Novel Pharyngeal Oxygen Delivery Device Provides Superior Oxygenation during Simulated Cardiopulmonary Resuscitation

被引:0
|
作者
Hanson, Jeramie B. [1 ,2 ]
Williams, John R. [2 ,3 ]
Garmon, Emily H. [1 ,2 ]
Morris, Phillip M. [1 ,2 ]
Mcallister, Russell K. [1 ,2 ]
Culp Jr, William C. [1 ,2 ]
机构
[1] Baylor Coll Med, Temple, TX USA
[2] Baylor Scott & White Med Ctr, Temple Dept Anesthesiol, Temple, TX USA
[3] Texas A&M Sch Med, Temple, TX USA
关键词
Advanced Cardiac Life Support; cardiopulmonary resuscitation; passive oxygenation; pharyngeal oxygen delivery device; supraglottic airway; CHEST COMPRESSIONS; CARDIAC-ARREST; ASSOCIATION; INTERRUPTIONS; DECOMPRESSION; INSUFFLATION; VENTILATION; SURVIVAL; EFFICACY;
D O I
10.1017/S1049023X24000542
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Passive oxygenation with non-rebreather face mask (NRFM) has been used during cardiac arrest as an alternative to positive pressure ventilation (PPV) with bag-valve- mask (BVM) to minimize chest compression disruptions. A dual-channel pharyngeal oxygen delivery device (PODD) was created to open obstructed upper airways and provide oxygen at the glottic opening. It was hypothesized for this study that the PODD can deliver oxygen as efficiently as BVM or NRFM and oropharyngeal airway (OPA) in a cardiopulmonary resuscitation (CPR) manikin model. Methods: Oxygen concentration was measured in test lungs within a resuscitation manikin. These lungs were modified to mimic physiologic volumes, expansion, collapse, and recoil. Automated compressions were administered. Five trials were performed for each of five arms: (1) CPR with 30:2 compression-to-ventilation ratio using BVM with 15 liters per minute (LPM) oxygen; continuous compressions with passive oxygenation using (2) NRFM and OPA with 15 LPM oxygen, (3) PODD with 10 LPM oxygen, (4) PODD with 15 LPM oxygen; and (5) control arm with compressions only. Results: Mean peak oxygen concentrations were: (1) 30:2 CPR with BVM 49.3% (SD = 2.6%); (2) NRFM 47.7% (SD = 0. 2%); (3) PODD with 10 LPM oxygen 52.3% (SD = 0.4%); (4) PODD with 15 LPM oxygen 62.7% (SD = 0. 3%); and (5) control 21% (SD = 0%). Oxygen concentrations rose rapidly and remained steady with passive oxygenation, unlike 30:2 CPR with BVM, which rose after each ventilation and decreased until the next ventilation cycle (sawtooth pattern, mean concentration 40% [SD = 3%]). Conclusions: Continuous compressions and passive oxygenation with the PODD resulted in higher lung oxygen concentrations than NRFM and BVM while minimizing CPR interruptions in a manikin model.
引用
收藏
页码:354 / 357
页数:4
相关论文
共 50 条
  • [41] The effect of positive end-expiratory pressure on cardiac output and oxygen delivery during cardiopulmonary resuscitation
    Levenbrown, Yosef
    Hossain, Md Jobayer
    Keith, James P.
    Burr, Katlyn
    Hesek, Anne
    Shaffer, Thomas
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2020, 8 (01)
  • [42] The effect of positive end-expiratory pressure on cardiac output and oxygen delivery during cardiopulmonary resuscitation
    Yosef Levenbrown
    Md Jobayer Hossain
    James P. Keith
    Katlyn Burr
    Anne Hesek
    Thomas Shaffer
    Intensive Care Medicine Experimental, 8
  • [43] Influence of Cardiopulmonary Resuscitation Coaching and Provider Role on Perception of Cardiopulmonary Resuscitation Quality During Simulated Pediatric Cardiac Arrest
    Cheng, Adam
    Kessler, David
    Lin, Yiqun
    Tofil, Nancy M.
    Hunt, Elizabeth A.
    Davidson, Jennifer
    Chatfield, Jenny
    Duff, Jonathan P.
    Brown, Linda
    Nye, Megan
    Gaither, Stacy
    Collier, Holly
    MacKinnon, Laura
    Lowe, Katherine
    Lambert, Viktoriya
    PEDIATRIC CRITICAL CARE MEDICINE, 2019, 20 (04) : E191 - E198
  • [44] Vasopressors are essential during cardiopulmonary resuscitation in rats:: Is vasopressin superior to adrenaline?
    Popp, Erik
    Vogel, Peter
    Teschendorf, Peter
    Boettiger, Bernd W.
    RESUSCITATION, 2007, 72 (01) : 137 - 144
  • [45] Caesarean delivery during maternal cardiopulmonary resuscitation for status asthmaticus
    Lurie, S
    Mamet, Y
    EMERGENCY MEDICINE JOURNAL, 2003, 20 (03) : 296 - 297
  • [46] Renal oxygen delivery during cardiopulmonary bypass
    Morrice, D.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (03) : 430 - 430
  • [47] Quantifying force application to a newborn manikin during simulated cardiopulmonary resuscitation
    Solevag, Anne Lee
    Cheung, Po-Yin
    Li, Elliott
    Aziz, Khalid
    O'Reilly, Megan
    Fu, Bo
    Zheng, Bin
    Schmoelzer, Georg
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (11): : 1770 - 1772
  • [48] Comparison of the UEScope videolaryngoscope with the Macintosh laryngoscope during simulated cardiopulmonary resuscitation
    Szarpak, Lukasz
    Madziala, Agnieszka
    Czekajlo, Michael
    Smereka, Jacek
    Kaserer, Alexander
    Dabrowski, Marek
    Madziala, Marcin
    Yakubtsevich, Ruslan
    Ladny, Jerzy Robert
    Ruetzler, Kurt
    MEDICINE, 2018, 97 (36)
  • [49] The LMA Fastrach® as a conduit for endotracheal intubation during simulated cardiopulmonary resuscitation
    Smereka, Jacek
    Szarpak, Lukasz
    Ladny, Jerzy R.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (07): : 1020 - 1021
  • [50] Magnetically targeted drug delivery during cardiopulmonary resuscitation and the post-resuscitation period
    Xanthos, Theodoros
    Chatzigeorgiou, Michael
    Johnson, Elizabeth O.
    Chalkias, Athanasios
    RESUSCITATION, 2012, 83 (07) : 803 - 805