Analysis of the safety and efficacy of flow diverter device in the treatment of tandem aneurysms in the internal carotid artery

被引:0
|
作者
Wan, Jun [1 ,2 ]
Xu, Ligang [2 ]
Jiang, Yeqing [3 ]
Zhang, Lei [2 ]
Wang, Zhenyu [2 ]
Zhang, Xiaolong [3 ]
Wang, Shengzhang [1 ,4 ]
机构
[1] Fudan Univ, Acad Engn & Technol, Shanghai, Peoples R China
[2] Fudan Univ, Jingan Dist Cent Hosp, Dept Intervent Radiol, Shanghai, Peoples R China
[3] Fudan Univ, Dept Radiol, Huashan Hosp, Shanghai, Peoples R China
[4] Fudan Univ, Inst Biomech, Dept Aeronaut & Astronaut, Shanghai, Peoples R China
来源
FRONTIERS IN NEUROLOGY | 2025年 / 16卷
关键词
intracranial aneurysms; tandem aneurysms; flow diverter device; pipeline; Tubridge; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT;
D O I
10.3389/fneur.2025.1462108
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective To investigate the clinical efficacy and safety of flow diverter device (FDD) in the treatment of tandem aneurysms in the internal carotid artery. Materials and methods This study was a retrospectively observational study involving two neurointerventional centers. Sixteen Patients with tandem aneurysms in the internal carotid artery treated with FDD and Digital Subtraction Angiography (DSA) follow-up in Huashan Hospital Affiliated with Fudan University and Jing'an District Central Hospital Affiliated with Fudan University from 2020.08 to 2023.12 were included. The outcomes included the angiographic occlusion rate of aneurysms, complications, and the modified Rankin Scale score. The risk factors of complete occlusion of tandem aneurysms were explored by logistic regression analysis. Results A total of 38 aneurysms were included, including 21 aneurysms of 8 patients in the Pipeline Embolization Device (PED) group and 17 aneurysms of 8 patients in the Tubridge Flow Diverter (TFD) group. A total of 16 FDD stents were implanted, 8 in each PED and TFD group, with a technical success rate of 100%. The median value of maximum aneurysm diameter (D-max) was 4.27 (3.57-5.41) mm. Among them, 28 aneurysms had a maximum diameter of <5 mm (73.7%), 10 aneurysms had a maximum diameter of 5-15 mm (26.3%). All patients were followed up clinically for a median of 25.5 months (15.5-28.7 months). There were no deaths and symptomatic complications. The modified Rankin Scale scores (mRS) of 16 patients were all less than 2. All patients were examined by angiography with a median of 14 months (6-27 months). Among them, there were 5 Consensus Grading Scale for Endovascular Aneurysm Occlusion (CGSFEAO) grade 5 (13.2%), 1 CGSFEAO grade 4 (2.6%), 1 CGSFEAO grade 2 (2.6%) and 31 CGSFEAO grade 0 (81.6%). The complete occlusion rate of intracranial aneurysm in the whole study was 81.6%, including 85.7% in the PED group and 76.5% in the TFD group, and there was no significant statistical difference between the two groups. Statistically significant variables were not found in univariate logistic regression analysis. Conclusion FDD is safe and effective in treating tandem aneurysms in the internal carotid artery with a high occlusion rate and few complications. TFD is comparable to PED in the treatment of intracranial tandem aneurysms.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Treatment of Tandem Internal Carotid Artery Aneurysms Using a Single Pipeline Embolization Device: Evaluation of Safety and Efficacy
    Adeeb, N.
    Moore, J. M.
    Griessenauer, C. J.
    Foreman, P. M.
    Shallwani, H.
    Dmytriw, A. A.
    Shakir, H.
    Siddiqui, A. H.
    Levy, E. I.
    Davies, J. M.
    Harrigan, M. R.
    Thomas, A. J.
