Analysis of the safety and efficacy of flow diverter device in the treatment of tandem aneurysms in the internal carotid artery

被引:0
|
作者
Wan, Jun [1 ,2 ]
Xu, Ligang [2 ]
Jiang, Yeqing [3 ]
Zhang, Lei [2 ]
Wang, Zhenyu [2 ]
Zhang, Xiaolong [3 ]
Wang, Shengzhang [1 ,4 ]
机构
[1] Fudan Univ, Acad Engn & Technol, Shanghai, Peoples R China
[2] Fudan Univ, Jingan Dist Cent Hosp, Dept Intervent Radiol, Shanghai, Peoples R China
[3] Fudan Univ, Dept Radiol, Huashan Hosp, Shanghai, Peoples R China
[4] Fudan Univ, Inst Biomech, Dept Aeronaut & Astronaut, Shanghai, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2025年 / 16卷
关键词
intracranial aneurysms; tandem aneurysms; flow diverter device; pipeline; Tubridge; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT;
D O I
10.3389/fneur.2025.1462108
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective To investigate the clinical efficacy and safety of flow diverter device (FDD) in the treatment of tandem aneurysms in the internal carotid artery. Materials and methods This study was a retrospectively observational study involving two neurointerventional centers. Sixteen Patients with tandem aneurysms in the internal carotid artery treated with FDD and Digital Subtraction Angiography (DSA) follow-up in Huashan Hospital Affiliated with Fudan University and Jing'an District Central Hospital Affiliated with Fudan University from 2020.08 to 2023.12 were included. The outcomes included the angiographic occlusion rate of aneurysms, complications, and the modified Rankin Scale score. The risk factors of complete occlusion of tandem aneurysms were explored by logistic regression analysis. Results A total of 38 aneurysms were included, including 21 aneurysms of 8 patients in the Pipeline Embolization Device (PED) group and 17 aneurysms of 8 patients in the Tubridge Flow Diverter (TFD) group. A total of 16 FDD stents were implanted, 8 in each PED and TFD group, with a technical success rate of 100%. The median value of maximum aneurysm diameter (D-max) was 4.27 (3.57-5.41) mm. Among them, 28 aneurysms had a maximum diameter of <5 mm (73.7%), 10 aneurysms had a maximum diameter of 5-15 mm (26.3%). All patients were followed up clinically for a median of 25.5 months (15.5-28.7 months). There were no deaths and symptomatic complications. The modified Rankin Scale scores (mRS) of 16 patients were all less than 2. All patients were examined by angiography with a median of 14 months (6-27 months). Among them, there were 5 Consensus Grading Scale for Endovascular Aneurysm Occlusion (CGSFEAO) grade 5 (13.2%), 1 CGSFEAO grade 4 (2.6%), 1 CGSFEAO grade 2 (2.6%) and 31 CGSFEAO grade 0 (81.6%). The complete occlusion rate of intracranial aneurysm in the whole study was 81.6%, including 85.7% in the PED group and 76.5% in the TFD group, and there was no significant statistical difference between the two groups. Statistically significant variables were not found in univariate logistic regression analysis. Conclusion FDD is safe and effective in treating tandem aneurysms in the internal carotid artery with a high occlusion rate and few complications. TFD is comparable to PED in the treatment of intracranial tandem aneurysms.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Use of Pipeline Flex flow diverter in the treatment of an internal carotid artery Dissection: A case report
    Abouelleil, Mohamed
    Chehab, Ahmad
    Nabulsi, Omar
    Singer, Justin
    Mazaris, Paul
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2022, 29
  • [32] The fate of cranial neuropathy after flow diverter treatment of carotid aneurysms
    Brown, Ben
    Lopes, Demetrius
    Ringer, Andrew
    Powers, Oaran
    Sauvageau, Eric
    Arthur, Adam
    Hoit, Daniel
    Saenz, Hugo Cuellar
    Levy, Elad
    Siddiqui, Adnan
    Snyder, Kenneth
    Hopkins, L. Nelson
    Veznedaroglu, Erol
    Binning, Mandy
    Mocco, J.
    Brasiliense, Leonardo
    Miller, David
    Tawk, Rabih
    Hanel, Ricardo
    JOURNAL OF NEUROSURGERY, 2015, 122 (06) : A1552 - A1552
  • [33] Flow diverter manages very small aneurysm of the internal carotid artery
    Lee, Chien-Hui
    Luo, Chao-Bao
    Lai, Yen-Chun
    Chang, Feng-Chi
    Lin, Chung-Jung
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2022, 85 (07) : 754 - 758
  • [34] Angiographic assessment of the efficacy of flow diverter treatment for cerebral aneurysms
    Sadasivan, Chander
    Dholakia, Ronak
    Peeling, Lissa
    Goelitz, Philipp
    Doerfler, Arnd
    Lieber, Baruch B.
