovascular Treatment of Supraclinoid Internal Carotid Artery Aneurysms
    Patel, Biraj M.
    Ahmed, Azam
    Niemann, David
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2014, 25 (03) : 425 - +
  • [48] Flow diverter stents for endovascular treatment of aneurysms: a comparative study of efficacy and safety between FREDX and FRED
    Guimaraens, Leopoldo
    Saldana, Jesus
    Vivas, Elio
    Cifuentes, Sebastian
    Balaguer, Ernest
    Mon, Dunia
    Macias-Gomez, Adria
    Ois, Angel
    Guisado-Alonso, Daniel
    Cuadrado-Godia, Elisa
    Jimenez-Balado, Joan
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024,
  • [50] DIAGNOSIS AND TREATMENT OF INTERNAL CAROTID-ARTERY ANEURYSMS
    MCINTEE, RA
    DANIELS, HA
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1987, 97 (02) : 195 - 195