    Ogilvy, C. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (08) : 1605 - 1609
  • [2] Flow Diverter Treatment for Non-Ruptured Carotid Aneurysms: Efficacy and Safety
    Lopez-Callejas, Orlando
    Ortiz-Giraldo, Andres F.
    Vera, Daniela D.
    Ramirez-Rojas, Diego A.
    Villamizar-Barahona, Ana B.
    Ferreira-Prada, Carlos A.
    Galvis, Melquizidel
    Vargas-Perez, Oliverio
    Serrano-Gomez, Sergio
    Reyes-Gonzalez, Adriana
    Mantilla, Daniel
    NEUROINTERVENTION, 2023, 18 (01) : 23 - 29
  • [3] Endovascular treatment of unruptured aneurysms of cavernous and ophthalmic segment of internal carotid artery with flow diverter device Pipeline
    Jevsek, Marko
    Mounayer, Charbel
    Seruga, Tomaz
    RADIOLOGY AND ONCOLOGY, 2016, 50 (04) : 378 - 384
  • [4] Flow diverter for endovascular treatment of intracranial mirror segment internal carotid artery aneurysms
    Kuhn, Anna Luisa
    Kan, Peter
    Srinivasan, Visish
    Rex, David E.
    Rodrigues, Katyucia de Macedo
    Howk, Mary C.
    Wakhloo, Ajay K.
    Puri, Ajit S.
    INTERVENTIONAL NEURORADIOLOGY, 2019, 25 (01) : 4 - 11
  • [5] Visual Outcomes with Flow-Diverter Stents Covering the Ophthalmic Artery for Treatment of Internal Carotid Artery Aneurysms
    Rouchaud, A.
    Leclerc, O.
    Benayoun, Y.
    Saleme, S.
    Camilleri, Y.
    D'Argento, F.
    Boncoeur, M. -P.
    Robert, P. -Y.
    Mounayer, C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) : 330 - 336
  • [6] Efficacy and Safety of Willis Covered Stent for Treatment of Internal Carotid Artery Aneurysms
    Tang, Chunhai
    Qi, Songtao
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (03) : E263 - E265
  • [7] Flow Diverter Treatment of Tandem Intracranial Aneurysms
    John, Seby
    Bain, Mark
    Cerejo, Russell
    Bauer, Andrew
    Masaryk, Thomas
    Hussain, Muhammad S.
    Rasmussen, Peter
    Toth, Gabor
    WORLD NEUROSURGERY, 2017, 107 : 142 - 147
  • [8] Flow diverter device for the treatment of small middle cerebral artery aneurysms
    Briganti, Francesco
    Delehaye, Luigi
    Leone, Giuseppe
    Sicignano, Carmine
    Buono, Giuseppe
    Marseglia, Mariano
    Caranci, Ferdinando
    Tortora, Fabio
    Maiuri, Francesco
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (03) : 287 - 294
  • [9] Innovations in Endovascular Treatment Strategies for Large Carotid Cavernous Aneurysms-The Safety and Efficacy of a Flow Diverter
    Miyachi, Shigeru
    Ohnishi, Hiroyuki
    Hiramatsu, Ryo
    Izumi, Takashi
    Matsubara, Noriaki
    Kuroiwa, Toshihiko
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2017, 26 (05): : 1071 - 1080
  • [10] Flow diverter stent treatment for unruptured supraclinoid segment internal carotid artery aneurysms: a Turkish multicenter study
    Yakar, Fatih
    Elbir, Cagri
    Civlan, Serkan
    Ulku, Goktug
    Keskin, Emrah
    Gel, Mehmet Selim
    Fesli, Ramazan
    Daltaban, Iskender Samet
    Bakirarar, Batuhan
    Aydin, Hasan Emre
    Kiraz, Ilker
    Ciltemek, Nazar
    Arici, Mustafa
    Acar, Feridun
    Coskun, Mehmet Erdal
    Turkoglu, Mehmet Erhan
    NEUROSURGICAL FOCUS, 2023, 54 (05)