    Fiorella, David J.
    Woo, Henry H.
    INTERVENTIONAL NEURORADIOLOGY, 2019, 25 (06) : 655 - 663
  • [35] Flow Diverter Therapy Using a Pipeline Embolization Device for 100 Unruptured Large and Giant Internal Carotid Artery Aneurysms in a Single Center in a Japanese Population
    Oishi, Hidenori
    Teranishi, Kosuke
    Yatomi, Kenji
    Fujii, Takashi
    Yamamoto, Munetaka
    Arai, Hajime
    NEUROLOGIA MEDICO-CHIRURGICA, 2018, 58 (11) : 461 - 467
  • [36] Pipeline Embolization Device for Treatment of Extracranial Internal Carotid Artery Pseudoaneurysms: A Multicenter Evaluation of Safety and Efficacy
    Akinduro, Oluwaseun O.
    Gopal, Neethu
    Hasan, Tasneem F.
    Nourollah-Zadeh, Emad
    Vakharia, Kunal
    De Leacy, Reade
    Burkhardt, Jan-Karl
    Yamamoto, Junichi
    Mocco, J.
    Castilla, Leonardo Rangel
    Kan, Peter Tze Man
    Boulos, Alan
    Levy, Elad
    Tawk, Rabih G.
    NEUROSURGERY, 2020, 87 (04) : 770 - 778
  • [37] Comparative Efficacy of Flow Diverter Devices in the Treatment of Carotid Sidewall Intracranial Aneurysms: a Retrospective, Multicenter Study
    Dmytriw, Adam A.
    Salim, Hamza Adel
    Musmar, Basel
    Cancelliere, Nicole M.
    Griessenauer, Christoph J.
    Regenhardt, Robert W.
    Jones, Jesse
    Tutino, Vincent
    Hasan, Zuha
    Limbucci, Nicola
    Lay, Sovann V.
    Spears, Julian
    Rabinov, James D.
    Harrigan, Mark R.
    Siddiqui, Adnan H.
    Levy, Elad I.
    Stapleton, Christopher J.
    Renieri, Leonardo
    Cognard, Christophe
    Shaikh, Hamza
    Kuhn, Anna Luisa
    Moehlenbruch, Markus A.
    Tjoumakaris, Stavropoula I.
    Jabbour, Pascal
    Taussky, Philipp
    Settecase, Fabio
    Heran, Manraj K. S.
    Nguyen, Anh
    Volders, David
    Harker, Pablo
    Devia, Diego A.
    Puri, Ajit S.
    Psychogios, Marios
    Puentes, Juan C.
    Leone, Giuseppe
    Buono, Giuseppe
    Tarantino, Margherita
    Muto, Mario
    Briganti, Francesco
    Dalal, Shamsher
    Gontu, Vamsi
    Alcedo Guardia, Rodolfo E.
    Vicenty-Padilla, Juan C.
    Brouwer, Patrick
    Schmidt, Matthias H.
    Schirmer, Clemens
    Pickett, Gwynedd E.
    Andersson, Tommy
    Soderman, Michael
    Marotta, Thomas R.
    CLINICAL NEURORADIOLOGY, 2024, 34 (04) : 907 - 917
  • [38] Pipeline Embolization Device for Treatment of Extracranial Internal Carotid Artery Pseudoaneurysms: A Multicenter Evaluation of Safety and Efficacy
    Akinduro, Oluwaseun O.
    Gopal, Neethu
    Hasan, Tasneem F.
    Nourollah-Zadeh, Emad
    Vakharia, Kunal
    De Leacy, Reade
    Burkhardt, Jan-Karl
    Yamamoto, Junichi
    Mocco, J.
    Castilla, Leonardo Rangel
    Kan, Peter Tze Man
    Boulos, Alan
    Levy, Elad
    Tawk, Rabih G.
    NEUROSURGERY, 2021, 89 : S25 - S25
  • [39] Efficacy and Safety of Endovascular Treatment in Patients with Internal Carotid Artery Occlusion and Collateral Middle Cerebral Artery Flow
    Kim, Yong-Won
    Kang, Dong-Hun
    Kim, Yong-Sun
    Hwang, Yang-Ha
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2019, 62 (02) : 201 - 208
  • [40] Application of flow diverters in the treatment of aneurysms in the internal carotid artery bifurcation region
    Mahmoud, Mostafa
    Farag, Ahmed
    Farid, Mostafa
    Elserwi, Ahmed
    Abdelsamad, Amr
    Guergues, Wessam
    Hassan, Farouk
    NEURORADIOLOGY JOURNAL, 2020, 33 (04): : 297 - 305